• Title/Summary/Keyword: 고온 저온 시험

Search Result 179, Processing Time 0.025 seconds

Study on Thermal Environmental Test for XKT-1 (KT-1 Export Version) Aircraft (XKT-1(수출형 KT-1) 항공기 열 환경시험에 관한 연구)

  • Kim, Jinseog
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2021
  • This paper delineates the applied thermal environmental test profiles using test conditions and procedures based on MIL-STD-810 Method 501 (High Temperature Test Method) and Method 502 (Low Temperature Test Method). The test profiles have been optimized in order to comply with export customer's requirements and product reliability in high and low temperature environment for XKT-1 (KT-1 Export Version) aircraft. Additionally, the tests are suitable for large sized environmental chambers, which is one of the facilities of ADD (Agency for Defense Development) according to ETEMP (Environmental Test and Evaluation Master Plan). The results of these test profiles and test executions satisfy the customer requirements and product reliability. The present paper can be applied to the other export programs with more severe temperature conditions.

A study on the temperature guidelines of weapon systems test & evaluation in the coastal environment of the Korean peninsula (한반도 연해안지역 환경시험기준의 테일러링을 위한 온도기준 설정에 관한 연구)

  • Yun, Songhyun;Kim, Siok;Cho, Yuseup;Hong, Yeonwoong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.6
    • /
    • pp.1437-1445
    • /
    • 2017
  • This paper suggests a temperature guidance which must be addressed in the preparation of specifications for military equipment used in ocean/coastal environment of the Korean peninsula. It would often be costly to design materiel to operate under the most extreme environmental conditions ever recorded. Therefore, military planners usually accept equipments designed to operate under environmental stresses for all the time except a certain small percentage of the time. In this study, an 1-percent frequency of occurrence is recommended. Pohang and Shineiju are chosen to represent the hottest and coldest regions, respectively, based on surface weather observations among 28 costal regions from 1904 to 2015. The 1st and 99th percentile temperatures for Pohang and Shineiju are $37.7^{\circ}C$ and $-23.7^{\circ}C$, respectively. Diurnal cycles, including solar radiation, relative humidity and wind-speed are also provided.

자동차용 강판의 온도에 따른 기계적 특성

  • Hyeon, Ju-Sik;Lee, Bo-Ryong;Mun, Man-Bin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.39.1-39.1
    • /
    • 2010
  • 겨울철 혹한지방에서의 차량운행 또는 여름철 혹서지방에서의 장시간 차량 운행시 차체를 구성하고 있는 강판에는 약 $-50^{\circ}C{\sim}150^{\circ}C$의 온도환경에 처하게 된다. 따라서 이러한 저온 고온 환경하에서 차체 충돌상품성 예측 및 충돌안전 설계를 위해 온도에 따른 차체 강판의 기계적 물성평가가 요구된다. 이를 위해 본 연구에서는 자동차용 충돌부재에 주로 쓰이는 HS440MPa, HS590MPa급 냉연 고장력 강판에 대해 $-60^{\circ}C{\sim}200^{\circ}C$의 온도범위로 저온 고온 인장시험을 수행 하였다. 각각의 인장시험 결과로부터 온도 별 항복강도, 인장강도, 연신율, 가공경화지수 등 기계적 물성 변화를 평가하였다. 저온 고온 인장시험은 ZWICK Z250 만능재료시험기를 사용하였고 KS5호 규격의 인장시편을 사용하였으며, 시편에 충분한 온도를 가하기 위하여 목표온도 도달 후 20분간 유지한 뒤 인장시험을 수행하였다. 인장시험결과 HS440MPa, HS590MPa급 두 강종 모두 온도가 낮아질수록 강도 및 연신율 등이 증가하였고, 온도가 증가할수록 강도 및 연신율 등 기계적 물성이 저하 되었다. 즉, 우리가 주로 평가해왔던 상온($25^{\circ}C$)에 비해 저온 고온 환경하에서는 강판의 기계적 물성 변화가 큰 것을 알 수 있다. 따라서 혹한 또는 혹서 지방 등 온도차이가 큰 운행환경하에서의 차체 강도 및 충돌안전성 확보를 위해 온도에 따른 강판의 정확한 물성평가가 필요하고 차체 설계시 온도에 따른 강도변화를 충분히 고려하여야 한다.

