• Title/Summary/Keyword: 고온전이

Search Result 607, Processing Time 0.033 seconds

Partial Purification and Characteristics of Amylases from Herpetosiphon geysericola (Herpetosiphon geysericola 균주의 Amylase 부분정제 및 특성)

  • Jun, Yeong-Soo;Hong, Yong-Ki;Seu, Jung-Hwn
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.16 no.2
    • /
    • pp.128-135
    • /
    • 1987
  • Extracellular ${\alpha}-amylase$, ${\beta}-amylase$ and glucoamylase produced by a thermophilic and cellulolytic bacterium, Herpetosiphon geysericola CUM 317, were partially purified by salting out with ammonium sulfate and by chromatography on a DEAE-cellulose column and on a CM-cellulose column. The Km values of ${\alpha}-amylase$, ${\beta}-amylase$ and glucoamylase for potato starch were $2.31mg/m{\ell}$, $7.69mg/m{\ell}$, and $8.33mg/m{\ell}$. The molecular weights of ${\alpha}-amylase$, ${\beta}-amylase$ and glucoamylase were calculated to be about 84000 dalton, 76000 dalton and 80000 dalton, respectively.

  • PDF

The formation of thermally stable Nickle Germanide with Ti capping layer (Ti capping layer를 이용한 열적으로 안정한 NiGe 형성에 관한 연구)

  • Mun, N.J.;Choi, C.J.;Shim, K.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.138-138
    • /
    • 2008
  • Ti capping layer를 이용하여 NiGe의 열적 안정성을 향상시키는 연구를 수행하였다. N-type Ge(100) 기판에 30nm 두께의 Ni과 30nm 두께의 Ti capping layer를 E-beam evaporator를 이용하여 증착하고 $300^{\circ}C$에서 $700^{\circ}C$ 까지 30초간 $N_2$ 분위기에서 급속 열처리하여 Ni-Germanide를 형성하였다. XRD의 결과로부터 Ti capping layer 유무에 상관없이, 전 온도 범위에 걸쳐 NiGe 상이 형성된 것을 관찰할 수 있었다. 급속 열처리 온도에 따른 면저항 값을 측정한 경우, $300^{\circ}C$에서 $600^{\circ}C$까지의 열처리 온도 범위에서는 모든 시편들이 비슷한 면저항 값을 보인 반면, 열처리 온도가 $700^{\circ}C$ 이상에서는 Ti capping layer가 있는 시편이 Ti capping layer가 없는 시편보다 낮은 면저항 값을 갖는 것을 확인할 수 있었다. 이는 고온 열처리 시 Ti capping layer에 있는 Ti가 기판 방향으로 확산하여 NiGe grain boundary에 segregation 되고 그로 인하여 NiGe의 grain boundary 움직임을 억제하여 agglomeration 현상을 효과적으로 방지하였기 때문에 나타난 현상으로 사료된다.

  • PDF

A Numerical Simulation of Regenerative Cooling Heat Transfer for the Rocket Engine (로켓엔진의 재생 냉각 열전달 해석)

  • 전종국;박승오
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.46-52
    • /
    • 2003
  • This paper presents the numerical thermal analysis for regeneratively cooled rocket thrust chambers. An integrated numerical model incorporates computational fluid dynamics for the hot-gas thermal environment, and thermal analysis for the liner and coolant channels. The flow and temperature fields in rocket thrust chambers is assumed to be axisymmetric steady state which is presumed to the combustion liner. The heat flux computed from nozzle flow is used to predict the temperature distribution of the combustion liner As a result, we present the wall temperature of combustion liner and the temperature change of coolant.

