• Title/Summary/Keyword: 공간변조

Search Result 339, Processing Time 0.033 seconds

Design of a New 3-D 16-ary Signal Constellation with Constant Envelope (상진폭 특성을 가지는 새로운 3차원 16진 신호성상도의 설계)

  • Choe, Chae-Cheol;Kang, Seog-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2149-2156
    • /
    • 2011
  • In this paper, design of a new 3-dimensional (3-D) 16-ary signal constellation with constant envelope is presented and analyzed. Unlike the conventional 16-ary constellations, all signal points of the new constellation are uniformly located on the surface of a sphere so that they have a unique amplitude level and a symmetrical structure. When average power of the constellations is normalized, the presented 16-ary constellation has around 11.4% increased minimum Euclidean distance (MED) as compared to the conventional ones that have non-constant envelope. As a result, a digital communication system which exploits the presented constellation has 1.2dB improved symbol error rate (SER). While signal points of the conventional constant-envelope constellation are not distributed uniformly on the surface of a sphere, those of the proposed constellation has a completely symmetric distribution. In addition, the new signal constellation has much lower computational complexity for practical implementation than the conventional one. Hence, the proposed 3-D 16-ary signal constellation is appropriate for the application to a communication system which strongly requires a constant-envelope characteristic.

Dependence of Extinction Ratio on the Carrier Transport in $1.55{\mu}m$ InGaAsP/InGaAsP Multiple-Quantum-Well Electroabsorption Modulators ($1.55{\mu}m$ InGaAsP/InGaAsP 다중양자우물구조 전계흡수형 광변조기에서 캐리어 수송현상이 소광특성에 미치는 영향)

  • Shim, Jong-In;Eo, Yung-Seon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.9
    • /
    • pp.15-22
    • /
    • 2000
  • The effects of carrier transport and input power on the extinction ratio was theoretically analyzed in a 1.55${\mu}m$ InGaAsP/InGaAsP multiple-quantum-well(MQW) electroabsorption(EA) modulator. Poisson's equation, current continuity equations for electrons and holes, and optical field distribution were self-consistently solved by considering electric field dependent absorption coefficients. The field screening effect due to the carrier accumulation in heterointerface and the space-charge region occurred more seriously at the input side of modulator as input optical intensity increased. It was revealed that extinction ratio could be steeply degraded for modulator with the length of 200${\mu}m$ when an input power exceeds 10mW. A degradation of extinction ratio due to the field screening effect would be more significantly at high-performance devices such as a 1.55${\mu}m$DFB-LD/EA-modulator integrated source where optical coupling efficiency is almost complete or a very high-speed modulator with its length as short as a few tens ${\mu}m$.

  • PDF

Design and Implementation K-Band EWRG Transceiver for High-Resolution Rainfall Observation (고해상도 강수 관측을 위한 K-대역 전파강수계 송수신기 설계 및 구현)

  • Choi, Jeong-Ho;Lim, Sang-Hun;Park, Hyeong-Sam;Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.646-654
    • /
    • 2020
  • This paper is to develop an electromagnetic wave-based sensor that can measure the spatial distribution of precipitation, and to a electromagnetic wave rain gauge (hereinafter, "EWRG") capable of simultaneously measuring rainfall, snowfall, and wind field, which are the core of heavy rain observation. Through this study, the LFM transmission and reception signals were theoretically analyzed. In addition, In order to develop a radar transceiver, LFM transceiver design and simulation were conducted. In this paper, we developed a K-BAND pulse-driven 6W SSPA(Solid State Power Amplifiers) transceiver using a small HMIC(Hybrid Microwave Integrated Circuit). It has more than 6W of output power and less than 5dB of receiving NF(Noise Figure) with short duty of 1% in high temperature environment of 65 degrees. The manufactured module emits LFM and Square Pulse waveform with the built-in waveform generator, and the receiver has more than 40dB of gain. The transceiver developed in this paper can be applied to the other small weather radar.

Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography (MDCT에서의 Convolution Kernel 종류에 따른 공간 영역 필터링의 영상 평가)

  • Lee, Hoo-Min;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.71-81
    • /
    • 2008
  • Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were $1.1{\sim}1.8\;HU$, air($-998{\sim}-1000\;HU$) and noise in the water($5.4{\sim}44.8\;HU$), air($3.6{\sim}31.4\;HU$). In the abdominal fat a CT attenuation coefficient($-2.2{\sim}0.8\;HU$) and noise($10.1{\sim}82.4\;HU$) was measured. In the abdominal was CT attenuation coefficient($53.3{\sim}54.3\;HU$) and noise($10.4{\sim}70.7\;HU$) in the muscle and in the liver parenchyma of CT attenuation coefficient($60.4{\sim}62.2\;HU$) and noise ($7.6{\sim}63.8\;HU$) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  • PDF

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

The evaluation of usefulness of Electronic Portal Imaging Device(EPID) (Electronic Portal Imaging Device(EPID)의 유용성 평가)

  • Lee, Yang-Hoon;Kim, Bo-Kyoum;Jung, Chi-Hoon;Lee, Je-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2005
  • Purpose : To supply the information of EPID system and to analyze the possibility of substitution EPID for film dosimetry. Materials & Methods : With amorphous silicon(aSi) type EPID and liquid filled lonization chamber(LC) type EPID, the reproducibility according to focus detector distance(FDD) change and gantry rotation was analyzed, and also the possible range of image acquisition was analyzed with Alderson Rando phantom. The resolution and the contrast of aSi type EPID image were analyzed through Las Vegas phantom and water phantom. DMLC image was analyzed with X-Omat V film and EPID to see wether it could be applied to the qualify assurance(QA) of IMRT. Results : The reproducibility of FDD position was within 1mm, but the reproducibility of gantry rotation was ${\pm}2,\;{\pm}3mm$ respectively. The resolution and the contrast of EPID image were affected by dose rate, image acquisition time, image acquisition method and frame number. According to the possible range of image acquisition of EPID, it is verified that the EPID is easier to use than film. There is no difference between X-Omat V film and EPID images for the QA of IMRT. Conclusion : Through various evaluation, we could obtain lots of useful information about the EPID. Because the EPID has digital data, also we found that the EPID is more useful than film dosimerty for the periodical Qualify Assurance of IMRT. Especially when it is difficult to do point dose measurement with diode or ionization chamber, the EPID could be very useful substitute. And we found that the diode and ionization chamber are difficult to evaluate the sliding window images of IMRT, but the EPID was more useful to do it.

  • PDF

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Studies on Deacidification of Citrus Fruit and Juice for Juice Products by Heating Treatment and Electrodialysis (열처리 및 전기투석에 의한 초기수확 밀감의 탈산에 관한 연구)

  • Ko Won-Joon;Yang Min-Ho;Kang Yeung-Joo
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.144-153
    • /
    • 2006
  • The effects on deacidification of citrus fruits produced at early harvesting season for juice products were examined by heating treatment of raw fruits and electrodialysis of juice. Weight and total acidities were decreased by heating treatment for 40 hr at $25^{\circ}C,\;30^{\circ}C,\;35^{\circ}C\;and\;40^{\circ}C$, but $^{\circ}Brix$ and pH increased Sugar to acid ratio also increased. Total acidities were decreased from 1.25 (Oct30, 2004), 1.24 (Nov.5, 2004), 0.99 (Nov.13, 2004) and 0.98% (Nov.19, 2004) to 0.48 (Oct30, 2004), 0.51 (Nov.05, 2004), 0.37 (Nov.13, 2004) and 0.42% (Nov.19, 2004) by electrodialysis for 100 min respectively, and $^{\circ}Brix$ also slightly decreased, but solid to acid ratio was increased as a result. However pH and color remained almost unchanged by electodialysis. Also, free sugar contents of citrus juice little were changed, but organic acid content were decreased fairly. Narirutin and hesperidin content among flavonoids were slightly decreased by electrodialysis, but they were not significantly different. $K^+,\;PO_4^{2-},\;SO_4^{2-}\;and\;Cl^-$ content were decreased by electrodialysis, and $K^+$ contents decreased by more than 80% However, $Na^+$ consent was increased by about 2 times. Total polyphenol contents and electron donating abilities were decreased a little by electrodialysis but nitrite scavenging abilities were little changed. By acceptability test citrus juice prepared by electrodialysis for 100 min was superior to original citrus juice.

Effects of Nodus Nelumbinis Rhizomatis Extracts on Sociopsychological Stress in Mice (연근(蓮根) 추출물이 생쥐의 사회.심리적 스트레스에 미치는 영향)

  • Kim, Su-Yeon;Kim, Eun-Jeong;Lee, Dong-Won;Won, Ho-Young
    • Journal of Oriental Neuropsychiatry
    • /
    • v.15 no.2
    • /
    • pp.149-158
    • /
    • 2004
  • 만성적이거나 반복적인 스트레스는 우울중이나 심신병 등의 발병 기전과 밀접한 관련이 있다. 전기적 자극(electric foot shock), 한랭 자극, 속박(immobilization), 투쟁(fighting), 에테르 노출 등과 같은 심한 스트레스 자극이 뇌 조직의 시상 및 시상하부, 편도체 등에서의 노르아드레날린(noradrenalin) 방출을 유의 하게 감소시키는 동시에 혈청 corticosterone을 증가시키는 것으로 알려져 있다. 한의학에서는 스트레스 인자에 대한 신체반응을 기(氣)의 변화로 인식하고 있고, 이러한 자극요인들은 신체에 대하여 병적 요인을 제공하여 제반 질환을 야기한다. 또한 질병 발생에 대한 근거로 정기(正氣)와 사기(邪氣)의 상호 관계 위주로 인식하는데, 내부의 기(氣)의 변조(變調)는 질병의 발생을 야기하는 기초가 된다. 실험에 사용된 연근(蓮根)은 연꽃과에 속한 수생초본인 연꽃의 뿌리부분으로 우(藕) 또는 우절(藕節)이라는 명칭으로 불리기도 한다. 성미(性味)는 감(甘) 삽(澁) 평(平) 무독(無毒)하고 폐(肺) 위(胃) 간경(肝經)으로 들어가며 수렴지혈(收斂止血) 화어(化瘀)의 효능이 있어 토혈(吐血) 객혈(喀血) 뇨혈(尿血) 편혈(便血) 등의 각종 출혈 증상에 사용되어져 왔다. 최근 연꽃의 부위별 추출물이 흰쥐의 지질 과산화 생성을 효과적으로 억제하는 것으로 보고되고 있어 연근(蓮根)에 대한 다양한 약리 효능의 검색이 필요할 것으로 생각되며 연꽃의 씨앗인 연자육(蓮子肉)이 양심안신(養心安神)의 효능이 있어 스트레스성 질환에 많이 응용되고 있는 것에 착안하여 본 연구를 착수하였다. 실험 동물은 ICR계 마우스를 이용하였으며, 사회 심리적 스트레스는 옆쪽 cage에서 다른 마우스의 신체에 가해지는 전기 충격을 하루 1시간 동안 지켜보게 하는 것으로 유발하였으며 이 상태에서 약물을 투여한 그룹을 실험군, 그렇지 않은 그룹을 대조군으로 하였다. 정상군은 아무런 자극 없이 하루 1시간 동안 일정 공간에 가두어 두는 것으로 하였다. 실험 결과 사회 심리적 스트레스를 받은 경우에 아무런 처치를 하지 않은 대조군에 비해 연근 추출물을 100mg/kg/day 용량으로 5 일간 투여한 실험군에서 혈청 중 corticosterone 함량이 유의하게 감소하였으므로 매우 효과적으로 스트레스를 해소하였음을 알 수 있다. 뇌세포 중에서 신경전달물질로 분비되는 노르아드레날린의 분비량은 전반적으로 증가되는 경향을 나타내었으나 유의성은 없었다. 신체적 또는 사회 심리적 스트레스가 간 조직 내 지질의 과산화를 유발하는 것으로 나타났으며 연근 추출물이 이 결과에는 영향을 주지 못하였다. 사회 심리적 스트레스로 인하여 간 조직 내 지질과산화 정도가 증가하였으므로 혈청 내 ALT 함량도 따라 증가할 것으로 추정되었으며 이에 대한 연근 추출물 경구 투여가 간 조직을 보호할 수 있는지를 확인하기 위해 분리한 혈청으로부터 ALT 함량을 측정한 결과 대조군에 비하여 유의한 감소를 나타내었다. 또한 연근 추출물이 혈청 내 지질 과산화물의 생성을 억제할 수 있다면 질병의 예방과 치료에 효과적일 것으로 추정할 수 있으므로 그 생성량을 측정하여 보았으나 대조군과의 차이가 나타나지 않았다. 이상의 결과들을 종합하여 보면 스트레스가 부하된 5일 동안 연근(蓮根) 추출물을 함께 투여한 결과 혈청 corticosterone 함량을 유의하게 감소시켰고 뇌 조직내 noradrenaline 함량을 증가시키는 경향을 나타내어 스트레스 해소에 도움이 될 수 있음을 시사하였다. 또한 혈청 내 ALT 함량을 유의하게 감소시켜 스트레스로 인해 발생하는 간 기능의 손상도 어느 정도 억제시키는 것을 확인할 수 있었는데 앞으로 연근(蓮根)의 이러한 작용에 대한 보다 자세한 연구들이 필요한 것으로 생각된다.

  • PDF