• Title/Summary/Keyword: 공기공급

Search Result 743, Processing Time 0.027 seconds

The Study of Performance Comparison on the Inlet Shapes of Fan for Engine Room of Ship Using CFD (CFD를 이용한 선박 기관실 공기 공급용 팬 입구 형상에 따른 성능 비교 연구)

  • Kwon, Do-Hoon;Hong, Youn-Gyun;Koo, Seong-Woo;Jeong, Eun-Soo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.25-31
    • /
    • 2011
  • The performance of fan for engine room of ship is absolutely important when it take into consideration work efficiency, work condition, and the performance of various equipments. Fan performance test should be carried out during sea trial to satisfy owner's requirement as above mentioned. We have considered various values to affect fan test result. In here, various values are to be silencer, fan inlet shape, and arrangement of fan room. In general, the shapes of fan inlet is overall circular type because of the shapes of axial fan. So, all vessels built at SHI have been applied fan inlet of circular type. And now, in order to reduce sound of noise from supply fan, big silencer often has been installed at high value vessels. In this case, the capacity of supplied air can be insufficient due to silencer which is an obstructer about air flow. In this paper, we have studied the performance of fan through comparison between a circular shape and a square shape of fan inlet. We also compare with CFD results and experimental results.

  • PDF

수돗물의 절약과 수요관리에 대한 고찰

  • 이현동
    • Water for future
    • /
    • v.33 no.5
    • /
    • pp.61-69
    • /
    • 2000
  • 물은 인간생활에 가장 필수적인 재화이며, 모든 산업의 기본이다. 더욱이 다른 재화와는 달리 대체재가 없다는 것에 그 심각성이 있다. 인구의 폭발적인 증가와 급격한 산업화로 지구촌의 물 부족 현상은 이미 어제 오늘의 일이 아니다. 최근 일부지역에서는 물전쟁 시나리오까지 등장하고 있다. 최근 40년간 세계의 물 소비량은 3배나 증가하였으며, 국가간 물 분쟁도 증가 추세를 보이고 있다. 우리 나라의 경우도 연평균강수량(1.27mm)이 세계평균(973mm)의 1.3배에 이르고는 있지만, 높은 인구 밀도 때문에 1인당 연간 평균강수량은 세계평균의 12.5%에 불과한 실정이다. 또한, 실질적으로 사용 가능한 자원량을 생각하면 문제는 더욱 심각하다. UN의 국제인구행동연구소(PAI:Population Action International)의 발표에 따르면, 우리 나라의 활용 가능한 자원량은 661억$m^3$으로 이를 국민 한사람당으로 환산해 보면 1.472$m^3$으로 물 부족 국가군에 해당한다. 현재 건설교통부의 수자원장기종합계획에 의하면, 우리 나라는 2006년부터 연간 4억$m^3$, 2011년부터 연간 20억$m^3$의 물이 부족할 것으로 전망하고 있다. 우리 나라 수자원 특성상 물을 확보하는데는 댐 건설 등 수자원시설이 적기에 건설되어야 하지만, 공기가 길고(10년 이상 소요), 엄청난 투자비(약 24조원), 수몰지 발생, 환경변화 등 많은 문제점들이 도출되고 있다. 그러나 미래의 물 부족에 대응하기 위해서 댐 건설(상수원전용 댐)은 불가피한 대안 중의 하나이다. 또 다른 대안으로는 교육이나 홍보를 통하여 수돗물 사용자로 하여금 자발적으로 물 사용량을 줄이도록 권고하는 방법이 있다. 또한 수도요금체계를 현실화시키거나 법규를 통하여 절수를 의무화하는 등의 방법을 통하여 물 수요를 관리하여 댐 건설이나 상수도시설 확장 등 많은 예산이 소요되는 공사를 실시하지 않고서도 급수관리와 비슷한 효과를 가질 수도 있다. 따라서 물 절약 등 수요관리를 통하여 용수수요를 줄여 나가는 방안 마련이 시급하다. 그리고 물은 한정된 자원이자 우리의 생명수이다. 이제는 수요가 증가한다고 해서 무턱대고 공급을 늘이기 위한 정책 방향으로만 갈 수는 없는 실정이다 보니 물 수요관리를 더 한층 중요하게 다루어야 할 적기가 바로 오늘이 시점부터라고 할 수 있다.

  • PDF

Solid-Liquid Separation Characteristics with Bio-filter Media Reactor (여과분리형 생물반응조의 고액분리 특성)

  • Park, Young Bae;Jung, Yong Jun
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.347-353
    • /
    • 2014
  • This work was performed to find the effect of operation parameters on the permeate flux through the activated sludge dynamic layer, and to indicate the relationship between the water quality of supernatant and flux based on the results. Since the effluent can be obtained through steady and stable formation of cake layer in the bio-filter media system, it is an important subject to keep and control microbes with activated state in the bio-reactor. Filtration resistance was drastically increased at more than 18000mg/L of MLSS. With filtration time continued, the flux was gradually decreased and the water qualities of supernatant monitored by turbidity and TOC were also deteriorated. This phenomenon indicated that the organic materials generated by microbes and accumulated in the reactor might affect the flux in the system. In addition, the decrease of flux was simultaneously observed in the sludge volume index. When SVI was controlled from 150 to 250, the flux was also decreased. The proper aeration time was recommended to 30 to 60 seconds in this system. In order to operate this system steadily, therefore, the control of water quality of supernatant and SVI should be proceeded.

