• Title/Summary/Keyword: 공기오염물질

Search Result 366, Processing Time 0.027 seconds

공기조화기의 IAQ 댐퍼 유닛 소개

  • Kim, Du-Seong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.3
    • /
    • pp.14-17
    • /
    • 2010
  • 실내공간의 필터로도 제거되지 않는 미세한 오염물질 때문에 적절한 외기 도입은 필수적이다. 이에 한미설비(주)에서는 소비자들의 욕구에 합당하는 실내환경을 유지하기 위한 장치의 하나인 IAQ 댐퍼 유닛을 개발하였고 이를 소개하고자 한다.

  • PDF

Permeation Characteristics of the Tubular Membrane Module Equipped wtih the Air Injection Nozzle Tube (공기주입 노즐관이 장착된 관형막의 투과특성)

  • Park, Mi Ja;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.27 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • The air injection nozzle tube was inserted inside of the tubular membrane module to reduce membrane fouling and improve the permeate flux. The average pore size of membrane was $0.1\;{\mu}m$ and the yeast was used as a foulant. All of permeate experiments were started without air injection for the module equipped with the nozzle tube, then carried out continuously with air injection. Finally, the nozzle tube was removed from the module and the permeate was measured without air injection. The measured permeate fluxes were compared to examine the effect of air injection. The fluxes for air injection were consistently maintained or increased. The fluxes of no-air injection with the nozzle tube were greater than those of the empty tubular module. As operating pressure decreased to 0.4 bar, the flux enhancement of air injection based on no-nozzle case increased to 21%. Flux enhancements of air injection were above 30% as the gas/liquid two-phase flow was changed from the stratified-smooth to the intermittent pattern due to increase of gas flowrate.

The In-Situ Ozone Oxidative Remediation Potential of Diesel Fuel-contaminated Soil (디젤오염토양에 대한 지중 오존산화처리 적용 가능성)

  • 유도윤;신응배;배우근
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.3-15
    • /
    • 1999
  • This paper includes the basic experimental results performed for developing an innovative and technologically feasible process wherein gaseous ozone, a powerful oxidant. is injected directly into vadose zone by which in-situ chemical degradation of semi- or, non-volatile petroleum product such as diesel fuel is derived. As ozone gas injected continuously(50mL/min, 119.0$\pm$6.1mg/L) into soil packed columns artificially contaminated with diesel fuel(initial concentration 1,485mg-DRO/kg/soil), the removal rates at the inlet and outlet point of 14hrs-operated column are 87.9% and 100.0%, respectively. On the other hand, soil vapor extraction system showed less than 30% of removal rates of residual diesel both at the inlet and outlet samples under the same experimental conditions which confirms the limited treatability of SVE in diesel contaminated soil.

  • PDF

보호막 내 불순물 확산 방지를 통한 AC PDP 의 방전 효율 개선

  • Jeong, Hui-Un;Lee, Tae-Ho;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.487-487
    • /
    • 2012
  • 플라즈마 디스플레이 패널(PDP)은 공정 절차가 간단하고 가격 경쟁력이 매우 뛰어나 일찌감치 대형 평판 디스플레이 시장을 주도해 왔으며 빠른 응답 속도를 기반으로 한 생생한 화질의 구현으로 3D TV 시장에서도 꾸준한 사랑을 받고 있다. 향후 더 큰 화면을 요구하는 PID(Public Information Display) 시장에서도 PDP 는 두각을 나타낼 수 있을 것으로 보인다. 하지만 PDP 는 여전히 LCD, OLED 등의 디스플레이에 비해 발광 효율이 낮고 소비 전력이 높다는 단점을 가지고 있다. 또한 미국 환경청(EPA)과 에너지부(DOE)가 공동으로 마련한 전자 제품의 효율 등급제인 에너지 스타(Energy Star) 제도가 끊임없이 개편되면서 소비 전력에 대한 규제가 점차 강화되고 있기 때문에 발광 효율 및 소비 전력 특성의 개선은 현재 PDP 업계가 해결해야 할 가장 중요한 과제라고 할 수 있다. 발광 효율의 개선과 관련하여 최근에는 PDP의 보호막으로 널리 쓰이고 있는 MgO 보다 2차 전자 방출 계수가 높아 PDP의 구동 전압을 낮추는 동시에 휘도와 발광 효율 특성을 개선시킬 수 있는 신 보호막에 대한 연구가 활발히 이루어지고 있다. MgO를 대체 가능한 신 보호막으로 언급되는 물질은 SrO 혹은 CaO 등이 대표적이다. 하지만 이러한 물질들은 공기 및 수분에 대한 용해도가 높기 때문에 증착된 막이 이후의 공정 과정(합착 및 가열 배기 등)에서 대기 중에 노출 될 경우 심하게 변질될 수 있다. 이러한 문제점을 해결하기 위해서 신 보호막 위에 기존의 MgO 보호막을 얇게 증착하여 공기로부터의 접촉을 차단하거나 펠렛을 제조하는 과정에서 MgO 에 신 보호막 물질을 소량만 첨가하는 등의 방법들이 제안되어 왔으며 그 결과 기존의 PDP 대비 구동 전압을 낮추고 발광 효율을 획기적으로 개선하는데 성공한 결과들이 지속적으로 보고되고 있다. 하지만 신 보호막이 공기 및 수분에 민감한 만큼, 고온의 공정으로 인해 PDP의 하판 유리로부터 상판에 증착된 박막으로 확산되는 불순물에 의해서도 오염되며 이 역시 신 보호막의 특성을 구현하는데 방해 요소로 작용한다. 본 연구에서는 PDP 하판의 불순물이 상판의 박막으로 확산되는 것을 방지하고자 하판 형광체 인쇄전 PECVD 증착법으로 확산 방지막을 1 가량 형성하였다. 이후 SIMS 분석을 통하여 하판 불순물의 확산이 효과적으로 차단됨을 확인하였고 신 보호막의 오염을 최소화하여 결과적으로 PDP의 구동 전압을 낮추고 효율을 획기적으로 개선하는데 기여할 수 있음을 확인하였다.

