• Title/Summary/Keyword: 곡선 보

Search Result 1,554, Processing Time 0.04 seconds

Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss (소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용)

  • Lee, Mi-Young;Suh, Suk-Kwon;Lee, Choong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.539-553
    • /
    • 1996
  • The study was conducted from May to September in 1994 to investigate applicability of the Hearing Handicap Inventory for the Elderly-Screening version(HHIE-S) in parallel with the pure-tone audiometer to the initial screening test of noise-induced hearing loss(NIHL) in some noise-exposed workers. Subjects were selected by systemic sampling that took every 10th person from 6, 700 workers taking the annual occupational health examination by the department of Health Maintenance of Dongsan Hospital Keimyung University in Taegu. The authors administered the pure-tone audiometric test and self-reported questionnaire of HHIE-S including items of sociodemographic and job-related variables concurrently. The final subjects analysed were 1,019(488 males and 531 females) excluding fourteen persons who had many missing values in their questionnaires. The reliability coefficients of HHIE-S scale by Cronbach's alpha were 0.84. In the univariate analysis of hearing handicap measured by the HHIE-S, work duration, military service and the hearing threshold loss at 1KHz and 4KHz by the initial audiometer were significant in males while age, work duration and hearing threshold loss at 1KHz and 4KHz were significant in females. In the stepwise linear regression analysis, hearing threshold loss at 1KHz and 4KHz, was the only selected variable explaining the hearing handicap in males and hearing threshold loss at 1KHz and 4KHz, age, and work duration were selected in females. In ROC curves for HHIE-S scores against NIHL as gold standard which was defined by the follow-up audiogram as more than 30dB of the average of 0.5/1/2KHz and 50dB at 4KHz, the optimal cutoff for the parallel HHIE-S appeared to be 8. The results suggest that HHIE-S appeared to have some reliability and validity in this data and might be used in screening NIHL in parallel with pure-tone audiometer in noise-exposed workers.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm (선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석)

  • Kim, Dae-Sup;Yoon, In-Ha;Lee, Woo-Seok;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.137-147
    • /
    • 2012
  • Purpose: Analyze the Effectiveness of Radiation Treatment Planning by dose calculation and optimization algorithm, apply consideration of actual treatment planning, and then suggest the best way to treatment planning protocol. Materials and Methods: The treatment planning system use Eclipse 10.0. (Varian, USA). PBC (Pencil Beam Convolution) and AAA (Anisotropic Analytical Algorithm) Apply to Dose calculation, DVO (Dose Volume Optimizer 10.0.28) used for optimized algorithm of Intensity Modulated Radiation Therapy (IMRT), PRO II (Progressive Resolution Optimizer V 8.9.17) and PRO III (Progressive Resolution Optimizer V 10.0.28) used for optimized algorithm of VAMT. A phantom for experiment virtually created at treatment planning system, $30{\times}30{\times}30$ cm sized, homogeneous density (HU: 0) and heterogeneous density that inserted air assumed material (HU: -1,000). Apply to clinical treatment planning on the basis of general treatment planning feature analyzed with Phantom planning. Results: In homogeneous density phantom, PBC and AAA show 65.2% PDD (6 MV, 10 cm) both, In heterogeneous density phantom, also show similar PDD value before meet with low density material, but they show different dose curve in air territory, PDD 10 cm showed 75%, 73% each after penetrate phantom. 3D treatment plan in same MU, AAA treatment planning shows low dose at Lung included area. 2D POP treatment plan with 15 MV of cervical vertebral region include trachea and lung area, Conformity Index (ICRU 62) is 0.95 in PBC calculation and 0.93 in AAA. DVO DVH and Dose calculation DVH are showed equal value in IMRT treatment plan. But AAA calculation shows lack of dose compared with DVO result which is satisfactory condition. Optimizing VMAT treatment plans using PRO II obtained results were satisfactory, but lower density area showed lack of dose in dose calculations. PRO III, but optimizing the dose calculation results were similar with optimized the same conditions once more. Conclusion: In this study, do not judge the rightness of the dose calculation algorithm. However, analyzing the characteristics of the dose distribution represented by each algorithm, especially, a method for the optimal treatment plan can be presented when make a treatment plan. by considering optimized algorithm factors of the IMRT or VMAT that needs to optimization make a treatment plan.