고온 염기성 수용액에서 $TiO_2$가 Alloy 600과 Alloy 690의 응력부식파괴에 미치는 영향

  • 김경모;김홍표;이창규;국일현;김우철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.78-83
    • /
    • 1998
  • Alloy 600과 Alloy 690의 응력부식파괴(Stress corrosion cracking, SCC)에 미치는 TiO$_2$의 영향을 315$^{\circ}C$의 10%NaOH 수용액에서 RUB(reverse U-bend) 시편, C-Ring 시편과 CT(compact tension)시편을 사용하여 평가하였다. 시편은 alloy 600 MA(mill anneal), alloy 600 TT(thermal treatment) 그리고 alloy 690 TT로 제작하였다. SCC 시험은 탈산된 10%NaOH 수용액에 2 g/1 TiO$_2$를 첨가한 용액과 첨가하지 않은 용액에서 수행하였으며, 이 조건에서 분극곡선도 얻었다. SCC 시험시 시편을 부식전위로부터 +150 ㎷ 양극분극을 가하였다. 기준전극으로 external Ag/AgCl electrode를 사용하였다. Alloy 600 MA로 제작한 RUB 시편은 TiO$_2$가 없는 용액에서 5일 안에 벽 관통 균열을 보였으나 TiO$_2$가 첨가된 용액에서는 균열을 관찰할 수 없었다. TiO$_2$가 첨가됨에 따라 alloy 600과 alloy 690의 임계전류밀도는 크게 감소하였고 또한 부동태 전류밀도도 감소하였다. 부동테 영역에서 TiO$_2$가 있는 용액의 경우 여러 peak가 있는 반면에 TiO$_2$가 없는 용액은 peak가 뚜렷하지 않았다. 이런 결과는 TiO$_2$가 첨가점에 따라 active region에서도 안정한 부동태 피막이 존재한다는 것을 시사한다. 또한 TiO$_2$가 없는 경우 SCC가 잘 일어나는 영역에 존재하는 부동태 피막이 TiO$_2$ 첨가에 따라 repassivation kinetics 등의 성질이 변화한 것으로 판단된다.

  • PDF

Cold Spray 증착된 Cu의 전면전극 특성연구

  • Gang, Byeong-Jun;Park, Seong-Eun;Kim, Yeong-Do;Kim, Seong-Tak;Lee, Hae-Seok;Cha, Yu-Hong;Kim, Do-Yeon;Park, Jeong-Jae;Yun, Seok-Gu;Kim, Dong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.482.1-482.1
    • /
    • 2014
  • 고효율 셀 및 생산 단가 절감은 결정질 실리콘 태양전지에서 가장 중요시되고 있는 이슈이다. 그 중 박형 실리콘 웨이퍼를 사용하는 공정은 고효율 및 생산단가의 절감을 만족시킬수 있는 방안으로 개발되고 있으며, 전면 전극 재료인 Ag를 다른 금속 재료로 대체하는 방법 또한 단가 절감을 위한 방안으로 연구가 진행 중이다. 하지만 박형 웨이퍼를 기존 공정에 적용할 시 전후면 전극 형성을 위한 고온의 소성 공정 때문에 웨이퍼의 휨 현상이 문제가 되고 있다. Cu 금속 분말의 저온 분사법을 결정질 실리콘 태양전지 전면전극 형성에 적용할 경우, 박형 실리콘 웨이퍼에 적용하는 문제와 Ag 전극의 대체 전극 사용 문제를 동시에 해결할 수 있는 대안이 될 것으로 사료된다. 본 연구에서는 Cold spray법을 사용하여 결정질 실리콘 태양전지 에미터 위에 Cu 전면 전극을 형성하였으며 반복되는 증착 횟수에 따른 전기적 특성 및 형상학적 특성 등을 평가하였다. 전극 형성 전의 Cu 분말 크기는 1~10 마이크론 이었으며, 주사전자현미경을 이용하여 전극의 형상 및 종횡비를 측정하였다. 또한 transfer length method (TLM) 패턴을 실리콘 웨이퍼 표면에 형성하여 접촉 저항 특성 및 전극의 비저항을 평가하였다.