  • PDF

A Study on the Effect of Photocatalyst Coating to Improve the Indoor Air Quality in Buildings (건축물 실내 공기질 향상을 위한 광촉매 코팅 효과에 관한 연구)

  • Park, Hyeon-Ku;Kim, Jong-Ho;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.150-157
    • /
    • 2006
  • Sick Building Syndrome (SBS) is an illness symptom such as irritation of eyes, skin eruption and vomit ing in newly constructed buildings. It is mainly due to the harmful gases from the materials installed in building such as Volatile Organic Compounds (VOCs), Semivolatile Organic Compounds (SVOCs), floating bacteria, fungi, fungal spores and viruses, human bioeffluents in many modem buildings. The general ways to improve the Indoor Air Quality (IAQ) are ventilating, utilizing eco-material without harmful gases and reducing or removing harmful gases through additional treatment to the building materials. This study aimed to improve the Indoor Air Quality(IAQ) by applying surface coating on the building materials and to make safe living environments through the analysis of air quality before and after surface coating treatment in buildings.

Development of an Economic Assessment Model for the Selection of Indoor Air Pollutant Low Emission Material for G-SEED (G-SEED용 실내공기 오염물질 저방출 자재 선정을 위한 경제성 평가 모델 개발)

  • Kwon, Seong-Min;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.289-296
    • /
    • 2021
  • The Korean construction industry has been implementing G-SEED, a certification system that evaluates the environmental properties of buildings for the purpose of reducing environmental burdens such as energy and resource consumption and pollutant emissions. Also, creating a pleasant environment in general is one more purpose of G-SEED certification system. However, G-SEED certification in practice is difficult and time consuming due to the complexity of the certification acquisition process coupled with little economic consideration for the materials of each certification item. Therefore, in this study, we present a model for the optimal selection of materials and economic assessment using a genetic algorithm. The development of the model involves building a material database based on life-cycle costing (LCC) targeted at "Application of Indoor Air Pollutant Low Emission Material" from G-SEED. Next, the model was validated using a real non-residential building case study. The result shows an average cost reduction rate of 74.5 % compared with the existing cost. This model is expected to be used as an economically efficient tool in G-SEED.

Assessment of Indoor Radon Pollution from Underground Water (지하수로부터의 라돈 실내오염 평가)

  • 유동한;김상준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.130-131
    • /
    • 2000
  • 라돈(Rn-222)은 우라늄(U-238) 방사능계열의 원소로서 라듐(Ra-226)의 붕괴시 자연생성되는 가스상 물질이다. 화학적으로는 불활성이며 무색, 무취의 특성을 가지고 있다. 공기보다 8∼9배 무겁기 때문에 지표면 가깝게 존재하므로 인체노출이 쉬운 물질로 알려져 있다. 라돈은 최근까지도 온천 등지에서 건강에 매우 좋은 원소로 알려져 왔으나 사실은 기준치 이상의 라돈을 마시거나 호흡했을 경우, 치명적인 폐암을 유발시킨다는 것이 밝혀졌다(Doull et al, 1999) (중략)

  • PDF

Evaluation Fugitive Emission Characteristics of Airbone VOCs from Different Source Categories (발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출특성 평가)

  • 김배갑;백성옥;김미현;서영교;정복채
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.245-246
    • /
    • 2002
  • 일반적으로 대기 중 환경기준을 제어하기 위해서는 각 배출원에서 발생되는 오염물질의 배출강도를 정량적으로 평가 할 필요가 있다. 최근 들어, 휘발성 유기화합물질의 환경학적 중요성이 밝혀지면서 이 물질에 대한 대기 중 농도분포는 어떤 양상을 보이며 이에 영향을 미치는 각 배출원에서 비산배출(fugitive emission)되는 VOCs 종류와 농도에 대한 조사가 필요하게 되었다. VOCs 배출원은 모든 국가가 유사하겠으나 배출원별 VOCs의 배출기여도는 각국의 경제 및 산업구조의 특성에 따라 달라질 수 있다. (중략)

  • PDF

A Study on the Entrance Region Fouling of Sludge Incinerator Air-preheater at IronWorks (제철슬러지 소각로의 공기예열기 입구의 파울링특성 연구)

  • 박상일;김정근
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.557-562
    • /
    • 2003
  • 산업체 소각로의 고온 배가스에는 소각물질의 특성에 따라 다양한 성분의 오염물질이 함유되어 있다. 고온 소각배가스의 후처리를 위하여 배가스냉각용 열교환기가 사용되고 있다. 그러나, 소각로 열교환기의 입구와 전열면에 파울링 현상이 발생하여 열교환기의 전열성능이 감소하고 또한 심한 경우, 유로면적이 줄어들어 통풍저항이 증대된다.(중략)

  • PDF