Choi Doo Ho;Kim Eun Seog;Kim Yong Ho;Kim Jin Hee;Yang Dae Sik;Kang Seung Hee;Wu Hong Gyun;Kim Il Han
Radiation Oncology Journal
/
v.23
no.2
/
pp.61-70
/
2005
Purpose: Uterine cervix cancer is one of the most prevalent women cancer in Korea. We analysed published papers in Korea with comparing Patterns of Care Study (PCS) articles of United States and Japan for the purpose of developing and processing Korean PCS. Materials and Methods: We searched PCS related foreign-produced papers in the PCS homepage (212 articles and abstracts) and from the Pub Med to find Structure and Process of the PCS. To compare their study with Korean papers, we used the internet site 'Korean Pub Med' to search 99 articles regarding uterine cervix cancer and radiation therapy. We analysed Korean paper by comparing them with selected PCS papers regarding Structure, Process and Outcome and compared their items between the period of before 1980's and 1990's. Results: Evaluable papers were 28 from United States, 10 from the Japan and 73 from the Korea which treated cervix PCS items. PCS papers for United States and Japan commonly stratified into $3\~4$ categories on the bases of the scales characteristics of the facilities, numbers of the patients, doctors, Researchers restricted eligible patients strictly. For the process of the study, they analysed factors regarding pretreatment staging in chronological order, treatment related factors, factors in addition to FIGO staging and treatment machine. Papers in United States dealt with racial characteristics, socioeconomic characteristics of the patients, tumor size (6), and bilaterality of parametrial or pelvic side wail invasion (5), whereas papers from Japan treated of the tumor markers. The common trend in the process of staging work-up was decreased use of lymphangiogram, barium enema and increased use of CT and MRI over the times. The recent subject from the Korean papers dealt with concurrent chemoradiotherapy (9 papers), treatment duration (4), tumor markers (B) and unconventional fractionation. Conclusion: By comparing papers among 3 nations, we collected items for Korean uterine cervix cancer PCS. By consensus meeting and close communication, survey items for cervix cancer PCS were developed to measure structure, process and outcome of the radiation treatment of the cervix cancer. Subsequent future research will focus on the use of brachytherapy and its impact on outcome including complications. These finding and future PCS studies will direct the development of educational programs aimed at correcting identified deficits in care.
Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
Radiation Oncology Journal
/
v.23
no.3
/
pp.186-193
/
2005
Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.
Chun Mison;Kang Seunghee;Jin Yoon-Mi;Oh Young-Taek;Kil Hoon-Jong;Oh Tae-Young;Ahn Byoung-Ok
Radiation Oncology Journal
/
v.19
no.3
/
pp.265-274
/
2001
Purpose : Proctitis is one of acute complications encountered when radiotherapy was appled to the pelvis. Radiation-induced proctitis represents similar microscopic findings that are observed in inflammatory bowel disease (IBD). Nitric oxide (NO) plays an important role in the inflammatory process and many data suggest a close relationship between NO production and gastrointestinal inflammation. This study was aimed to establish the optimal radiation dose for radiation-induced proctitis in rat and to find a relationship between radiation proctitis and NO production. Materials and methods : Female Wistar rats, weighing from 150 to 220 g, received various doses(10-30 Gy) of radiation to the rectum. On the 5th and 10th day after irradiation, rectal specimens were evaluated grossly and microscopically. In addition, the degree of NO production by irradiation dose was evaluated by study with NOS expression and nitrite production in the irradiated rectal tissue. To evaluate relationship between radiation proctitis and NO, we administered aminoguanidine, iNOS inhibitor and L-arginine, substrate of NOS to rats from 2 days before to 7 days after the irradiation. Results : There were obvious gross and hostological changes after 17.5 Gy or higher radiation dose but not with 15 Gy or less radiation dose. Twenty Gy or higher dose of radiation caused Grade 4 damage in most of rectal specimens which were more likely to be related to the late complications such as fibrosis, rectal bleeding and rectal obstruction. A single fraction of 17.5 Gy to the rat rectum is considered to be an optimal dose to produce commonly experienced proctitis in the clinic. The result demonstrated that severity of microscopic damage of rectal mucosa from irradiation significantly correlated with iNOS over-expression. However, administration of iNOS inhibitor or substrate of iNOS did not influence the degree of rectal damage. Conclusion : A single fraction of 17.5 Gy irradiation to the rat rectum considered to be an optimal dose for radiation induced proctitis model. These results indicated that an excess production of NO contributes to pathogenesis of radiation-induced proctitis in part but was not the direct cause of rectal damage.
Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.
The Journal of the Korean bone and joint tumor society
/
v.19
no.2
/
pp.56-63
/
2013
Purpose: This study was performed to evaluate the efficiency of demineralized bone matrix (DBM, Genesis$^{(R)}$) used for bone defect after operative traetment of benign bone tumors by clinical and radiological methods. Materials and Methods: DBM was used to treat bone defect after operative treatment of benign tumor from February 2012 to May 2013. Total 25 benign bone tumor cases (15 males, and 10 females) with mean age of 30.3 were studied. The diagnoses were solitary bone cyst in 9 cases, non ossifying fibroma in 5, fibrous dysplasia in 5, aneurysmal bone cyst in 3 and enchondroma in 3. In categorization by location of tumor, there were 5 cases of distal femur, 4 of proximal tibia, 3 of proximal femur, 3 of proximal humerus, 3 of phalanx, 2 of distal radius, 2 of hip bone, 2 of calcaneus, and 1 of scapula. Autogenous bone was used with DBM in 6 cases, and only DBM used in 19 cases. Mean periods of follow up were 8.7 months (range: 6 to 14 months). Amount of graft resorption and bone formation was observed with compare of post operation radiograph and the difference was shown by percentage. Resorption level was measured by DBM level which could be observed from simple x-ray, and bone formation level by bone trabecular formation level at impaired site. Results: Twenty three cases of total 25 cases showed bone union. In the 23 cases, more than 98% DBM resorption was observed after mean 4.3 months, and more than 98% bone formation was observed after mean 6.9 months. Lesser bone defect sizes showed faster bone formation and it was statistically significant (p=0.036). But other comparative studies on other factors such as, sex, age of patients and combination of autogenous bone were no statistically significant differences in graft resorption and bone formation. And there was no significant complication in periods of follow-up. Conclusion: Demineralized Bone Matrix (Genesis$^{(R)}$) is thought to be useful treatment for bone defect after operative treatment of benign bone tumor, however longer follow-up periods appears to be needed.
Purpose: To retrospectively assess the advantages and side effects of prophylactic Paraaortic irradiation in cervical cancer patients with common iliac nodal involvement, the results for survival, patterns of failure, and treatment-related toxicity. Materials and Methods: From May 1985 to October 2004, 909 patients with cervical carcinoma received postoperative radiotherapy at the Seoul National University Hospital. Among them, 54 patients with positive common iliac nodes on pathology and negative Paraaortic node were included in the study. In addition, 44 patients received standard pelvic irradiation delivered 50.4 Gy per 28 fractions (standard irradiation group), and chemotherapy was combined in 16 of them. The other 10 patients received pelvic irradiation at a dose of 50.4 Gy per 28 fractions in addition to Paraaortic irradiation at 45 Gy per 25 fractions (extended irradiation group). In addition, all of them received chemotherapy in combination with radiation. Follow-up times for pelvic and Paraaortic irradiation ranged from 6 to 201 months (median follow-up time, 58 months) and 21 to 58 months (median follow-up time, 47 months), respectively. Results: The 4-year overall survival, disease free survival, and distant metastasis free survival in the standard irradiation group and extended irradiation group were 67.2% vs. 90.0% (p=0.291), 59.0% vs. 70.0% (p=0.568) and 67.5% vs. 90.0% (p=0.196), respectively. The most common site of first failure for the standard irradiation group was the paraaortic lymph node, while no paraaortic failure was observed in the extended irradiation group. Relatively, hematologic toxicity grade 3 or greater was common in the extended irradiation group (2/10 extended vs. 2/44 standard), while gastrointestinal toxicity of grade 3 or greater was lower (2/10 extended vs. 6/44 standard), and urologic toxicity of grade 3 or greater was observed in the standard irradition group only (0/10 vs. 3/44). Conclusion: Concurrent chemotherapy and prophylactic Paraaortic irradiation in patients with common iliac nodal involvement showed slightly improved clinical outcomes aside from increased hematologic toxicity, which was statistically insignificant. Considering the relatively small number of patients and short follow-up times, additional studies are needed to obtain more conclusive outcomes.
The Journal of Korean Society for Radiation Therapy
/
v.29
no.1
/
pp.69-76
/
2017
Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.
Lee Woo-Suk;Park Seong-Ho;Yun In-Ha;Back Geum-Mun;Kim Jeong-Man;Kim Dae-Sup
The Journal of Korean Society for Radiation Therapy
/
v.17
no.2
/
pp.147-153
/
2005
Purpose : We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability.,Materials and Methods : Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department.,Results : About thickness at body measure point. we could find difference of $1{\sim}2$ cm relationship general measure and image measure. General measure and image measure of body length was seen difference of $3{\sim}4$ cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by $92{\sim}98%$ and abdomen, pelvis, inquinal region, feet region were measured by $102{\sim}109%$.,Conclusion : It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly. and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall $15\{sim}20$ minute time. and reduce compensator manufacture time about 15 minutes.
Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.
Youn Seon Min;Choi Tae Jin;Koo Eun Sil;Kim Ok Bae;Lee Seung Moon;Suh Soo Jhi
Radiation Oncology Journal
/
v.15
no.2
/
pp.145-151
/
1997
Purpose : To evaluate the loss of bone mineral contents(BMC) in lumbar spine within the radiation field for cervical cancer treatment, BMC in the irradiated patient group was compared with that of a normal control group. Method and materials : Measurements of BMC in the trabecular bone in lumbar spines(L3-L5) were performed in the both patient and normal control groups. Investigators used dual-energy quantitative computerized tomography(DEQCT) using Photon energy of 120 and 80kVp, The numbers of Patient and control groups were 43 in each with age distribution of fifth to seventh decade of women. The numbers of control group were 22 in fifth, 10 in sixth and 11 in seventh decade, those of patient group were 14 in filth, 14 in sixth, and 15 in seventh decade of women. The radiation field was extended to L5 spine for Pelvic irrdiation with 45-54Gy of external radiation dose and 30Gy of high dose rate brachytherapy in cervical cancer, Results : The BMC is decreased as increasing age in both control and patient groups. BMC in lumbar spine of patient group was decreased by about $13\%\;to\;40\%$ maximally. The BMC of L3 and L4 a region that is out of a radiation field for the Patient group demonstrated $119.5\pm30.6,\;117.0\pm31.7\;for\;fifth,\;83.3\pm37.8,\;88.3\pm46.8\;for\;sixth\;and\;61.5\pm18.3,\;56.2\pm26.6mg/cc$ for seventh, Contrasted by the normal control group has shown $148.0\pm19.9,\;153.2\pm23.2\;for\;fifth,\;96.1\pm30.2,\;105.6\pm26.5\;for\;sixth\;and\;73.9\pm27.9,\;77.2\pm27.2mg/cc$ for seventh decade, respectively The BMG of patient group was decreased as near the radiation field, while the lower lumbar spine has shown more large amounts of BMC in the normal control group. In Particular, the BMC of L5 within the radiation field was significantly decresed to $33\%,\;31\%,\;40\%$ compared with the control group of the fifth, sixth and seventh decades, respectively. Conclusion : The pelvic irradiation in cervical cancer has much effected on the loss of bone mineral content of lumbar spine within the radiation field, as the lower lumbar spine has shown a smaller BMC in Patient group with Pelvic irradiation in contrast to that of the normal control groups.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.