A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel (난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

Forecasting of Heat Demand in Winter Using Linear Regresson Models for Korea District Heating Corporation (한국지역난방공사의 겨울철 열수요 예측을 위한 선형회귀모형 개발)

  • Baek, Jong-Kwan;Han, Jung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1488-1494
    • /
    • 2011
  • In this paper, we propose an algorithm using linear regression model that forecasts the demand of heated water in winter. To supply heated water to apartments, stores and office buildings, Korea District Heating Corp.(KDHC) operates boilers including electric power generators. In order to operate facilities generating heated water economically, it is essential to forecast daily demand of heated water with accuracy. Analysis of history data of Kangnam Branch of KDHC in 2006 and 2007 reveals that heated water supply on previous day as well as temperature are the most important factors to forecast the daily demand of heated water. When calculated by the proposed regression model, mean absolute percentage error for the demand of heated water in winter of the year 2006 through 2009 does not exceed 3.87%.

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

고층 아파트의 최적 열공급 시스템

  • 민만기;최영돈
    • Journal of the KSME
    • /
    • v.32 no.3
    • /
    • pp.247-254
    • /
    • 1992
  • 이 글에서는 고충아파트에서 층간 열공급의 불균일성이 발생하는 원인을 설명하였고 이 불균일 성을 해소시키는 새로운 열공급 설비 기술을 설명하였으며 그 내용들에 대한 결론은 다음과 같다. (1) 온수 난방 고층아파트의 층간 열공급의 불균일성은 온수공급관과 회수관의 정수압력의 차 이에 의한 유동저항에 의해서 발생한다. (2) 다구역배관망 시스템은 온수공급관과 회수관의 정수압력의 차이에 의해 발생하는 열공급 불균일성의 해소에 거의 기여하지 못한다. (3) 연속난방방식에서 서모스타트의 설치는 각세대의 열공급을 균일하게 할 수 있고 에너지 절 약면에서 가장 유리한 방식이나 고장의 위험성이 가장 크며, 운전의 미숙에 의한 열공급 제어의 불균일성을 초래하기 쉬우며 외기온도가 매우 낮으면 층간 열공급제어가 되지 않을 수 있어서 자동유량조절밸브를 병용하거나 온수공급압력을 충분히 크게 할 필요가 있다. (4) 자동유량조절밸브에 부착하면 단구역 배관망 시스템에서도 층간의 유량공급의 불균일성을 없앨 수 있으나 순환 펌프유량이 부족하면 밸브의 자동유량조절 기능이 상실된다. (5) 수동유량조절밸브는 TAB에 의해서 충간의 유량을 균일하게 조절할 수 있으나 펌프 성능변화 관부식 등이 발생하면 TAB를 다시 할 필요가 발생할 수 있다. 그러나 밸브의 고장이 적고 유 동저항을 적게 발생시키며 한 개의 밸브로 조절할 수 있는 유량의 범위가 큰 점에서는 가장 유 리하다.

  • PDF

Development of a New Water Circulating System for Hot Water Mattress Without Water Pump (새로운 펌프 없는 온수매트용 온수 순환 시스템의 개발)

  • Je, Jong Joo;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1031-1036
    • /
    • 2013
  • The motor-driven water pump boiler for a water circulating mattress generates noise and vibration as it supplies a large water flow rate. A non-pump boiler can reduce such noise and vibration, however, the water circulation flow rate becomes lesser than that in motor-driven water pump boilers, and a large temperature deviation occurs between the inlet and the outlet of the mattress. In this research, a new non-pump boiler for water circulating mattress is developed and its performance is experimentally validated and compared with the existing non-pump boilers. The experimental results show that temperature response time is improved and temperature deviation is reduced.

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

A Controller Development of Water Heating in a Ceramic Pipe Using Electronics Control System (전자제어 장치를 이용한 세라믹 파이프의 온수제어기 개발)

  • Lee, Jung-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.717-722
    • /
    • 2011
  • This paper presents that the electronic controller is developed for controlling the setting temperature and water in the ceramic pipe system. The heating water system is designed for controlling the temperature to supply the heat through the ceramic pipe heater to input the water, also for controlling quantity of water using the water sensor and impeller. The control method of the heating water system is applied the mathematic modeling of the ceramic pipe heater on the suppling the heat at coming water, and the test result of the electronic controller is present to smartly control the setting temperature, therefore the ceramic pipe heater is proposed to be able to apply the heating structure and the control methods as a product.

The Effects of Hot Water Supply Temperature on Indoor Thermal Characteristics for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수온도가 실내 열환경에 미치는 영향)

  • Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.13-19
    • /
    • 2018
  • The Effects of hot water supply temperature on indoor thermal characteristics for floor radiant heating system in residential apartment were researched by computer simulation. The parametric study on hot water supply temperatures with different outdoor air temperatures was done with regard to energy performance and control characteristics, respectively. As a result, the maximum overshoot of indoor air temperature and energy consumption were reduced by adjusting the hot water supply temperatures with outdoor air temperatures.

A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System (멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Yong-Yee;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.77-85
    • /
    • 2007
  • One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

Heat Transfer Analysis of a Coil-Typed LPG Vaporizer with an Electrically Heating Water Bath (전열온수식 LPG 기화기의 열전달 해석)

  • Choi, Sung-Joon;Kwon, Jeong-Rock;Kim, Kwang-Seok;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.19-25
    • /
    • 2007
  • The heat transfer phenomena in a coil-typed LPG vaporizer with a hot water bath employed an electrical heating system were experimentally analyzed. The heat energy is initially used to sensible heat region to heat LPG and then is done to latent heat region to vaporize LPG and to heat up the vaporized gas. A two-phase flow region could be found from periodic temperature fluctuations, and only sensible heat effect was found after passing through the region. The overall heat capacity was defined as multiplying the overall heat transfer coefficient by the heat transfer area and we found a correlation employing the heating water temperature and LPG flow rate. The results of this work can effectively be applied for the design of field scale LPG vaporizers in the near future because they can predict the features of heat transfer on a kind of coil type LPG vaporizer.

  • PDF