  • PDF

A Study on Design of the Temperature Testing Equipment Malfunction Monitoring System (온도시험 장비 오류 감시 시스템 설계에 관한 연구)

  • Yoon, Myung-Seob;Park, Koo-Rack
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.435-436
    • /
    • 2019
  • 본 논문에서는 첨단 정밀 전자장치의 신뢰성 시험을 위해 사용하는 온도시험 장비의 오동작이 발생이 되면, 시험담당자에게 문자메시지를 통해 현재 시험장비가 오동작 중임을 알릴 수 있는 시스템을 제안한다. 제안시스템은 기존에 오픈 소스를 이용한 시험장비의 오동작 여부를 모니터를 하는 시스템에 시험담당자에게 이 사실을 SMS로 전달하는 시스템을 추가한 것이다. 정밀 전자장치는 출고전에 온도시험 장비를 사용하여 설정한 저온, 고온 온도 상황에서 각각 정상적으로 장치가 동작하는지의 여부를 확인하게 된다. 만약 이 상황하에서 온도 시험장비가 설정한 저온의 온도 이하 혹은 설정한 고온의 온도 이상 등의 오동작이 발생되면, 수억원에 이르는 고가의 시험대상 제품이 손상을 입어 폐기하는 경우가 생긴다. 제안한 시스템은 시험 운용자가 자리를 비우는 야간에 특히 유용한 시스템으로서 온도시험장비와 별도의 전원을 사용하여 그 신뢰성을 높이는 장점을 가진다.

  • PDF

A study on the temperature guidelines for weapon system test and evaluation in the Korean peninsula (무기체계의 환경시험을 위한 한반도의 온도기준 설정에 관한 연구)

  • Moon, Jayoung;Kim, DongGil;Sung, InChul;Hong, YeonWoong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.6
    • /
    • pp.1593-1600
    • /
    • 2016
  • This paper suggests a temperature guidance for requirements which must be addressed in the preparation of specifications for military equipment used in land applications in the Korean peninsula. In general, the equipment should be designed to operate during all but a certain small percentage of the time. Daegu and Yangpyeong are the hottest and coldest regions by month, respectively, based on surface weather observations over 132 regions from 1904 to 2014. The 1-percent high and low temperatures for land environment in the South Korea are $38.7^{\circ}C$, and -$29.0^{\circ}C$, respectively. This paper also presents the temperature values occurring for specified frequencies of occurrence during the most severe month. Diurnal cycles associated with the hottest and coldest top one-percent temperatures, including associated solar radiation, relative humidity, and wind-speed are provided.

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

Varietal Differences in Growth and Development Affected by Temperature in Barley (대맥품종의 오도에 따른 생육반응)

  • 천종은;박문웅;김정곤;이은섭
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.4
    • /
    • pp.343-349
    • /
    • 1988
  • In order to get informations for breeding early barley cultivars, the thermosensitivity and low temperature growth ability about the breeding materials vernalized were tested at the high '||'&'||'amp; low temperature and field conditions. The temperature coefficient (Q10), ratio and thermosensitivity for plant height were various among cultivars versus temperature treatments. The early cultivars had greater Q10 values and insensitive responses to temperature changes. The Q10 and thermosensitivity for the time of flag leaf unfolding were various among cultivars, but the coefficient of variation in the thermosensitivity was greater, so the character would be more useful for investigating the varietal differences. The Q10 and thermosensitivity for plant height were not significantly correlated with Q10 and thermosensitivity for the time of flag leaf unfolding. The periods from heading to flowering were 2 to 4 days at the high temperature plot, but 1 to 11 days at the low temperature plot, showing much greater variations. In general the cultivars with greater difference of heading time between the high and low temperature plots were Suwon 218, SB 76588, Oweolbori, and Jogangbori, showing the sensitive thermophase and early heading.

