• Title/Summary/Keyword: 공기분배시스템

Search Result 25, Processing Time 0.023 seconds

Study of Tolerance Suitability of Door Operation Mechanism on Mobile Air Handing Unit Using 3-DCS Analysis (3-DCS를 이용한 자동차 공기 분배장치의 도아 구동 기구의 공차 적합성 분석에 대한 연구)

  • Kim, Jongsu;Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.527-537
    • /
    • 2016
  • Recent automakers are trying to be more precise with the dimension check and moving parts to guarantee high quality and satisfy customer requirements. The aim of this paper is to investigate the design tolerance suitability of door operating mechanism linked arms, lever, and cam-shaft in a mobile air handling unit. These parts are complicated because doors, arms, lever and cam-shaft are connected nonlinearly in 3D. The current tolerance analysis method poses problems in design analysis because the moving doors are reasonably suitable for the AHU function. The 3-DCS analysis method provided useful results not only in establishing the inspection criteria for the quality control of products but also in enabling economical production. As a result, the vent door had $1.62^{\circ}{\sim}1.72^{\circ}$ and the defrost door had $0.84^{\circ}{\sim}0.9^{\circ}$ for the directly connected arms operating-type. For the lever connected arm operating-type, the foot door had $2.0^{\circ}{\sim}2.24^{\circ}$ tolerance, while the tolerance values satisfied the air flow volume distribution rate criteria in the AHU. Finally, the results have confirmed the design's tolerance suitability by using 3-DCS analysis at the early design stages. Reliability can be achieved by analyzing accumulated tolerance during the sub-parts assembly process and the moving mechanism linked especially by arms, lever, and cam-shaft.

A Study on Thermal Management of Stack Supply Gas of Solid Oxide Fuel Cell System for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 시스템의 스택 공급 가스의 열관리 문제에 관한 연구)

  • Park, Sang-Kyun;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.765-772
    • /
    • 2011
  • In this research, the fuel cell system model capable of generating codes in real time was developed to construct of a HIL (Hardware-In-the-Loop) for a SOFC-powered ship. Moreover, the effects of the distribution of the exhaust gas flow rates in a stack, the flow rates of fuels and temperature of air supplied on the temperature characteristics of fuels supplied to the cathode and the anode, the output power of the stack and system efficiency are examined to minimize the temperature difference between fuels supplied to the stack used in a 500kW SOFC system using methane as a fuel. As a result, the temperatures of fuels supplied to the cathode and the anode maintain at 830K when the opening factor of three-way valve located at outlet of turbine is 0.839. Also the process for optimization of methane flow rate considering the fuel cell stack and system efficiency is required to increase the temperatures of fuels supplied to the stack.

Ventilation and energy performance evaluation of the office building with variable air volume system (변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가)

  • Kwon, Y.L.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF

Basic Operational Characteristics for Developments of Solar Air Heater for Air Heating in Winter (태양열 이용 난방용 공기가열기 개발을 위한 기초 운전 특성)

  • Kim, Jong-Ryeol;Hong, Boo-Pyo;Woo, Jong-Soo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.87-94
    • /
    • 2011
  • To develop the solar air heater, prototype of solar heater with test room set up on the roof of test chamber and operation characteristics were examined with solar radiation. Air induced from outside was supplied by a blower and also heated air was supplied to the test chamber(size of 1,000mm(inwidth)*2,000mm(in length)*2,000mm(in depth)) established already for performance. It was clear that almost 30% of solar radiation was converted into effective heating energy at maximum and the highest air temperature was $46^{\circ}C$, and thus solar air heater in winter could be used as an possible alternative heating system in building. Furthermore, heat energy obtained from solar air heater can be applied to regenerate absorber in the solar desiccant cooling system.

Enhanced Removal of Benzene-NAPL in Soil using Concurrent Injection of Cosolvent and Air (Cosolvent와 공기 동시 주입 공정에 의한 토양 내 벤젠-NAPL 세정 증대 연구)

  • Song, Chung-Hyun;Jeong, Seung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1095-1101
    • /
    • 2008
  • Nonaqueous phase liquids (NAPL) are the continuous source for soil and groundwater contamination. The first objective of the study was to verify the effect of co-injection of cosolvent and air on NAPL removal from soil-column system. The second objective of the study was to investigate the effect of alcohol-partitioning property on the NAPL removal by the co-injection process of cosolvent and air. Enhanced removal of benzene-NAPL by the co-injection process of ethanol and air was also verified within the soilcolumn system. However, the co-injection process of Tert-butanol (TBA) and air showed no enhancement of benzene-NAPL removal. This study found that the viscous pressure of TBA was so higher than the capillary pressure and TBA easily displaced the benzene-NAPL and air present in soil pores. Air of the coinjection process did not work for NAPL removal but hindered NAPL mobilization. NAPL partitioning property and viscous pressure of cosovlent should be considered for application of the co-injection process of cosolvent and air.

