• Title/Summary/Keyword: 고조

Search Result 3,293, Processing Time 0.032 seconds

A Study on the Harmonics Evaluation of Extra High Voltage Customers by Field Tests (실측에 의한 특고압 수용가의 고조파 평가에 관한 연구)

  • Kim, Kyung-Chul;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.50-55
    • /
    • 2007
  • A large steel industry which has nonlinear loads including electric arc furnaces is one of the extra high voltage customers. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative propablistic approach is the most commonly used method to solve time varying harmonics. In this paper the in varying harmonics of electric arc furnace loads are evaluated by international harmonic standards(IEC 61000-3-6, IEEE 519 and JIS C 61000-3-2).

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

Effect of Harmonics on Residual Current Protective Devices (고조파가 누전차단기에 미치는 영향)

  • Jeon, Jeong-Chay;Lee, Sang-Ick;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.84-89
    • /
    • 2006
  • Tripping of residual current protective devices(RCPDs) caused by harmonics has been continuously reported, but no literature is available on the behavior of RCPDs caused by harmonics. This paper, in order to find out the effects of harmonics on RCPDs, investigated the present condition on malfunction of RCPDs and measured harmonics at buildings where nuisance tripping of RCPDs was often occurred. Also, the operational characteristics of RCPDs were tested by the harmonics synthesizer that can generate distorted waveform. Results of experiment detected that there was minimum tripping current of RCPDs when third harmonic added to the fundamental frequency. And it was found that the leakage current to cause tripping of RCPDs increased with more higher order harmonics added to the fundamental frequency.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

전력계통에서의 고조파 개선 사례 연구

  • Kim, Gyeong-Cheol;Gang, Chang-Won;Han, Jong-Yeong;Lee, Jin-Seok;Han, Seong-Bae
    • Electric Engineers Magazine
    • /
    • v.216 no.8
    • /
    • pp.28-33
    • /
    • 2000
  • 최근 power electronics 응용 기기의 사용증가로 비선형 특성부하에 의한 고조파가 상당히 발생하고 있으며 고조파에 의한 영향이 심각한 수준에 이르고 있다. 빌딩의 인텔리전트화에 의한 OA기기 및 자동화에 따른 다량의 고조파가 변압기 과열, 중성선과열, 소음, 진동, Noise 등의 현상으로 나타나고 있으며 공장의 전력변환장치 사용증가에 따라 지금까지 고려되지 않았던 여러 가지 현상이 나타나고 있다.

  • PDF

Studies on the Particular harmonics Elimination inverter Magnetron drive (마그네트론 구동용 인버터의 특정 고조파 제거에 관한연구)

  • Kim, Yang-Bea;Hwang, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1296-1297
    • /
    • 2015
  • 마이크로 웨이브를 사용하는 기기들은 대량생산 공정에 있어서 식품 가공용 건조기기로 사용되고 있다. 3kW 마그네트론을 구동하기 위해서는 필라멘트를 가열하고 고압의 DC전원을 발생할 수 있는 회로가 필요하게 된다. 반도체 소자를 이용한 전력변환 장치로 DC로 운전이 되면 AC계통으로 혼입되는 고조파가 발생된다. 본 논문에서 AC계통으로 유입되는 특정고조파 제거 방법을 제안한다. 고조파 검출회로를 기반으로 전류를 제어함으로써 기존 LC필터에서 제거되지 못한 고조파성분이 감쇠되는 성능을 보였다.

  • PDF

공정 플라즈마 진단을 위한 고조화파 분석법 및 진단 결과

  • Jeong, Jin-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.29-29
    • /
    • 2011
  • 플라즈마 진단법은 플라즈마를 분석 및 이해하는데 매우 중요하다. 최근 플라즈마 쉬스의 비선형성을 이용한 고조화파 분석법이 개발되었다. 플라즈마 쉬스에 정현 전압을 인가하면, 쉬스의 비선형성 때문에 고조화 전류들이 발생하게 되는데, 이 고조파 전류들을 분석하면 플라즈마밀도와 전자 온도를 측정할 수 있다. 이 방법은 실시간 또는 고속으로 플라즈마 측정이 가능하고, 부도체 탐침을 사용할 수 있기 때문에, 식각 또는 증착 플라즈마에서는 측정이 가능한 장점이 있다. 본 발표에서는 진단법의 원리와 공정 플라즈마 장비에서 진단 결과들을 소개하고자 한다.

  • PDF

Harmonic Elimination Technique using Digital Software controlled NPC PWM Inverter (디지틀 소프트웨어 제어 NPC PWM 인버어터를 이용한 고조파 제거 기법)

  • 윤병도;김윤호;김철우;송언빈
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.5
    • /
    • pp.43-50
    • /
    • 1993
  • 본 논문에서는 인버어터의 출력 파형에 포함되는 고조파를 제거하기 위하여, 디지틀 소프트웨어에 의한 NPC(Neutral Point Clamped) PWM 인버어터 제어기법을 제시하였다. 제안한 기법은 고조파 전류율과 파형 왜율을 낮출 수 있고, 인버어터의 성능을 크게 개선할 수 있다. 주파수 비를 36으로 하고, 변조지수를 1.2∼2.0의 범위에서 제어하였을 때, 대부분의 고조파 성분을 제거할 수 있고 기본파 성분의 크기를 최대로 출력할 수 있다.

  • PDF

A Study on PWM Inverter to control Fixed Total Harmonic Distortion (고조파 왜율의 일정 제어를 위한 PWM 인버터에 관한 연구)

  • Song, Eon Bin
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.130-130
    • /
    • 1995
  • 이 논문은 인버터의 출력파형에 포함되는 고조파 성분들을 제거하기 위한 PWM인버터의 소프트웨어 제어기법을 제시하고 있다. 제안한 기법에 의하면, 가변속 운전이나 무정전 전원 공급 시스템 응용시 인버터 출력의 고조파 왜율을 일정하게 낮출 수 있어 인버터의 성능을 크게 향상시킬 수 있다. 주파수 비36, 변조지수 1.2∼2.0인 제어모드에서 본 인버터는 고조파 왜율을 5[%]이내의 범위에서 운전할 수 있다.