Structure-borne Noise Reduction of Pump Machineries for Naval Ships (함정용 펌프류 장비의 고체음저감)

  • Kim, Hyeon-Sil;Kim, Jae-Seung;Gang, Hyeon-Ju;Kim, Sang-Ryeol
    • 연구논문집
    • /
    • s.29
    • /
    • pp.83-90
    • /
    • 1999
  • In naval ships, pump machineries are the major sources of airborne and structure-borne noise. Noise is critical issue in ships not only it causes annoyance to crews, but also it can increase the underwater radiated noise, which is crucial in anti-submarine warfare. In present study, it is discussed the reduction of structure-borne noise of pump machineries by showing several examples. The most typical and effective solution is to use double resilient mount system. However, in cases where double resilient system cannot be applied due to space and weight increase, rubber pad can be used to reduce the structure-borne noise. In principle, the concept of structure-borne noise reduction is the same as that of vibration isolation.

  • PDF

Structure-borne Noise Analysis of Marine Diesel Engine Considering Receptance of Hull Structure at Mounting Point (선체 마운트 지지점에서의 리셉턴스를 고려한 선박용 디젤 엔진의 고체전달음 해석)

  • Jang, Seong-Gil;Jeong, Weui-Bong;Hong, Chin-Suk;Bae, Soo-Ryong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.120-128
    • /
    • 2011
  • This paper presents an efficient method to analyze noise and vibration of marine diesel engines mounted on flexible hull structure. The analysis model should in general include the hull structure, leading to lots of computational efforts. To minimize the computational efforts, in this paper, the transfer synthesis utilizing the receptance at the mounting points is proposed. The procedure is then verified by comparing the results with those from the full model calculation. The effects of flexible hull structure on the acoustic power from engine block are finally investigated. It is found that the effect of the hull is significant when the receptance of hull structure is similar to or greater than that of mount or engine block.

The Verification on Effect of Sound Absorption Tunnel for Elevated Railway (고가철교 방음터널 효과검증)

  • Kim, Hyung-Doo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.122-127
    • /
    • 2008
  • The source of wayside noise for the train are the aerodynamic noise, wheel/rail noise, and power unit noise. The major source of railway noise is the wheel/rail noise caused by the interaction between the wheels and rails. The Structure borne noise is mainly a low frequency problem. The train noise and vibration nearby the elevated railway make one specific issue. The microphone array method is used to search sound radiation characteristics of elevated structure to predict the noise propagation from an elevated railway. In this paper, the train noise and structure borne noise by train are measured. From the results, we investigated the effect on the sound absorption tunnel for elevated railway.

A Study on Mount Performance for Structure-Borne Noise Reduction in Resiliently Mounted System (탄성지지된 시스템의 마운트 고체음저감 성능에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2E
    • /
    • pp.50-55
    • /
    • 2007
  • SBN (Structure-Borne Noise) reduction in resiliently mounted machineries are predicted by using mass-spring model and wave model. In mass-spring model, mount is modeled as a spring, while in wave model, mount is considered as an equivalent elastic rod for taking account into longitudinal wave propagation. The predictions for SBN reduction through mounts are compared to the measurements for four different pumps. It is found that the mass-spring model is valid only in low frequency range below few hundred Hz, while for high frequency ranges longitudinal wave propagation in the mount must be considered to explain the measurements. It is also shown that impedance of the floor slightly affects low frequency behaviour in mass-spring and wave model below 50 Hz - 80 Hz, so that in engineering practice the effect of floor impedance may be neglected in computing mount performance.

A Study on Structure-Borne Noise Reduction for Resiliently Mounted Pumps for Ship (탄성지지된 박용 펌프의 고체음저감에 관한 연구)

  • Kim, Hyun-Sil;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.5
    • /
    • pp.488-495
    • /
    • 2007
  • In this paper, SBN (Structure-Borne Noise) reduction of resiliently mounted machinery and effect of the foundation impedance on mount performance is studied. SBN reduction through the mount is analyzed by using two theoretical models; mass-spring model and wave model, in which longitudinal wave propagation is included. It is found that floor impedance greatly affects SBN reduction through lower mount, while it is almost negligible to SBN reduction through upper mount. Comparisons between measurement and predictions shows that the mass-spring model is valid only in low frequency range below few hundred Hz, while for high frequency ranges longitudinal wave propagation in the mount must be considered.