Control of Thermal Crack in Mass Concrete Using Automated Curing System (양생자동화 시스템을 이용한 매스 콘크리트 온도균열 제어)

  • Ha, Ju-Hyung;Cho, Yun-Gu;Hyun, Tae-Yang;Lim, Chang-Keun;Seo, Tae-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.195-200
    • /
    • 2013
  • New thermal crack control system for mass concrete was developed to increase quality and to save construction period and cost. The principle of this system is that the curing water having proper temperature is supplied automatically to the surface of mass concrete member to keep the temperature difference between center and surface of concrete less than generally recommended temperature difference ($20^{\circ}C$). Mock-up test was conducted to investigate the validity of newly developed curing system. As a result, no crack was founded in the specimen using automated curing system developed in this study, while many cracks occurred in another specimen without automated curing system. It was also confirmed that the strength and the durability of the concrete cured by automated curing system were improved.

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

Epidemiological Studies of Blast Disease of Rice Plant II. Significance of Differential Distribution of Leaf Lesions at Different Location of Each Tiller as an Inoculum Source of Panicle Blast (수도 도열병의 역학적 연구 II. 이삭 도열병 전염원으로서의 엽위별 병반분포의 의의)

  • Park J.S.;Yu S.H.;Kim H.G.
    • Korean journal of applied entomology
    • /
    • v.22 no.4 s.57
    • /
    • pp.277-282
    • /
    • 1983
  • Number and percentage of diseased area of leaf blast lesions formed on different leaf location were mostly distributed from the flag leaf(n-1) to the 3rd leaf from the top(n-3) in Tongil line rice varieties and on the 2nd leaf from the top(n-2) in Japonica type rice varieties. Especially leaf lesions of Nopung which was more susceptible to leaf blast among Ton1 line rice varieties were mostly distributed on flag leaf. Relation between the degree of lesion distribution and level of fertilizer was more clear with an increase of fertilizer quantity. Leaf blast lesions of rice varieties were generally distributed from the flag leaf to the with leaf from the top but mainly those at flag leaf and the 2nd leaf from the top were found to be most responsible for inoculum source of panicle blast after booting stage. Increase of the conidia formation was resulted from fluctuation of temperature$(24^{\circ}C\~16^{\circ}C)$ in low temperature range after booting stage and many inoculum sources were supplied on panicles until the end of September without impeding dispersal from leaf blast lesions as an inoculum source of panicle blast.

  • PDF

An Experimental Study of Evaporative Heat Exchangers with Mini-channels (물의 증발잠열을 이용하는 미니채널 열교환기의 실험적 연구)

  • Lee, Hyung-Ju;Yoo, Young-June;Min, Seong-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.245-253
    • /
    • 2010
  • The present study shows some results of developing evaporative heat exchangers with mini-channels. Heat exchangers with three different water paths were manufactured and tested to compare performances of cooling and pressure drop. Among the three types of heat exchangers, Type 2 with full-etching was proved to be the best in the cooling performances for considered operating conditions, and thus it is recommended to adopt Type 2 for its simplicity of production and outstanding performance. However, Type 1 was shown to be better when it is operated at a high air inlet temperature condition. The developed evaporative heat exchanger will be installed in Environmental Control Systems(ECSs) for aerial vehicles, and it can be used effectively in case an ECS is not only limited in its weight and volume but also required to absorb heats without supplying water (or a coolant) for a certain period of time.

  • PDF

Float Zone Growth of Superconduction $Bi_2Sr_2CaCu_2O_8$ Fiber with Halogen Lamp (할로겐 램프 열원을 이용한 초전도성 $Bi_2Sr_2CaCu_2O_8$ Fiber의 Float Zone 성장)

  • 김철진;정준기
    • Korean Journal of Crystallography
    • /
    • v.7 no.2
    • /
    • pp.147-155
    • /
    • 1996
  • Floating Zone Image furnace with halogen lamps as heat source has been made and applied to the growth of high-Tc superconductor Bi2Sr2CaCu2O8. The manufactured crystal growth equipment is composed of holder unit for setting the halogen lamps at the focal point of the elliptical mirror, image furnace with maximum temperature of 1800℃ with 1kW halogen lamps, cooling unit, feeding unit for supplying source material to the molten zone, pulling unit for crystal growth, and the control unit in the range of 2mm/hr -40 mm/hr vertical movement and 15rpm - 12rpm rotation. Bi2Sr2CaCu2O8 fibers have been grown with 300W halogen lamps and characterized with XRD, SEM and EDS. The growth condition was air atmosphere, growth speed 3∼4mm/hr, rotation speed of upper and lower part 20∼25 rpm. The fiber was composed of 20∼25 rpm matrix phase and secondary phases such as (Sr,Ca)CuO2 and (Sr,Ca)2CuO3.

  • PDF

Combustion Characteristics Study using Hyper-mixer in Low-enthalpy Supersonic Flow (하이퍼 혼합기를 사용한 저엔탈피 초음속 유동장 내연소 특성 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.75-80
    • /
    • 2013
  • In this study, a forced ignition method with a plasma jet torch is studied in Mach 2 laboratory scaled wind-tunnel. The hyper-mixer is used as a mixer. For two normal injection cases, the one is collided against a wedge plate of the hyper-mixer and the other is directly injected into the cold main flow. For the first case, the hyper-mixer disperses the injected fuel, leading to the mixing enhancement. Furthermore, the fuel-air mixture is provided into the plasma hot gas, which enhances the combustion performance. However, the direct injection into the main flow method spends amount of fuel without ignition in the cold supersonic flow. In the end, for the forced combustion, it is important to supply the fuel-air mixture into the heat source.

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF