• Title/Summary/Keyword: 골 고정원

Search Result 88, Processing Time 0.03 seconds

A study on the change of alveolar crest height following orthodontic treatment (교정치료와 관련된 치조골 높이 변화에 대한 연구)

  • Kang, Kyung-Hwa;Lee, Kyung-Won;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.599-611
    • /
    • 2000
  • Alveolar crest is the section of interproximal alveolar bone which includes the free edge of the alveolar process. An increase of the normal forces within limits of tolerance leads to deposition of new bone. If forces are beyond the limits of tolerance, resorption of bone will result whether the force produces pressure or tension. This study was designed to evaluate changes of alveolar bone levels in mesial and distal surface of the left, right first molar, by using pre-treatment, post-treatment panorama films. Two hundreds sixteen subjects were divided into adolescent group of 104 subjects and adult group of 112 subjects, to which orthodontic treatment with a bicuspid extraction (adolescent group-50 subjects, adult group-50 subjects) or without a nonextraction (adolescent group-54 !subjects, adult group-62 subjects) was applied by fixed appliances. Pre- and post-treatment Panorama films were traced, and alveolar crest height was measured. Amounts of changes in alveolar crest height by treatment were calculated md compared in terms of side of tooth, extraction, age. The results were as follows ; 1. When pre-treatment alveolar crest bone levels were compared, levels of adult group were significantly lower than those of adolescent group. 2. Post-treatment alveolar crest bone levels were significantly lower than pre-treatment levels. 3. When changes of alveolar crest height were compared, between adolescent and adult group were not significantly. 4. When changes of alveolar crest height were compared, significantly larger changes were noticed in ex윤action than nonextraction cases. 5. When changes of alveolar crest height were compared, significantly larger changes were noticed in maxilla than mandible. 6. When mesio-distally compared, significantly larger changes were observed in the distal than mesial sides of adult group.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Three-dimensional finite element analysis for stress distribution on the diameter of orthodontic mini-implants and insertion angle to the bone surface (교정용 미니임플랜트의 직경 및 식립각도에 따른 응력 분포에 관한 3차원 유한요소 분석)

  • Byoun, Na-Young;Nam, Eun-Hye;Kim, Il-Kyu;Yoon, Young-Ah
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.178-187
    • /
    • 2006
  • The present study was performed to evaluate the stress distribution on the diameter of the mini-implant and insertion angle to the bone surface. To perform three dimensional finite element analysis, a hexadron of $15{\times}15{\times}20mm^3$ was used, with a 1.0 mm width of cortical bone. Mini-implants of 8 mm length and 1.2 mm, 1.6 mm, and 2.0 mm in diameter were inserted at $90^{\circ},\;75^{\circ},\;60^{\circ},\;45^{\circ},\;and\;30^{\circ}$ to the bone surface. Two hundred grams of horizontal force was applied to the center of the mini-implant head and stress distribution and its magnitude were analyzed by ANSYS, a three dimensional finite element analysis program. The findings of this study showed that maximum von Mises stresses in the mini-implant and cortical and cancellous bone were decreased as the diameter increased from 1.2 mm to 2.0 mm with no relation to the insertion angle. Analysis of the stress distribution in the cortical and cancellous bone showed that the stress was absorbed mostly in the cortical bone, and little was transmitted to the cancellous bone. The contact area increased according to the increased diameter and decreased insertion angle to the bone surface, but maximum von Mises stress in cortical bone was more significantly related with the contact point of the mini-implant into the cortical bone surface than the insertion angle to the bone surface. The above results suggest that the maintenance of the mini-implant is more closely related with the diameter and contact point of the mini-implant into the cortical bone surface rather than the insertion angle.

Three Dimensional Study of Miniscrew about Installation Area and Angle (미니스크류 식립 각도 및 부위에 대한 3차원적 연구)

  • Jo, Hee-Sang;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • Minimizing damage to anatomical structure is a prerequisite for skeletal anchorage system to install a miniscrew. This research has focused on evaluating the stability and safety of installation in the maxillary molar buccal area, in which most miniscrews are installed clinically and initial fixation is weak. CT (computerized tomography)images were taken for surveying the possibility of damaging to adjucent teeth in accordance with installation angle. If we install a mini-screw($1.2{\times}6.0mm$) in the maxillary molar buccal area, it would be located generally in the 5~8mm upper of CEJ and 3~5mm inner of the cortical bone surface. We has measured the space between roots And comparison has been made for gender and the space between roots in accordance with the 3 different angles of installation(30 degree, 40 degree, 60 degree) in 3 categories. Category 1 : between 1st molar and 2nd molar Category 2 : between 1st molar and 2nd premolar Category 3 : between 1st premolar and 2nd premolar The result are as follow; 1. The space for category 1 was significantly small. 2. For the installation angle, it was safer to install with steeper angle in category 1 and category 2, but not in category 3. According to these results, the installation a miniscrew in category 2, 3 is safer than in category 1. And it is safer to install with steeper angle in category 1 and category 2.

