• Title/Summary/Keyword: 고정자권선절연

Search Result 108, Processing Time 0.037 seconds

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

Conditioning diagnosis & on-line monitoring technology on the traction motor for railway rolling stock (철도차량 견인전동기의 상태진단 및 상시감시 기술)

  • Wang, Jong-Bae;Hong, Seon-Ho;Kim, Sang-Am;Kwak, Sang-Rok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.92-95
    • /
    • 2003
  • 본 논문에서는 철도차량 견인전동기에 대한 상태진단 및 상시감시 기술에 관하여 소개하였다. 권선의 절연상태 진단을 위한 비파괴 시험법에서는 부분방전량 Q에 대한 평균열화도 $\Delta$로 표현되는 D-Map에 의해 잔여 절연내력(residual dielectric strength)을 예측하고, 기기의 운전이력측면에서 기동-정지 횟수와 열적, 전기적 및 열싸이클 스트레스 등에 의해 각 열화 인자를 고려한 운전시간에 기반한 N-Y 수명예측을 수행한다. 그리고 견인전동기의 전류에 대한 온라인 상태감시를 통해 베어링 고장, 고정자 및 전기자 고장, 고장 또는 전동기축 손상에 기인하는 비정상 운전상태 의 감지를 수행한다.

  • PDF

Analysis of Insulation Characteristics for High-voltage Motor Stator Winding using Insulation Diagnostic Test (절연진단법을 이용한 고전압전동기 고정자권선의 절연특성분석)

  • Oh, Bong-Keun;Kang, Hyun-Goo;Kim, Hyun-Il;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.404-405
    • /
    • 2009
  • Insulation diagnostic tests for high voltage motor stator winding were conducted to analyze the insulation characteristics. Test motors were manufactured same factory and year(1996). Insulation characteristics of moisture winding are different from those of deteriorative winding. Insulation resistance and disscipation factor test results are sensitive to moisture winding. AC current, disscipation factor tip-up and PD test results are sensitive to deteriorative winding. Also, Capacitance value for stator winding insulation material has characteristic of increasing in moisture winding.

  • PDF

Statistical Analysis of Diagnosis Data for High Voltage Rotation Machine (고압회전기 진단데이터의 통계적분석)

  • Kim, H.I.;Jang, J.H.;Lee, S.H.;Byun, D.G.;Lee, K.H.;Sun, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2027_2028
    • /
    • 2009
  • 본 연구에서는 한국수자원공사 고압회전기 고정자권선 절연체의 진단데이터에 대한 통계적 분석연구에 관하여 설명하고 있다. 10년 이상 수집된 진단데이터를 사용하여 와이블 함수를 이용한 누적확률을 구하였으며, 그 결과로부터 각 진단항목에 대하여 형상모수와 절연상태를 판정하는 진단기준치를 제시하였다. 그 결과로 수력발전기의 대지간 전압에 대한 부분방전량의 기준값으로 10,000pC이하를 제시하였다.

  • PDF

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

A Study on Insulation Property of VPI Type Generator Stator Winding Through the Case Analysis of Insulation Breakdown (절연파괴 사례분석을 통한 진공함침 방식 발전기 고정자권선의 절연특성 연구)

  • Kong, Tae-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.311-316
    • /
    • 2010
  • According to increase of combined cycle power generation, the manufacturing market of gas turbine generator has become more competitive, so there is high pressure on the manufacturer to reduce generator price. Global VPI(vacuum pressure impregnation) method is effective to save the production cost and time for manufacturing stator windings, but it has an abrasion problem by vibration between stator windings and slots. This paper presents the insulation breakdown case, which is for VPI type generator during high voltage insulation tests, and also shows the cause analysis, repair works as well as reliability test. the purpose of this paper is to understand the insulation properties of VPI type generator and to know prevention of insulation weakness.

Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

A Stydy on the Development of Mica/Epoxy Compisite Materials(3) (마이카/에폭시 복합재료의 개발에 관한 연구(3))

  • 박정후;곽영순;정은식;신중홍
    • Electrical & Electronic Materials
    • /
    • v.1 no.2
    • /
    • pp.115-125
    • /
    • 1988
  • 지금까지 발전기 전동기 및 전력용 변합기와 같은 중전기에 사용되고 있는 복합절연재료인 유리섬유 강화프라스틱은 단가가 높고, 기계적 특성이 비등방성이며 기게적 응력이나 서어비스 중에 계면보이드의 발생으로 문제성이 제기되어 왔다. 이러한 결점을 해소하기 위하여 플레이크상의 필라에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 대표적인 플레이크상 재료인 마이카를 이용하여 현재 대형 발전기나 전동기의 고정자 권선 절연용으로 연구 개발되고 있는 마이카 페이프/에폭시 복합재료를 제작한 후, 이 재료의 전기적 및 기계적 특성과 최적 제작조건 등에 실험적으로 고찰하였다. 특히 아미노 실란 게면 결합제를 필라에 적용하여 시료의 전기적 및 기계적 특성에 미치는 효과를 검토하였다.

  • PDF

Analysis of Correlation Endwinding Breakdown and Insulation Test for Stator winding of Hydro-Generator (수력발전기 고정자권선의 단말부 절연파괴와 절연특성시험과의 관련성 분석)

  • Lee, D.L.;Lee, K.H.;Choi, K.N.;Kim, H.L.;Oh, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.103-105
    • /
    • 2005
  • The test were performed to analyze the cause of endwinding breakdown of hydro-generator which had been in service after being constructed 1971. we conducted insulation diagnostic tests and checked visual inspection and operating condition of protective relays. On the basis of these test results, this paper tried to present the importance of service environment for the generator stator winding.

  • PDF