  • PDF

Studies on the leaf discoloration caused by low temperature-Change of soluble protein components by temperature - (저온에 의한 수도의 Discoloration 발생에 관한 연구-온도에 의한 가용성단백질구성 변화에 관하여-)

  • Park, Kyeong-Bae;Tanaka, Takayuki;Harada, Jiro
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.1
    • /
    • pp.1-4
    • /
    • 1978
  • The change of soluble protein components in leaf discoloration of rice plant was investigated in the Growth Cabinet with various temperature conditions. The ratio between high molecular soluble protein and low molecular soluble protein was high under high temperature condition, while low under low temperature condition, and also lower in Indica type varieties than Japonica type variety.

  • PDF

Hygrothermal Effect on the Strength of Carbon/Epoxy Composite Single-Lap Bonded Joints (고온습도 및 저온 환경이 복합재 접착 체결부 강도에 미치는 영향 연구)

  • Song, Min-Gyu;Kweon, Jin-Hwe;Choi, Jin-Ho;Kim, Hyo-Jin;Song, Min-Hwan;Shin, Sang-Joon;Byun, Jai-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.119-128
    • /
    • 2010
  • The hygrothermal effect on the strength of composite single-lap bonded joints were investigated. The specimens were manufactured in four different manufacturing methods and tested in three different environmental conditions. An interesting result is that the strengths of the joints in the elevated temperature and wet (ETW) conditions were found to be 11 ~ 23% higher than those in the room temperature and dry (RTD) environment. In contrast, the strengths of the joints in the cold temperature and dry (CTD) condition decrease by 8 ~ 21% compared to those in the RTD environment except for cobonded joint. The difference in the strength by testing environments is mainly attributed to the change of the material properties of adhesive by temperature and moisture.

Electric Degradation of Failure Mode of Solar Cell by Thermal Shock Test (열충격 시험 후 태양전지 파괴 모드에 따른 전기적 특성변화)

  • Kang, Min-Soo;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.327-332
    • /
    • 2013
  • 일본 연구에서는 열충격 시험을 통한 태양전지의 파괴모드에 따른 전기적 특성을 분석하였다. 시편은 Photovoltaic Module을 만들기 전 3 line Ribbon을 Tabbing한 단결정 Solar Cell을 제작하였다. 열충격 시험 Test 1의 온도조건은 저온 $-40^{\circ}C$, 고온 $85^{\circ}C$, Test 2는 저온 $-40^{\circ}C$, 고온 $120^{\circ}C$에서 Ramping Time을 포함하여 각각 15분씩, 총 30분을 1사이클로 500사이클을 각각의 조건으로 수행하였다. 열충격 시험 후 Test 1에서는 4.0%의 효율 감소율과 1.5%의 Fill Factor 감소율을 확인하였으며, Test 2에서는 24.5%의 효율 감소율과 11.8%의 Fill Factor 감소율을 확인하였다. EL(Electroluminescence)촬영 및 단면을 분석한 결과, Test 1과 Test 2 시편 모두 Cell 표면 및 내부에서의 Crack이 발견되었다. 하지만, Test 2의 시험이 Test 1보다 가혹한 온도조건의 시험으로 인해 Test 1에서 나타나지 않았던, Cell 파괴를 Test 2에서 확인하였다. 결국, Test 1에서 효율의 직접적인 감소 원인은 Cell 내부에서의 Crack이며, Test 2에서는 Cell 내부에서의 Crack 및 Cell 파괴로 인한 Cell 자체의 성능저하로 효율이 크게 감소한다는 것을 본 실험을 통하여 규명하였다.