• 제목/요약/키워드: 공극비

검색결과 793건 처리시간 0.028초

A Study on the Effects of the Coefficient of Uniformity and Porosity on the Soil-Water Characteristic Curves of Sandy Soils (사질토의 함수특성곡선에 대한 균등계수와 공극율의 영향에 관한 연구)

  • Yoo, Kunsun
    • Journal of the Korean GEO-environmental Society
    • /
    • 제14권5호
    • /
    • pp.41-47
    • /
    • 2013
  • Well-graded and dense soils have good engineering properties. Unsaturated soil properties such as shear strength, compressibility and permeability are closely related to the soil-water characteristic curve of the soil. Therefore it is important to study the effects of the coefficient of uniformity and the porosity on the soil-water characteristic curve of the sandy soils, which are also related to the grain size distribution and the density of the soil, respectively. In this study soil-water characteristic curves (SWCCs) for six sandy soil specimens were investigated using Tempe pressure cells. The test data were best-fitted to Fredlund and Xing equation. The obtained fitting parameters and the characteristic points of SWCCs were discussed and correlated with the porosity and the coefficient of uniformity of the specimens. The results show that the smaller the porosity of the specimen becomes, the larger the value of the residual matric suction becomes, whereas the larger the coefficient of uniformity of the specimen becomes, the larger the value of the residual matric suction becomes. Regardless of the coefficient of uniformity, the smaller the porosity of the specimen, the flatter the max. slope of SWCC.

A Study on the Comparative Evaluation of wearing Fitness of Women′s Ready-made Jackets Using 3D Scanner (3D Scanner를 이용한 여성용 기성복 재킷의 착의적합성에 관한 비교평가연구)

  • Kim, Haekyung;Eunyoung Suk;Park, Soonjee;Chuyeon Suh;Jiyoung Lim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제25권10호
    • /
    • pp.1707-1718
    • /
    • 2001
  • 본 연구 목적은 3차원 인체 스캐너를 이용하여 여자 기성복 재킷의 여유량을 비교, 분석하는 것으로, 2사이즈 7브랜드의 재킷의 공극량을 계측하여 분석하였다. 첫째, 재킷 단면둘레 분석 결과, B85(품), B8(허리)를 제외하고 브랜드간에 유의한 차이를 나타내지 않아, 전반적으로, 브랜드간 제품치수에는 차이가 없는 것으로 나타났다. 둘째, 인체와 재킷의 단면둘레 분석 결과, 재킷의 배둘레를 제외한 모든 항목에서 유의한 차이가 나타나 피험자, 재킷 모두 사이즈에 따라 유의적인 차이 가 있음을 알 수 있다. 셋째, 기본사이즈 B85에서는 허리를 제외하고는 패턴 F가 가장 여유량이 많은 것으로 나타났으나, B88의 경우, 부위별로 각기 다른 패턴에서 여유량이 가장 많은 것으로 나타나, 각 부분마다 브랜드별로 그레이딩 룰이 다름을 알 수 있다. 넷째, 착의 단면은 인체와 의복간의 여유량 분포를 명백히 보여주며, 어깨, 가슴, 엉덩이처럼 몸에 밀착되는 부위는 다른 부위에 비해 패턴간, 각도별 변이가 적은 것으로 나타났다. 품, 허리, 배에서는 옆보다는 앞, 뒤로, 가슴에서는 앞뒤 좌우의 30$^{\circ}$방향, 엉덩이의 경우, 옆, 뒤보다는 앞쪽에 여유량이 집중되어 있는 것으로 나타났다. 다섯째, 브랜드별 평균공극길이에 대한 분산분석 결과, 전반적으로 패턴 F가 가장 공극량이 많고, 패턴 D가 작은 것으로 나타났다. 여섯째, 사이즈별 평균공극길이에 대한 t-검정 결과, 품과 배 부분에서, B88이 B85보다 공극량이 적은 것으로 나타나, 기준부위인 가슴, 허리, 엉덩이 부분뿐만 아니라 품, 배둘레의 치수에 대응할 수 있도록 그레이딩 룰 값을 산정하여야 함을 알 수 있다.