  • PDF

Development of pSJE6c, an Expression Vector for Kimchi Lactic Acid Bacteria, and Heterologous Gene Expression Using the Vector (김치유산균용 발현벡터 pSJE6c 개발과 이를 이용한 외래 유전자 발현)

  • Lee, Kang-Wook;Park, Ji-Yeong;Lee, Ji-Yeon;Lee, Hwang-A;Baek, Chang-Un;Jo, Hyeon-Deok;Kim, Joo-Yeon;Kwon, Gun-Hee;Chun, Ji_Yeon;Kim, Jeong-Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.4
    • /
    • pp.389-398
    • /
    • 2009
  • Development of expression vectors is important for the basic and applied researches on kimchi LAB (lactic acid bacteria). An expression vector, pSJE6c was constructed by inserting P6C promoter sequence from Lactococcus lactis into pSJE, a shuttle vector for E. coli and Leuconostoc species. To test the efficiency of pSJE6c, aga ($\alpha$-galactosidase) and lacZ ($\beta$-galactosidase) genes were expressed in Lactobacillus brevis 2.14. Compared to the pSJE, expression levels of both genes were increased, indicating P6C promoter was better than indigenous promoters. Enzyme activities of L. brevis cells harboring pSJE6caga (pSJE6c with aga) or pSJE6Z (pSJE6c with lacZ) were 1.5-2 fold higher than those with pSJEaga (pSJE with aga) or pSJEZ (pSJE with lacZ). More RNA transcripts were detected in cells harboring pSJE6c based recombinant plasmid. The results indicated that heterologous gene expressions in kimchi LAB could be improved significantly by use of efficient expression vectors.

Biokinetics of Carbohydrate and Lipid Metabolism in Normal Laying Hen [Part 1] -Determination of Turnover of Glucose- (정상산란계(正常産卵鷄)에 있어서 탄수화물(炭水化物)과 지질대사(脂質代謝)의 생동역학(生動力學) 제1보[第一報] -포도당 대사회전(代謝回轉)의 측정(測定)-)

  • Chiang, Y.H.;Riis, P.M.
    • Applied Biological Chemistry
    • /
    • v.20 no.2
    • /
    • pp.205-209
    • /
    • 1977
  • The pool size of plasma glucose, turnover rate and other concerned items for glucose metabolism in normal laying hen were investigated by a single-injection method using $U-C^{14}-glucose$. The 11.6 nCi of pure dose was injected to a hen normally fed through the wing vein. The glucose concentration in plasma sample taken at 5 minutes after injections was 214mgper 100ml. From the plottings of logarithmic standard specific activities of plasma taken from 5 to 120 minutes against the time after injection and from the regresion analysis, metabolic states were determined. The pool size was 1.07g, turnover rate was 0.024 per minute, turnover time was 41 minutes, utilization rate was 26mg/min. (0.83 g/hr/kg B.W. 3/4) and glucose space(extracellular fluid volume) was 25.3 per cent of body weight. The values obtained from. 10-50 minutes samples were similar to those described above, which we from 5-120 minutes samples.

  • PDF

A Study on Developing Sensibility Model for Visual Display (시각 디스플레이에서의 감성 모형 개발 -움직임과 색을 중심으로-)

  • 임은영;조경자;한광희
    • Korean Journal of Cognitive Science
    • /
    • v.15 no.2
    • /
    • pp.1-15
    • /
    • 2004
  • The structure of sensibility from motion was developed for the purpose of understanding relationship between sensibilities and physical factors to apply it to dynamic visual display. Seventy adjectives were collected by assessing adequacy to express sensibilities from motion and reporting sensibilities recalled from dynamic displays with achromatic color. Various motion displays with a moving single dot were rated according to the degree of sensibility corresponding to each adjective, on the basis of the Semantic Differential (SD) method. The results of assessment were analyzed by means of the factor analysis to reduce 70 words into 19 fundamental sensibilities from motion. The Multidimensional Scaling (MDS) technique constructed the sensibility space in motion, in which 19 sensibilities were scattered with two dimensions, active-passive and bright-dark Motion types systemically varied in kinematic factors were placed on the two-dimensional space of motion sensibility, in order to analyze important variables affecting sensibility from motion. Patterns of placement indicate that speed and both of cycle and amplitude in trajectories tend to partially determine sensibility. Although color and motion affected sensibility according to the in dimensions, it seemed that combination of motion and color made each have dominant effect individually in a certain sensibility dimension, motion to active-passive and color to bright-dark.

  • PDF

Mitochondrial DNA Copy Number in the Patients of Korean Polycystic Ovary Syndrome (PCOS) (한국인 다낭성난소증후군 환자에서 미토콘드리아 DNA Copy 수의 정량적 분석)

  • Park, Ji-Eun;Jang, Min-Hee;Cho, Sung-Won;Kim, Yoo-Shin;Won, Hyung-Jae;Cho, Jung-Hyun;Baek, Kwang-Hyun;Lee, Sook-Hwan
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.33 no.4
    • /
    • pp.245-251
    • /
    • 2006
  • Objective: We analyzed quantification of mitochondria DNA (mtDNA) to investigate the relationship of mitochondria and pathogenesis of PCOS. Materials and Methods: Peripheral blood samples were collected from 28 patients with PCOS who were under the inclusion criteria for PCOS and from 28 healthy controls. Genomic DNA was used to analyze real-time PCR for mtDNA copy number quantification. The mtDNA copy number was compared between the control and PCOS groups. All data was expressed as mean ${\pm}$ SD. Statistical analysis was assessed by t-test. Results: In this study, the mtDNA $C_T$ was $11.67{\pm}0.422$ in PCOS patients and $11.51{\pm}0.722$ in control group, respectively. The mtDNA copy number was $1726410.71{\pm}407858.591$ the patients of in PCOS and $2167887.51{\pm}252459.28$ in control group (p=0.08), respectively. Conclusion: In our study, using real-time PCR, there was a tendency of lower mtDNA copy number in the patients of PCOS when comparing to the control group even though statistical difference was not significant. However, more extensive analysis is required to clarity relationship between mtDNA copy number and pathogenesis of PCOS.

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

Studies on Spat Production of the Sun and Moon Scallop, Amusium japonicum japonicum (GMELIN) (해가라비, Amusium japonicum japonicum (GMELIN) 종묘생산에 관한 연구)

  • Son, Pal-won;Ha, Dong-soo;Rho, Sum;Chang, Dae-soo;Lee, Chang-hoon;Kim, Dae-Kweon
    • Journal of Aquaculture
    • /
    • v.11 no.3
    • /
    • pp.371-380
    • /
    • 1998
  • This study has been conducted to develop the techniques for spat production of the sun and moon scallop from January 1995 to December 1996. With the adult scallops collected from the Sogwipo area, spawning induction and larvae rearing were attempted several times and monthly changes of GSI were also monitored during the experimental period. The results obtained wre as follows. 1. GSI started to increase from June and showed the maximum value of 22.17 and 14.98 in female and male respectively in November, and then gradually decreased from December. 2. Spawning induction by heating method turned out to the most efficient way showing the responding rate of 64.8~91.5%. The responding temperature was $21.4~26.4{\circ}C$ which was $3.1~8.5{\circ}C$ increased from the rearing temperature of $16.3~18.3{\circ}C$. An average number of eggs spawned was $9.2{\times}10^5$ 3. the average size of eggs after fertilization was about $72{\mu}m$ in diameter. The first polar body discharge, blastula formation, and trochopore larvae appearance occurred 30 mininutes, 18 hours, and 22 hours after fertilization respectively. 4. Settling rates in various collectors were similar one another, whereas pouring larvae in the mesh was the most efficient way for larval setting. 5. The spates grew to be 1mm in their shell length for the first 50 days after fertilization and 9.6mm in 135days. 6. Correlation between shell length (SL) of the spat and the number of days (X) after spat settlement could be expressed as $SL=257.75e ^{0.0272x}$(r=0.9100).

  • PDF

Analysis of Diagnostic Performance of CT and EUS for Clinical TN Staging of Gastric Cancer (위암의 임상적 병기 설정을 위한 전산화단층촬영 및 초음파 내시경의 진단력 평가)

  • Shin, Ru-Mi;Lee, Ju-Hee;Lee, Moon-Soo;Park, Do-Joong;Kim, Hyung-Ho;Yang, Han-Kwang;Lee, Kuhn-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.177-185
    • /
    • 2009
  • Purpose: Preoperative clinical staging of gastric cancer is very important for determining the treatment plans and predicting the prognosis. The previous reports regarding the accuracy of computed tomography or endoscopic ultrasound for the preoperative staging of gastric cancer have shown various outcomes. We analyzed the diagnostic performance of CT and EUS, which are important staging tools for the staging of TN gastric cancer. Materials and Methods: We retrospectively analyzed 1,174 patients who underwent gastrectomy for gastric cancer at Seoul National University Bundang Hostpital from May, 2003 to December, 2007. We derived the Kappa value to examine the agreement of the preoperative staging obtained from CT and EUS with the pathological staging. Results: The mean age of the 1,174 patients was $59.31{\pm}11.98$ years. Six hundred thirty seven patients had early gastric cancer and 536 had advanced gastric cancer. The diagnostic performance between CT and EUS for the T staging showed no significant difference between CT and EUS for the kappa values. The kappa values showed moderate agreement at 0.4039 (P=0.021) and 0.4201 (P=0.026), respectively. This suggests that there is no difference between the two examinations for the overall T staging. Analysis of the discrimination of mucosal and submucosal lesions with EUS showed an accuracy of 58.92% and a Kappa value of 0.206 (P<0.001), suggesting fair agreement and a lower diagnostic performance than expected. To differentiate lesions with stages higher than or equal to T2 or T3 from the lesion with stages lower than T2 or T3, respectively, adoption of the higher stage from the CT staging or the EUS staging showed a larger AUC of 0.84 than that from either stage alone. The CT-derived node stage had the higher diagnostic performance (68.55%) than that of the EUS-derived node stage (60.82%) for the node staging. Conclusion: The CT-derived stage and EUS-derived stage showed comparable results for determining the T stage of gastric cancer. Yet the higher stage of the two stages from CT and EUS most accurately discriminated between those lesions with stages higher than T2 and those lesions with stages lower than T2.

  • PDF