Kinetics of esterification of food waste oil by solid acid catalyst and reaction optimization (고체 산 촉매를 이용한 고산가 음폐유의 에스테르화 반응 동역학 연구 및 반응 최적화)

  • Lee, Hwa-Sung;Lee, Joon-Pyo;Lee, Jin-Suk;Kim, Deog-Keun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.683-693
    • /
    • 2017
  • Transport biofuels have been recognized as a promising means to resolve the following issues like global warming, oil depletion and environmental pollutions. Among various biofuels, biodiesel has several advantages such as less emission of air pollutants and higher cetane values compared to diesel oil. Demand for biodiesel in Korea is increasing that leads to higher dependence on the imported feedstocks. Therefore, it is important to utilize the waste materials collected domestically for biodiesel production. Food waste oil collected in waste treatment facility has not been used for biodiesel production due to high free fatty contents in the oil. In this work, biodiesel conversion of food waste oil by Amberlyst 15 was studied. Synthetic and actual food waste oils have been used in the study. First, the effects of the major operating parameters including reaction temperature, methanol to oil molar ratio and catalyst loading on the conversion rates and yields were determined with synthetic waste oil. Kinetic modelling work was also done to determine the activation energy of the reaction. From the work, optimization reaction conditions were determined to be 383K, 1: 26.1 for methanol molar ratio to oil, 10 wt.% for catalyst loading and 360 min for reaction time. Activation energy of the reaction is determined to be 29.75 kJ/mol, lower than those reported in the previous works. So the solid catalyst, Amberlyst 15, was more efficient for esterification than the solid catalysts employed in the other works. Agitation rates have the negligible effects on the conversion rates and yields. With the identified optimization conditions, conversion of the actual food waste oil was also carried out. The esterification yield of actual food waste oil in 60 min was 13% lower than that of synthetic waste oil but the final yields in 240 min were similar each other, 98.12% for synthetic oil and 97.62% for actual waste oil.

New Mount with Moving-Coil-Type Electromagnetic Actuator for Naval Shipboard Equipment (가동코일형 전자기식 작동기를 결합한 함정 탑재장비용 마운트 개발)

  • Shin, Y.H.;Moon, S.J.;Jung, W.J.;Jeon, J.J.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.885-894
    • /
    • 2013
  • In this study, a new hybrid mount with a moving-coil-type electromagnetic actuator is developed to reduce the vibration transmitted from naval shipboard equipment to the ship hull structure. The detailed design of the hybrid mount is determined through several design stages with electromagnetic numerical analysis using Maxwell software. The hybrid mount, which combines a rubber mount with an electromagnetic actuator, has a fail-safe function for shock resistance. The mount is fabricated and tested using a universal testing machine to check the design specifications. Finally, control tests are carried out on the hybrid mount to confirm its performance and applicability.

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Integrated Superstructure Design of Elastic Components to Improve the Track Performance (궤도의 성능향상을 위한 탄성구성요소로 통합된 상부구조 설계)

  • Kang, Bo Soon
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.578-585
    • /
    • 2015
  • Track elastic components can be technically and economically efficient when integrated well into track superstructure of a railway network. In such cases, the elastic rail pad is larger than a 800m radius curve provides smooth rail branching and allows for high-speed operation ($V{\geq}160km/h$). High track resistance causes the tamping intervals to stand out because the constantly increasing share of the sleeper pad further extends the increase of the tamping interval and the long grinding period; the engineering and construction of the small curve radius track provides some measures for reducing the solid sounds. Installation of elastic mats under the ballast can have a good effect, particularly in the context of protection against dust during construction or extensive renovation measures when laying new lines. However, such a process requires special attention and proper installation.

Estimation of Vibrational Power Transmitted from Vibration Source to Supporting Structure - Estimation and Measurement of Vibrational Power Transmitted in the Horizontal Direction - (진동원으로부터 지지구조물에 전달되는 진동 파워의 추정 - 수평방향으로 전달되는 진동파워의 추정 및 측정 -)

  • 김재철;주진수
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1137-1143
    • /
    • 1998
  • This paper describes the method to measure of the vibrational power transmitted from the vibration source to the supporting structure in the horizontal direction. Generally, it is impossible to measure horizontal forces at the coupling points. However. the vibrational Power transmitted in the horizontal direction can be measured by using indirect method that is based on the mechanical impedance and velocities at the coupling points. We proposed the method to estimate the vibrational power when the vibration source and supporting structure cannot be separated. In this paper. the vibrational power transmitted in the horizontal direction is also estimated by using this method. The estimated and measured results of the mobilities at the coupling point and vibrational power in the horizontal direction are compared. It is shown that the estimated results agree well with the measured results. For the supporting structure with multiple coupling points, the other coupling points should be considered for measuring the vibrational power transmitted through one coupling points. We examine the effects of other coupling points and measure the vibrational power without considering the other coupling points.

  • PDF