Investigation on the Design Method of a Energy Harvesting Power Supply for a Smart Sensor (스마트 센서의 에너지 하베스팅 전원 공급부 설계 방안 연구)

  • Ho-Deok Jang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • A smart sensor is the key element to implement IoT (Internet of Things) service, as a terminal equipment. This paper investigated the design method of a power supply using energy harvesting technique for a smart sensor. the performance of a power supply using a solar cell and a piezoelectric transducer as a energy harvesting device was verified and the method to optimize a power supply was analyzed depending on the operating condition of a smart sensor. Also the method to increase a battery life cycle as a auxiliary power supply was proposed.

Implementation of Power Distribute Unit (PDU) combined with Uninterruptible Power Supply (UPS) for DC Server System (DC 서버를 위한 무정전 전원 공급장치 결합형 전원분배장치 구현)

  • Kwon, Won-Ok;Kim, Hag-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.236-238
    • /
    • 2012
  • 본 논문은 저전력 데이터센터에 사용되는 DC 서버를 위한 고효율 DC UPS 결합형 전원분배장치의 구현과 설계에 관한 내용이다. 본 논문이 제안한 노드 준위 UPS 결합형 전원분배장치의 전력효율은 96%에 이르며 저전력 볼륨 서버의 전원공급장치(PSU)와 UPS를 대체할 수 있는 기술이다.

Analysis of the Momentary Interruption Impact on the HANARO Operation (순간정전이 하나로 운전에 미치는 영향 분석)

  • Kim, Hyeong-Gyu;Jeong, Hwan-Seong;Choe, Yeong-San;U, Jong-Seop
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.655-656
    • /
    • 2004
  • 1) 제어봉의 전자 클러치는 직류전원 공급 장치에 의해 12V의 직류 전력을 공급받으며 전압 강하에 대한 내성이 좋다. 제어봉은 10V의 전압이 525msec 이상 지속될 때 전자력 상실로 낙하한다. 완전정전(0V)이 발생하여도 직류전원 공급 장치는 500msec 동안 전자클러치에 직류전력을 공급하여 제어봉의 연결 상태를 유지하도록 한다. 2) 정지봉 계통에 대한 전압강하의 영향은 제어회로를 구성하는 전자접촉기의 개방에 의하여 펌프의 전원공급이 차단되고, 그 결과 정지봉이 낙하한다. 정지봉은 펌프의 전원이 상실되면 수압 실린더의 압력 상실로 약 1000msec 후에 낙하한기 시작한다. 그림 2는 제어봉 및 정지봉에 대한 정전 영향을 시간에 따라 표시한 것이다. 3) 1차 및 2차 냉각계통의 부족전압 계전기에 의해 펌프가 정지할 때까지 저유량 신호 및 N/T mismatch 신호에 의한 원자로 정지신호는 발생되지 않는다. 따라서 정지봉 및 제어봉 계통에 적용하고자 하는 순간정전 보상장치는 부족전압 계전기 동작시간 이내의 보상시간에서만 가능할 것이다.

  • PDF

Power-Supply Time Control Device in Off-Peak Period for Thermal Storage Boiler (축열식 전기보일러의 심야전력 공급시간 자동제어장치)

  • Han, Seung-Ho;Kwon, Seong-Chul;Ko, Hi-Jung;Jeong, Woo-Yong;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2347-2349
    • /
    • 2002
  • 전기히터를 사용하는 축열기기의 보급이 급속히 활성화되고 모든 축열기기들이 심야전력 공급이 시작되는 22:00시에 동시에 가동이 시작되므로 심야전력 공급시작시간대에 전력수요피크가 발생하였다. 본 연구는 이러한 심야전력 공급시작시간을 상대적 저부하 시간대로 이동하기 위하여 대표적인 축열기기인 축열식 전기보일러의 적용할 심야전력 공급시간 자동제어장치 개발에 관한 것이다. 본 논문의 내용은 축열식 전기보일러의 축열조 잔열량에 따라 축열시작시간을 결정하는 자동제어장치의 알고리즘과 H/W, 그리고 시험실에서의 테스트와 현장에서의 검증작업을 포함한다.

  • PDF

Development of combustion test device for study of aluminum powder combustion (알루미늄 분말 연소시험을 위한 장치 개발)

  • Hwang, Yong-Seok;Lee, Ji-Hyung;Lee, Kyung-Hun;Kim, Kwang-Yun;Lee, Sung-Woong;Yeo, Tae-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.548-553
    • /
    • 2011
  • The device for studying combustion characteristic of aluminum powder and water was developed. The device has ability to adjust temperature, pressure, and equivalent ratio to some specified value which effect on combustion characteristic of aluminum and water mixture. Methane combustor, water supply device, aluminum powder feeder, and linear combustor are assembled to aluminum combustion test device. Each device has the ability to supply matter to combustor on steady and quantitatively controlled manner and test sequence specified by user can be automatically controlled. The combustion of aluminum powder was observed when integrated device was operated normally.

  • PDF

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

법령과 고시-도시가스사업법시행규칙 개정

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.1 s.198
    • /
    • pp.49-64
    • /
    • 2007
  • 도시가스사업법 시행규칙이 일부 개정되어 지난 해 12월 4일 공포되었다. 도시가스 배관 중 수요자에게 공급하기 위한 저압의 인입관(引入管) 공사 및 단순연결 공사 등 짧은 구간의 배관공사는 상주시공감리에서 제외하여 신속한 가스공급이 이루어지도록 하는 한편, 상주시공감리는 전공정(全公定)시공감리로, 일반시공감리는 일부공정시공감리로 용어를 정비하여 그 의미를 명확히 하고, 가스사용자의 토지 안에 공급관의 가스차단장치를 설치할 수 있도록 하되, 그 가스차단장치의 설치 및 유지관리 비용은 공급자의 부담으로 하는 등 현행 제도의 운영상 나타난 일부 미비점을 개선·보완하려는 것이다.

  • PDF

Electric current pulse supply unit use pulse power technique (펄스파워 기술을 이용한 전류펄스 공급장치)

  • Park, Sang-Gug
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.791-793
    • /
    • 2012
  • This paper describes development of the electric current pulse supply unit. This system is used to improve the problems of non-uniformed solidification structure, which is made in melting process of light weight alloy. The power supply switch of our system use MOSFET switch and gate control use PWM signal. We have simulated the designed circuit and made to PCB for the current pulse supply unit. The power circuits are simulated by a PSIM software. In the experiments, we have confirmed that the experiment results are follow the simulation results very well.

  • PDF

저궤도 위성 전원선 확인 시험

  • Yun, Yeong-Su;Won, Yeong-Jin;Kim, Jin-Hui
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.185.2-185.2
    • /
    • 2012
  • 저궤도 위성 비행모델 기능시험은 위성체 내부 전장품들 간의 접속 확인과 조립 및 연결상태를 확인하는 시험을 우선적으로 수행한다. 위성체의 전원선 확인 시험은 전기 전자적 조립 시험에서 가장 처음으로 수행하는 시험이다. 전력조절분배장치로부터 전장품 각각의 하드웨어로 공급되는 50볼트 주전원 또는 28볼트 부전원이 정상적으로 공급하게 되는지를 검증한다. 위성체 하니스가 설치된 후, 각각의 하드웨어에 공급되는 전원의 극성 및 연속성 시험을 수행한다. 전력조절분배장치는 태양전지판으로부터 얻어진 전력이 레귤레이터에 의해 정류된 전압을 받아 릴레이나 FET를 통하여 모든 전장품에 전원을 공급하는 주요 장비이다. 전력조절분배장치 내부나 외부 하니스 오류로부터 생길 수 있는 잘못 리드된 전원으로부터 전장품을 보호하기 위하여 하니스를 하드웨어에 연결하기 전에 우선적으로 전원선 확인 시험을 수행한다. 위성체 전원선 확인 시험은 위성체와 기능시험장비를 연결하여 시리얼 명령어를 통해 전력조절분배장치 내부의 FET 동작을 조절하며, FET 동작 상태 및 전장품에 접속되는 입력 단에서의 전압 및 전원 특성 등을 점검한다. 위성체의 주전원 50볼트 라인의 연결도 확인과 부전원 28볼트 라인의 연결도 확인 및 전력제어 유닛 내부 FET의 기능 확인을 수행하며 또한, 전력제어부 외부에 공급하는 28볼트 펄스와 15볼트 펄스를 측정 검증하는 시험을 수행한다.

  • PDF

Design and Analysis of Test Facility for the Experiment of Transpiration Cooling in Hot-flow Condition (고온유동 조건의 분출냉각 실험을 위한 시험장치의 설계 및 해석)

  • Lee, Jungmin;Na, Jaejeong;Kang, Kyoungtaik;Kwon, Minchan;Hwang, Kiyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.46-56
    • /
    • 2013
  • The test facility with hot-air supply system is required to develop transpiration cooling materials and experimentally evaluate its performance. In the study, the facility consists of an arc-plasma generator, plenum chamber suppling cold air, and test section was designed and an internal flow analysis was executed. From CFD results, it was confirmed that the designed plenum chamber thermally safeties and ideally mixes with plasma gas and cold air in the chamber. In addition, validity of design for supplying homogeneous flow to the test section was confirmed by this analysis.