Development of air-conditioning and drinking water supply system using air-water heat pump (공기-물 히트펌프를 이용한 공조 및 음용수급수시스템 개발)

  • Paek, Yee;Kang, Sukwon;Jang, Jae-Kyung;Kim, Young-Hwa
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.118-118
    • /
    • 2017
  • 지구 온난화에 따른 환경변화로 인하여 최근 10년('02~'11)간 여름의 일수는 4일, 겨울 일수는 16일 각각 증가하였다. 현재 육계사 내의 고밀도 밀집사육으로 인하여 고온스트레스로 하절기 육계의 폐사율이 증가하고 있는 실정이다. 2016년 폭염으로 닭 406.1천수, 오리 15.7천수, 메추리 70천수, 돼지 8천수가 폐사하였다. 이에 혹서기 가축이 약430만수가 폐사하였으며 피해 보상금액 128억원 소요되었다. 본 연구에서는 하절기 고온스트레스 경감과 폐사율 저감을 위해 계사 냉난방 공조와 냉온 음용수 급수를 병행할 수 있는 고효율 환경 개선 시스템을 개발하여 고온스트레스 저감 및 생산성 향상에 목적이 있다. 계사 냉난방 공조 및 냉온음용수 급수 병행 시스템 설계요인을 분석하고 냉난방 공조부하, 냉온수 생산 부하를 고려한 시스템 용량 산정하고 히트펌프, 축열조, 냉난방 및 냉온수 분배장치 등 구성요소로서 공조 및 냉온음용수 급수시스템을 설치하였다. 시스템 용량은 공기-물 히트펌프(10kW,1대), 축열조(10톤), 음용수조(2톤), 열교환기(열교환량,5만kcal/h), 물순환펌프(250W,2대) 및 팬코일유닛(1만kcal/h,4대)으로 시스템 모니터링 및 제어 시스템 개발하여 계사 내 환경, 시스템 성능에 대한 실시간 모니터링을 통하여 저장하였다. 조사항목으로 위치별 온습도, 체중, 사료섭취량, 페사율 등을 조사 분석하였다. 연구결과 계사의 내부온도는 시험구에서는 평균 $25.3^{\circ}C$를 나타내었고 대조구에서는 평균 $28.1^{\circ}C$로서 $2.8^{\circ}C$ 높게 나타났으나 상대습도는 시험구 76.2%, 대조구 75.0%로 큰 차이가 없었다. 냉수급여에 따른 계사 높이별 내부온도는 상하의 온도차가 $4.5^{\circ}C$로 크게 차이가 났다. 육계의 음수량은 혹서기 냉수를 급여한 시험구에서 일일 23.2L, 대조구에서는 21.5L를 섭취하였다. 일일 사료섭취량은 냉수를 급여한 시험구에서 937g, 대조구에서는 725g을 섭취하였다. 사료섭취량은 냉수를 급여한 시험구가 212g 많이 섭취하였으며 사료요구율은 시험구는 1.86, 대조구는 1.91로서 시험구가 낮게 나타났다. 체중은 냉수를 급여한 시험구가 359g 많았으며 증체량은 냉수를 급여한 시험구에서 495g, 대조구에서는 392g으로 나타났다. 폐사율은 냉수를 급여한 시험구에서 84%가 폐사율을 줄일 수 있었다.

  • PDF

A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository (지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰)

  • Kim, Young-Min;Kwon, O-Sang;Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.65-78
    • /
    • 2007
  • The pollutants (Rn, CH, CO, HS, radioactive gas from radiolysis) were generated from the process of construction and operation of underground repository, and after disposal of low-intermediate radioactive waste inside there must be controlled by a ventilation system to distribute them in area where enough air is supported. Therefore, a suitable technical approach is needed especially at an underground repository that is equipped with many entry tunnels, storage tunnels, exhaust-blowing tunnels, and vertical shafts in complicated network form. For the technical approach of such a ventilation system, WIPP (Waste Isolation Pilot Plant) in U. S and SFR (Slutforvar for Reaktorafall) low-intermediate radioactive waste repository in Sweden were selected as the models, for calculating the required air quantity, organizing a ventilation network considering cross section, length, surface roughness of the air passage, and describing a calculation of resistance of each circuit. Based on these procedures, a best suited ventilation system was completed with designing proper capacity of fans and operating plan of vertical shafts. As a result of comparing the two repositories based on the geometry dimensions and ventilation facility equipment operation, more parallel circuit as in WIPP, brought decrease in resistance for entire system leading to reduce of operating costs, and the larger cross-sectional area of the SFR, the greater the percentage of disposal capacity. Accordingly, the mixture of parallel circuit of WIPP repository for reducing resistance and SFR repository formation for enlargement of disposal capacity would be the most rational and efficient ventilation system.

  • PDF

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I))

  • Kwon, Young-Hyun;Kim, Jin-Uk;Jung, Yu-Jin;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4656-4663
    • /
    • 2010
  • In this study, the 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics, flow distribution, air mean ages, and residence time for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. In addition, it showed the possibility that the velocity field and distribution characteristics of the residence time could be improved through a modification to inlet structure of the spray dryer reactor. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, the installation area, the operation fee, and management more convenient.

Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC (2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가)

  • Kim, Young Bae;Kim, Eun Ju;Yoon, Jonghyuk;Song, Hyoungwoon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.62-67
    • /
    • 2019
  • This study was focused on the design and the performance analysis of integral Hot BoP for recovering waste heat from high-temperature exhaust gas in 2 kW class solid oxide fuel cell (SOFC). The hot BoP system was consisted of a catalytic combustor, air preheater and steam generator for burning the stack exhaust gas and for recovering waste heat. In the design of the system, the maximum possible heat transfer was calculated to analyze the heat distribution processes. The detail design of the air preheater and steam generator was carried out by solving the heat transfer equation. The hot BoP was fabricated as a single unit to reduce the heat loss. The simulated stack exhaust gas which considered SOFC operation was used to the performance test. In the hot BoP performance test, the heat transfer rate and system efficiency were measured under various heat loads. The combustibility with the equivalent ratio was analyzed by measuring CO emission of the exhaust gas. As a result, the thermal efficiency of the hot BoP was about 60% based on the standard heat load of 2 kW SOFC. CO emission of the exhaust gas rapidly decreased at an equivalent ratio of 0.25 or more.

Analysis of the Influence of Job Satisfaction and the Performance-oriented Remuneration in Electric Power Companies on Trust in Manager: Focusing on the Mediating Effect of Organizational Justice (전력공기업의 직무만족과 성과보수가 경영자신뢰에 미치는 영향관계에서의 조직공정성의 매개효과 검증)

  • Leen, Jae-Mahn
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.5
    • /
    • pp.143-158
    • /
    • 2021
  • The purpose of this study is to suggest a direction for enhancing the mutual trust level between employees and managers by examining the effect of job satisfaction of electric power companies's employees and performance-oriented remuneration paid to them on awareness level of organizational justice and a trust in manager. Based on a significant positive relationship between employee's job satisfaction and trust in a manager, a significant positive relationship between employee's job satisfaction and perception of organizational justice, and a positive relationship between organizational justice and trust in manager, it was possible to confirm the mediating role of organizational justice between job satisfaction and a trust in manager. In addition, although performance-oriented remuneration did not have a significant effect on trust in manager directly, it was found to have a significant negative effect on distributive justice and procedural justice, but for interactional justice did not appear to have a significant influence. Because the autonomy of the labor budget is quite limited due to the government's total regulation on the size of the labor budget for public enterprises and due to the government's evaluation of management of public enterprises, it can be explained as having a negative effect on the perception of organizational justice. In addition, since the partial mediating effect of distributive justice and interactional justice was confirmed in the relationship between job satisfaction and trust in manager, the mediating effect of procedural justice was insignificant, it was confirmed that the need to establish and operate an internal HR management system based on smooth communication that employees can satisfy and accept can have a significant impact on trust in manager. On the other hand, because the negative complete mediating effect of distributive justice and procedural justice between performance-oriented remuneration and trust in manager was significantly confirmed, It is showing that employees' negative perceptions of performance distribution procedures and distribution results had a negative effect on trust in manager. The results of this study suggest that employees will perceive the organization as fair, and trust the manager who is the decision maker, when they are fully rewarded for their performance, with job satisfaction, a fair evaluation of their efforts, even if there are various factors that can influence managers to be trusted by their employees.