• Title/Summary/Keyword: 고전압단자

Search Result 10, Processing Time 0.031 seconds

Reliability assessment of mica high voltage capacitor through environmental test and accelerated life test (마이카 고전압 커패시터의 환경시험과 가속 수명시험을 통한 신뢰성 평가)

  • Park, Seong Hwan;Ham, Young Jae;Kim, Jeong Seok;Kim, Kyoung Hun;So, Seong Min;Jeon, Min Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.270-275
    • /
    • 2019
  • Mica capacitor is being adopted for high voltage firing unit of guided weapon system because of its superior impact enduring property relative to ceramic capacitor. Reliability of localized mica high voltage capacitors was verified through environmental test like terminal strength test, humidity test, thermal shock test and accelerated life test for application to high voltage firing unit. Failure mode of mica capacitor is a decrease of insulation resistance and its final dielectric breakdown. Main constants of accelerated life model were derived experimentally and voltage constant and activation energy were 5.28 and 0.805 eV respectively. Lifetime of mica capacitor at normal use condition was calculated to be 38.5 years by acceleration factor, 496, and lifetime at accelerated condition and this long lifetime confirmed that mica high voltage capacitor could be applied for firing unit.

A Study on lgnition Voltage Control for Gasoline Engine Using Inverter (인버터를 사용한 가솔린엔진 점화전압 제어에 관한 연구)

  • 김광조;김남호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.74-79
    • /
    • 1997
  • 본 논문은 현재 사용되고 있는 가솔린엔진의 전기불꽃방전 점화장치의 점화전압에 대하여 조사하고, 점화전압을 엔진의 다양한 회전형태에 따라 적절하게 제어하는 방법에 대하여 연구하고 실험한 것이다. 기존의 점화장치는 고속회전에서는 통전시간의 제한으로, 그리고 기동시 에는 전지의 단자전압이 저하하여 높은 전기불꽃방전용 고전압을 얻을 수 없음으로 인하여, 고속성능이 저하하고 기동이 불확실해 진다. 이 실험에서 엔진의 회전형태에 따라 점화전압을 적절하게 제어함으로서 이러한 문제점들을 실용적으로 개선할 수 있음을 보여주었다.

  • PDF

전기분해법을 이용한 다이아몬드상 카본 박막 증착

  • Kim, Byung-Gyu;Kim, Eun-Mi;Kwon, Min-Chul;Kim, Yong;Lee, Jae-Yeol;Park, Hong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.94-94
    • /
    • 2000
  • 증류수(Distilled Water)와 메탄올(CH3OH)의 혼합용액을 전기분해하여 Si 기판위에 다이아몬드상 카본을 증찰하였다. Si 기판은 HF(16%) 용액으로 산화막을 제거하고, 전이금속 Co, Ni 박막을 증착시킨 후 전기 분해 장치의 전극 (-)단자에 연결하였다. (+)단자에는 순도 99%의 탄소 전극을 사용하였다. 기존의 에탄올, 에틸렌 글리콜(H2O-HOCH2CH2OH), 메탄올등의 전해질에 1000V 이상의 고전압을 인가하는 방법대신 메탄올과 증류수, 그리고 암모니아수(NH4OH)의 비를 달리하는 혼합액을 전해질로 사용하였다. 그결과 낮은 전압 (800V 이하)과 낮은 온도(6$0^{\circ}C$ 미만)에서도 다이아몬드상 카본을 증착할 수 있었다. 증착한 시료와 용액은 XRD, SEM, FT-IR 등을 이용하여 분석하였다.

  • PDF

Contact Stress Analysis of Stick Type Ignition Coil Jacket PBT (Stick Type Ignition Coil Jacket PBT의 접촉응력해석)

  • Kim Yangsul;Kim Namsu;Lee Jongseok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.45-50
    • /
    • 2005
  • Stick type ignition coil(called a Cigar coil) is a kind of transformer for an automobile modulaized of distributer and electric cable. A material of cigar coil is PBT $GF30\%$ resin. This is an excellent engineering plastic with both mechanical and electrical properties. When we insert an HV terminal into the PBT $GF30\%$ resin jacket, it breaks the jacket, because the HV terminal is bigger than the jacket. It is a fatal on durability of a part. In this study, We used ANSYS FEM tool in order to stress analysis by contact. In order to automatically estimate possible maximum diameter of an HV terminal, we used an APDL. In the contact part, we considered the relation of the HV terminal's diameter with the amount of stress that occurred. This relation is able to be applied, in part, to the dimensions of the part design.