  • PDF

An Analysis of Pore Network of Drilling Core from Pohang Basin for Geological Storage of CO2 (이산화탄소 지중저장을 위한 포항분지 시추코어의 공극구조 분석)

  • Park, Jihwan;Park, Hyeong-Dong
    • Tunnel and Underground Space
    • /
    • 제26권3호
    • /
    • pp.181-191
    • /
    • 2016
  • In geological storage of $CO_2$, the behavior of $CO_2$ is influenced by pore network of rock. In this study, the drilling cores from Pohang Basin were analyzed quantitatively using three-dimensional images acquired by X-ray micro computed tomography. The porosities of sandstone specimens around 740 m-depth (T1), 780 m-depth (T2) and 810 m-depth (T3) which were target strata were 25.22%, 23.97%, 6.28%, respectively. Equivalent diameter, volume, area, local thickness of pores inside the sandstone specimens were analyzed. As a result, the microstructural properties of T1 and T2 specimens were more suitable for geological storage of $CO_2$ than those of T3 specimens. The result of the study can be used as input data of the site for decision of injection condition, flow simulation and so on.

A study on the variation of rock properties of weathered granites (화강암의 풍화현상에 수반되는 물성변화의 특성)

  • 김영화;장보안
    • The Journal of Engineering Geology
    • /
    • 제2권1호
    • /
    • pp.36-46
    • /
    • 1992
  • Granite core samples and bulk samples were first subjected to petrographic examination to determine weathering degrees. Secondly, their physical or mechanical properties including specific gravity, porosity, sonic wave velocity and uniaxial compressive strength were measured. The results were correlated to investigate the influences between properties including physical and mechanical properties, weathering degrees, and rock textures. Porosity and P wave velocity were found the most useful indices in determining the weathering degrees of granites.

  • PDF

핵연료내 결정립 외부 공극의 상호연결분률 예측용 정육각형 퍼콜레이션 모델

  • 김한철;이종인;조규성
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(2)
    • /
    • pp.500-505
    • /
    • 1996
  • 고온의 정상상태에서 조사된 후 재조직(restructuring)과 균열(cracking)이 일어난 핵연료 내에서 결정립 외부 공극의 을 결정할 수 있는 퍼콜레이션(Percolation) 모델을 개발하였다. 핵연료 펠렛은 다수의 작은 정육각형 결정립들로 구성된 큰 정육각형으로 모의한다. 핵연료봉은 형상과 열적 특성이 다른 네 개의 영역으로 구분하고 각 경계 위치를 임계온도로부터 계산한다. 공극의 상호연결분율은, 몬테카를로 방법으로써 싸이트(Site)의 채워짐 여부를 점검하고 Hoshen-Kopelman 방법으로써 자유 공간에 연결된 클러스터(Cluster)에 포함된 싸이트들의 수를 계산하여 채워진 싸이트의 총 개수에 대한 연결 싸이트들의 개수의 비로써 구한다. AECL-2230, CBX 핵연료봉 실험의 기체 방출분율 자료에 대하여, FASTGRASS 코드의 상호연결분율 함수를 영역별로 계산한 상호연결분율로 대치하여 계산한 결과와 비교하였다. 균열과 재조직은 핵분열 기체 방출에 상당히 영향을 미치는 것으로 나타났다. 이 모델의 주요 장점은 결정립계에서의 상호연결현상을 단순 상호연결분율보다 좀더 사실적으로 모의하며 결정립의 성장과 균열을 고려할 수 있다는 점이다.

  • PDF

Application of Electrical Resistivity Tomography to Analyze Soil Properties in Unsaturated Bone (불포화대 토양 특성 분석을 위한 전기비저항 토모그래피의 적용성)

  • Yong Hwan-Ho;Song Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • 제7권3호
    • /
    • pp.184-190
    • /
    • 2004
  • To analyze soil properties of unsaturated zone, we applied electrical resistivity tomography(ERT) of high resolution image. From linear relationship with each soil texture between results of ERT and soil properties such as electrical conductivity of pore water, water contents and ionic contents, we could be analyzed the result of ERT more effectively. Consequently, ERT can be useful for estimating soil properties between the two holes and evaluating indirectly pH and organic contents of soil.

Changes in the Constituents of Citrus Juice by Ultrafiltration (한외여과에 의한 온주 밀감주스의 성분 변화)

  • 김성미;강영주
    • Food Science and Preservation
    • /
    • 제8권4호
    • /
    • pp.442-448
    • /
    • 2001
  • The citrus juice obtained from Jeju mandarines, Citru unshiu, was filtered to remove 20% of its original volume through the hollow fiber ultrafiltration systems equipped with various pore sizes of membranes. As the results of ultrafiltration, the contents of total acids, ascorbic acid, ascorbic acid, free sugars and neohesperidin in retentate showed the tendencies of gradual decreases with the increase of membrane pore sizes from 10K to 100K daltons, but tendencies were inverted when the membrane with 500k was used. The changes of color, soluble solids, total nitrogen, amino-nitrogen, naringin and hesperidin were not consistent with the membrane pore size. Considering all the data obtained using various pen sizes of membranes, the filtration system with NMWC 500K daltons was the most effective to produce citrus juices with hither quality.

  • PDF

Effect of Foaming Agent on the Continuous Voids in Lightweight Cellular Concrete (경량기포콘크리트의 연속공극 형성에 미치는 기포제의 영향)

  • 이승한
    • Journal of the Korea Concrete Institute
    • /
    • 제14권5호
    • /
    • pp.742-749
    • /
    • 2002
  • This study was performed to clarify the formation procedure of continuous voids in cellular concrete, and to examine the effect of a foaming agent on the manufacture of cellular concrete with continuous voids. By the experiments, it was determined that cellular concrete to be formed with continuous voids is influenced by temperature, viscosity and flowability of cement paste, and stability of air voids, and is formed in accordance with cohesion of air voids. It was also found that separate voids are formed at an added amount of air voids corresponding to 2 % or less of the amount of cement, whereas an antifoaming phenomenon occurs when the added amount of air voids exceeds 9 % of the amount of cement. In products with respective cement fineness of 3,000, 6,000, and 8,000㎠/g, a higher compressive strength was exhibited at a higher cement fineness. The continuous void ratio depending on a variation in fineness was 38 %, 52 %, and 22 % in those products, respectively. That is, a highest continuous void ratio was exhibited at a cement fineness of 6,000㎠/g. When the water-cement ratio was reduced from 45% to 25%, the compressive strength of the cellular concrete was increased from 15 kgf/㎠ to 20 kgf/㎠ Thus, the reduction in water-cement ratio was effective in achieving an increase in strength without any variation in the specific gravity of the cellular concrete.

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • 제15권1호
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.

Changes in Cement Hydrate Characteristics and Chloride Diffusivity in High Performance Concrete with Ages (재령에 따른 고성능 콘크리트의 수화 특성치와 염화물 확산성 변화)

  • Koh, Tae-Ho;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제23권6호
    • /
    • pp.9-17
    • /
    • 2019
  • Cement hydrates and the related characteristics change with ages, and the behaviors are much related with chloride diffusion. In this work, 30% replacement ratio with FA(Fly Ash) and GGBFS(Ground Granulated Blast Furnace Slag) are considered for concrete with three levels of W/B (Water to Binder ratio) and 2 years of curing period. Chloride diffusion coefficients from accelerated condition are obtained at 5 measurement period (28days, 56days, 180days, 365days, and 730days), and the results are compared with porosity, binding capacity, and permeability from program-DUCOM. The similar changing pattern between chloride diffusion and permeability is observed since permeability is proportional to the square of porosity. Curing period is grouped into 4 periods and the changing ratios are investigated. Cement hydrate characteristics such as porosity, permeability, and diffusion coefficient are dominantly changed at the early ages (28~56 days), and diffusion coefficient in OPC concrete with low W/B continuously changes to 180days.