3-dimensional finite element analysis of maxillary molar distalization using R-jig with TADs (TADs와 R-jig를 이용한 상악 구치 원심 이동에 관한 3차원 유한요소 분석)

  • Tark, Myung-Hyun;Lee, Keunyoung;Cho, Jin-Woo;Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.265-277
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the differences of displacement pattern depending on type of sliding jig and application method during maxillary molar distalization with temporary anchorage devices (TADs). Materials and Methods: Maxilla with normal tooth size and arch shape was selected to create a 3-dimensional finite element model, which included the bracket, orthodontic main archwire, removable sliding jig (R-jig). The orthodontic mini-implant anchorage was set 8 mm superiorly from main archwire, buccally between the second premolar and first molar. The base experimental design was Condition 1, which was composed $0.019{\times}0.025$ inch stainless steel (SS) of wire size of R-jig, 200 gm force, un-tied state. And the other designs varied to wire size of R-jig, magnitude of force. The results are as follows. Results: As the wire size of R-jig was increased, the deformation of R-jig was decreased. However, the displacement of second molar wasn't different each other. As the force to second molar was increased, the more displacement of second molar was observed, and the more distal tipping movement, vetical displacement was observed. Conclusion: R-jig can get distal teeth movement in orthodontic treatment without side effects.

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture (골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

MAXILLARY MOLAR DISTALIZATION WITH A PENDULUM APPLIANCE (Pendulum 장치를 이용한 상악 대구치의 원심이동 증례)

  • Lee, H.J.;Kim, Y.J.;Kim, J.W.;Jang, K.T.;Lee, S.H.;Kim, C.C.;Hahn, S.H.
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.523-531
    • /
    • 2008
  • Maxillary molar distalization is a treatment approach for patients with Class II malocclusions who do not require extractions and mesial movements of mandibular molars. The pendulum appliance is effective for distalization of the maxillary molars and independent of patient cooperation. This appliance can stabilize the maxillary premolars and use the palatal rugae area as an additional anchorage. However, caution is needed to control collateral effects, including increase of lower facial height, incisor protrusion and damage to the rugae area. This article reports the cases in which maxillary molar distalization achieved by pendulum appliance resolves the space problems and corrects the molar relationships.

  • PDF

Rapid canine retraction in a Class II bialveolar protrusion case using a lingually extended distraction screw (제II급 치조 전돌 환자에서 설측 견인 장치를 이용한 급속 견치 견인술)

  • Ahn, Kwang-Seok;Joo, Euk;Park, Ju-Young;Ryu, Young-Kyu;Cha, In-Ho;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.308-320
    • /
    • 2006
  • Rapid canine retraction, first introduced by Liou, is a distraction osteogenesis applied to the periodontal ligament tissue. Rapid tooth movement was facilitated by establishing minimal bony resistance on the distal surface of the canine by socket preparation and by osteogenesis on the mesial side in response to the periodontal distraction. Since undesired buccal tipping or extrusion of the canine during retraction tends to occur, it is crucial to maintain the firm path of movement and the axis of the canine during retraction. In order to improve the predictability of the canine movement, lingually extended distraction screws with heavy labial guiding wires were designed. Prefabricated plastic canine models for the estimation of socket depth and miniscrew implants for anchorage reinforcement were also devised. Applying these devices to a female patient with Class II anterior protrusion, the whole treatment was effectively finished in 13 months. Loss of vitality or periodontal problems did not occur throughout treatment, and stable occlusion was maintained during 10 months of retention. This case report demonstrates that a predictable rapid canine retraction can be achieved through the use of this modified technique.

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

A Two Dimensional Stress Analysis of Fixed Prosthesis with Rigid or Nonrigid Connectors (비고정성 연결장치를 갖는 가공의치의 응력분석)

  • Yang H.S.;Thomposn V.P.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.445-456
    • /
    • 1992
  • A two dimensional finite element model was constructed to analyze the mechanical behavior of a five unit fred partial denture(FPD) with a 2nd premolar pier abutement either employing a rigid or nonrigid connector. Gap elements were used to model the clearance space of the nonrigid connector. All FPDs with rigid or nonrigid connectors reduced the magnitude of stress in the periodontium as compared to the control, with both normal or reduced bone support. An FPD with rigid connectors induced the smallst stresses in the periodontium. A FPD with a nonrigid connector on the mesial of the molar abutment exhibited the most undesirable mechanical stress states and deformations.

  • PDF