Filed Programmable Logic Control and Test Pattern Generation for IoT Multiple Object switch Control (사물인터넷 환경에서 다중 객체 스위치 제어를 위한 프로그래밍 가능한 로직제어 및 테스트 패턴 형성)

  • Kim, Eung-Ju;Jung, Ji-Hak
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.1
    • /
    • pp.97-102
    • /
    • 2020
  • Multi-Channel Switch ICs for IoT have integrated several solid state structure low ON-resistance bi-directional relay MOS switches with level shifter to drive high voltage and they should be independently controlled by external serialized logic control. These devices are designed for using in applications requiring high-voltage switching control by low-voltage control signals, such as medical ultra-sound imaging, ink-jet printer control, bare board open/short and leakage test system using Kelvin 4-terminal measurement method. This paper describes implementation of analog switch control block and its verification using Field programmable Gate Array (FPGA) test pattern generation. Each block has been implemented using Verilog hardware description language then simulated by Modelsim and prototyped in a FPGA board. Compare to conventional IC, The proposed architecture can be applied to fields where multiple entities need to be controlled simultaneously in the IoT environment and the proposed pattern generation method can be applied to test similar types of ICs.

A Study on Chopper Circuit for Variation of Inductance and Threshold Voltage based on IGBT (IGBT 기반 인덕턴스 및 문턱전압 변화에 따른 초퍼 회로의 연구)

  • Lho, Young-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.504-508
    • /
    • 2010
  • The development of high voltage Insulated Gate Bipolar Transistor (IGBT) have given new device advantage in the areas where they compete with conventional GTO (Gate Turnoff Thyristor) technology. The IGBT combines the advantages of a power MOSFET (Metal-Oxide Semiconductor Field-Effect Transistor) and a bipolar power transistor. The change of electrical characteristics for IGBT is mainly coming from the change of characteristics of MOSFET at the input gate and the PNP transistors at the output. The change of threshold voltage, which is one of the important design parameters, is brought by charge trapping at the gate oxide under the environment that radiation exists. The energy loss will be also studied as the inductance values are changed. In this paper, the electrical characteristics are simulated by SPICE, and compared for variation of inductance and threshold voltage based on IGBT.

A study of sensitive reduction from cable when off-line partial discharge measuring (OFF-LINE 부분방전 측정 시 CV케이블에 의한 방전량 감도저하 현상 고찰)

  • Yi, Jong-Seuk;Lee, Eun-Chun;Chae, Ji-seog;Ham, Dong-Younf;Ok, Yeon-Ho;Byun, Du-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1177-1178
    • /
    • 2015
  • 국내 전력설비는 70년대 이후 제3차 경제개발 5개년 계획에 따라 중화학공업의 발전과 함께 급속히 성장해왔다. 과거 개발 위주의 산업구조에서 급속히 팽창한 전력설비는 21세기에 들어서면서 30~40년 장기 사용에 따른 노후화가 진행되었고, 증가하는 전력수요에 대응하기 위한 발전 및 송전 용지 확보의 어려움으로 인하여 전력설비의 신규 증설에 많은 어려움을 격고 있는 실정이다. 따라서 전력설비의 안전성과 신뢰성을 확보하기 위해 적절한 교체시기 선정 및 최적의 자산관리 필요성에 대해서 최근 관심을 가지기 시작하였고, 이러한 전력설비의 최적 자산관리에 핵심적인 전력설비의 상태평가 기술의 발달로 과거 시간기준의 유지보수(Time Based Maintenance)에서 최근 노후설비의 증가와 진단기술의 발달에 따른 예방보전(Preventive Maintenance)에 의한 상태기준 유지보수(Condition Based Maintenance)개념으로 전환되고 있다. 고전압 회전기기(발전기, 전동기)의 상태평가를 위한 핵심기술인 Off-line 부분방전시험이 널리 적용되고 있으며, 본 논문에서는 부분방전 측정 시험 시 대상설비 단자부의 인출케이블에 의한 감도저하 현상에 대해 고찰 하였다.

  • PDF

A Study on Improvement of Storage Safety through Quality improvement of Torpedo Propulsion Battery (어뢰 추진전지 품질개선을 통한 저장안정성 향상에 관한 연구)

  • Jang, Min-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.291-298
    • /
    • 2019
  • We describe the improvement of insulation performance and the prevention of electrolyte leakage in a single cell in order to prevent the fuming phenomenon caused by leakage of electrolyte in a lithium secondary battery in a submerged weapon (torpedo) operated in Korea. A torpedo using lithium secondary battery as a main power source (propulsion battery) can induce the heat and fuming phenomenon, which makes it inconvenient for naval equipment operation in Korea. In the simulation test, the electrolyte of some battery cells leaked in the battery pack unit, leading to a short circuit between the main power circuit and the terminal tab of the high voltage part. We analyzed the characteristics and mechanism of the lithium secondary battery during this heat generation and fuming phenomenon. In order to prevent leakage of the electrolyte in the lithium secondary battery, the design was improved via fundamental (terminal tap enhancement) and complementary (insulation block selection and installation) measures. Comparison of the performance test before and after the improvement showed that the tensile strength of the tap terminal was improved about 2 times and the withstand voltage characteristic was improved. The application of quality improvement measures resulted in no fuming even after more than 3 years of field operation. This result is expected to improve the operation and storage stability of the torpedo propulsion cell.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF