• Title/Summary/Keyword: 곡률 반경

Search Result 331, Processing Time 0.026 seconds

A Study on theProperty of Seepage in the Curved Levee by Numerical Analysis (제방만곡부에서의 침투특성에 관한 수치해석적 연구)

  • Park, Choon-Sik;An, Byeong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.4
    • /
    • pp.5-17
    • /
    • 2021
  • In this paper, three-dimensional analysis of the curved levee was performed according to curvature angle, and radius of curvature to investigate the property of seepage. The hydraulic gradients in the curved parts of levees decreased in the outer levee and increased in the inner levee, compared to the two-dimensional analysis. The smaller the curvature angle and the radius of curvature, the larger the change of the hydraulic gradient, compared to the two-dimensional analysis. The effect of curvature radius on the hydraulic gradient was greater than the curvature angle. As a result of evaluating the piping safety factor for the critical hydraulic gradient, the safety factor was increased by 2~5% in the outer levee and decreased by 4~12% in the inner levee, compared to the two-dimensional analysis. Considering this reduction, if the two-dimensional analysis is performed on the curved part of the levee, and if designed the safety factor for piping is 0.1~0.3 greater than allowable FS=2.0, the safety factor of the curved part is slightly reduced, but there is no difficulty in securing stability.

Characteristics of Wave Overtopping with Flared Shaped Protection Wall (2중곡면 방파제의 곡면특성에 따른 월파제어효과)

  • Kim, Mun Jeong;Lee, Geun Il;Lee, Seong Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.218-218
    • /
    • 2011
  • 2중곡면 반파공의 월파 특성을 검토하기 위하여 입사파고 및 주기가 각각 다른 불규칙파를 대상으로 수리실험을 실시하였으며, 2중곡면 반파공과 직립형 구조물에 대해 동일한 조건으로 실험하여 이를 명확히 하였다. 특히 2중곡면 상부의 곡률반경에 따라 외해측으로 되돌리는 파랑의 비말효과에서 큰 차이가 있을 것에 착안하여 상부곡면부의 곡률반경이 증가한 정상 2중곡면 반파공(FSW)과 상부곡면부의 곡률반경이 감소한 역 2중곡면 반파공(IFSW)에 대해 실험을 수행하였다. 그리고 2중곡면 원호 크기의 비 B/D=0, 20%, 40%, 60% 및 80%인 경우에 대해서도 월파특성을 비교 검토하여 다음과 같은 결론를 얻었다. 1. 2중곡면 원호 크기의 비 B/D가 증가할수록 월파저지 효과가 개선됨을 확인 하였으며 최대 B/D가 0.8인 경우 0.2에 비해 50% 이상 월파유량이 감소하여 B/D의 변동에 따른 월파저지특성을 확인하였다. 2. 역2중곡면 반파공(IFSW)의 실험결과 기존 정상2중곡면 반파공(FSW)에 비하여 20%이상 월파량이 감소하고 있음을 알 수 있었으며 이는 2중곡면 상부측의 곡률 반경이 증가함에 따른 기하학적 특성에 의해 외해측으로의 되돌림 파랑(수괴)이 증가한 것으로 판단된다. 3. 동일한 마루높이에 대해 직립형 호안에 의한 월파량 비교결과 역 2중곡면 반파공(IFSW)의 경우 최대 80%이상의 월파량 저감 효과가 나타나는 것으로 검토되었다. 4. 월파저지의 측면에서 2중 곡면공에 비해 역2중 곡면공이 우수한 것으로 예측되었으나 2중곡면 반파공의 소파원리가 반파공의 원호내에서 쇄파를 야기하여 파에너지를 소멸하는 것이므로 쇄파를 유도하는 과정에서 충격쇄파압의 발생이 예측되는 바 이에 대한 계속적인 연구가 필요한 것으로 판단된다.

  • PDF

Improved method of lateral offset calculation for optical waveguide (광도파로의 곡률 반경에 따른 모드특성과 Lateral Offset 변화)

  • 박순룡;김우택;라상호;오범환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.408-412
    • /
    • 1998
  • As the radius of curvature of curved optical waveguide gets smaller, the loss increases at the junction of linear-curved waveguide by the cross sectional mode mismatch. The concept of lateral offset has been used widely to minimize it, and simple method of maximum matching has been efficient for most cases of silica waveguide with low optical confinement and large radius of curvature. Here, we analyzed that the propagation mode characteristics of the lateral offset and propagation mode characteristics of general case with effective index method and Airy function solution. As the normalized frequency varies, mode characteristics changes near the boundary of 1/V=0.7 and the simple matching of gaussian profile might give -35% of error at most. We proposed improved method with a new correction factor to improve the mode mismatch problem of conventional methods for general cases, and showed the convenience and feasibility of this method for the calculation of the lateral offset.

  • PDF

Study of Flexible Forming Process Involving the Use of Sectional Flexible Die for Sheet Material (분할가변금형을 이용한 박판의 가변성형공정 연구)

  • Heo, Seong-Chan;Ku, Tae-Wan;Song, Woo-Jin;Kim, Jeong;Kang, Beom-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.299-305
    • /
    • 2010
  • In general, the flexible forming die that has been used in the flexible forming process has the identical punch size; hence, its flexibility is relatively low because the range of allowable curvature radii is limited due to the uniform punch tip radius. Hence, a conceptual design of a sectional flexible die is presented for enhancing the flexibility of the forming process. Two punches of different sizes are used to configure the arbitrary forming surface. For a forming region with a relatively large curvature radius, a large punch array block is used; on the other hand, for the forming regions with small curvature radii, a small punch block is used. The cross-sectional profiles are compared with the target shape for evaluating the effectiveness of the process. Consequently, it is confirmed that the sectional flexible die can be used along with a combination of punch blocks of different sizes for manufacturing objective surfaces of complex shapes.

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

A Study on the Proper Scope for Pressure Angle, Ratio of Tooth Number & Radius of Curvature in Non-Circular Gears (비원형기어에서의 압력각과 잇수비 및 곡률반경의 적정범위에 관한 연구)

  • Park, S.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.52-63
    • /
    • 1997
  • Non-circular gear has a good velocity ratio in high speed and heavy load without any slip, moreover, it can transmit various motion, using simpler structure than link and cam, automation mechainism. In case of designing and manufacturing non-circular gear. I suggest one of references in applying non-circular gear to industrial plant, and suitable range of application by pressure angle curvature and angle ratio

  • PDF

Measurement of Long Radius of Curvature by Using Bidirectional Shearing Interferometer (양방향 층밀리기 간섭계를 이용한 긴 곡률반경 측정)

  • 이윤우;조현무;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.198-203
    • /
    • 1994
  • An improved method for the measuement of very long radius of curvature by using a bidirectional shearing interferometer in a noncollimated light beam is given. This method can be used for both lenses and surfaces with positive or negative power. Detailed analyses for optical arrangements and achievable accuracy are presented.sented.

  • PDF

Flow Characteristics for the Variation of Radius of Curvature in Open Channel Bends (만곡수로에서의 곡률반경 변화에 따른 흐름특성)

  • 윤세의;이종태
    • Water for future
    • /
    • v.23 no.4
    • /
    • pp.435-444
    • /
    • 1990
  • The flow characteristics varying with the rate of the radius of curvature to width (Rc/B) in open channel bends are investigated with a simplified numerical model, briefly. Secondary flow velocity and transverse bed slope are formulated from the equations of moment of momentum and force balance analysis, respectively. The conservation equations of mass and streamwise momentum are simplified by depth integration and its solution could be obtained form explicit finite difference method. Three sets of computer simulation are executed. The rates of Rc/B adopted in simulations are 2.7, 5.4, 8.1 , respectively. The terms analyzed in this paper are secondary flow velocity, streamwise velocity, the path of maximum streamwise velocity, deviation angle, and mass-shift velocity.

  • PDF

A Study on the Improvement of Technical Regulation in the Customer Cabling System Using Optical fiber for FTTH (FTTH 도입을 위한 광선로설비 기술기준 개선 연구)

  • Choi, Mun-Hwan;Cho, Pyoung-Dong;Kang, Young-Heung;Yang, Jun-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7C
    • /
    • pp.529-533
    • /
    • 2008
  • In this paper, we have analysed the channel loss characteristics of optical fiber due to the changing of radius of curvatures and the number of cable banding, and due to the connection between different modes of fiber to derive revisions of technical regulation for FTTH. The results of test show that all conditions are satisfied the criteria(allowable radius of curvatures, 30mm) with the exception of conditions of 10mm radius in single mode case and show that source of light in multi mode fiber can't be delivered to single mode fiber. henceforth, we should study more intensively on the standards of connection between cables in the different modes.

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.