  • PDF

Study on Stability Enhancement of P-type ZnO Thin Film Properties (P-형 ZnO 박막 특성 안정성 향상에 대한 연구)

  • Nam, Hyoung-Gin;Cha, Kyung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.472-476
    • /
    • 2007
  • In this study, we investigated methods for p-type ZnO deposition as well as stability enhancement of its properties. The film was prepared by co-depositing AlAs and ZnO in a RF magnetron sputtering system. Property variation was monitored with photoluminescence and Hall measurements by stressing the films at $250^{\circ}C$ for various duration upto 144 hours. Results indicated that co-deposition is a useful method for p-type ZnO preparation. In particular, pre-treatment in 30% $H_2O_2$ for 1min was observed to be effective in reducing the property variation taking place during the subsequent high temperature processes.

  • PDF

A Study on Stability Criterion for Cryocooler Operating HTS Coils (냉동기운전 고온초전도코일의 안전성평가기준에 관한 연구)

  • Ishiyama, Atsushi;Kim, Seok-Beom;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.317-323
    • /
    • 2001
  • We investigated the stability of cryocooler-cooled high-temperature superconducting (HTS) coils by using a computer program based on FEM. In this study, the current at which "thermal runaway" occurs, which depends on the relationship between the cooling power of the cryocooler and the heat generation in HTS coils, was adopted as a stability criterion of cryocooler operating HTS coils. It was shown that cryocooler-cooled HTS coil was stable in operating current above the critical current from the numerical analysis results by HTS model coil. And also, if we efficiently remove the heat generation from HTS coils by potimizing heat drain, the ramp-rate limitation can be mitigated because the effect of AC loss by the current rise was too small. Furthermore, in the case of pulsed operation; the HTS model coil is ramped from zero to the peak value in one second and back to zero current in one second, such as the operation of SMES device, the peak value of poerating current is 1.5-2 times greater than that of the thermal runaway current.

  • PDF

The Survey and its Effect for Cooling Systems used in Dairy Cattle Farms in Gyeonggi (경기지역 젖소 농가 고온저감시설 활용 실태조사 및 축사내 온습도 변화)

  • Lee, Jun-Yeob;Choi, Hee-Cheol;Lee, Dong-Hyun;Woo, Saem-Ee;Ki, Kwang-Seok;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • This survey was conducted to give the basic information and temperature and humidity variation by cooling systems in dairy farms in Korea. A total of 36 farms were surveyed in Gyeonggi province with the general information of farms such as milk production, and milk quality, types of cooling systems, and its operation method of dairy farms. All of surveyed farms have cooling fan and some have 1 more cooling systems such as sprinkler, foggy systems, ventilation duct, and shower system. Although the indoor THI of cow house was decreased by either ventilation duct or foggy system during hot season, the range belongs to mild heat stress scale for dairy cows.

Measurement of Radiative Heat Flux Using Plate Thermometer (판열유속계를 이용한 복사열유속 측정 실험)

  • Park, Won-Hee;Yoon, Kyung-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.95-98
    • /
    • 2013
  • Plate thermometers are used for measuring the radiative heat flux in high-temperature surroundings. The heat flux is calculated from the temperature measured at the back surface of the stainless steel surface of the meter. Heat fluxes from a Schmidt-Boelter gauge are measured as reference heat fluxes. A combined conductive coefficient is introduced to consider the heat loss to insulation, conduction through the stainless plate depth, and conduction from the non-uniform temperature of the plate of the plate thermometer. This coefficient is obtained using the repulsive particle swarm optimization.

Changes in Sea Water Characteristics Due to Operation of Shihwa Tidal Power Plant (조력발전소 가동에 따른 시화 해역의 해수특성 변화)

  • Kang, Young Seung;Chae, Yeongki;Lee, Hyung Rae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.4
    • /
    • pp.219-235
    • /
    • 2013
  • In order to investigate the changes in sea water characteristics and stratification due to operation of Shihwa tidal power plant, three dimensional numerical model is used. In summer, the density of inner part of Shihwa Lake is more affected by salinity than water temperature due to fresh water discharge. Before tidal power plant operation, the sea water characteristics in Shihwa Lake shows relatively high temperature and low salinity. After tidal power plant operation, water temperature decreases slightly and salinity tends to increase in Shihwa Lake. Also, density increases and stratification tends to weaken by mixing with sea water.