• Title/Summary/Keyword: 고압수 접촉상태

Search Result 11, Processing Time 0.032 seconds

The Effects of High Pressure Water Contact State on Hydraulic Fracturing (고압수 접촉상태가 수압파쇄에 미치는 영향)

  • Lee, Sang Hun;Lim, Jong Se;Jang, Won Yil
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2016
  • The shale gas is emerging as one of the oil and gas resources which can replace the traditional oil and gas resources. As the shale layer where the shale gas is deposited has low permeability, the hydrofracturing method is required to improve the productivity. This study is designed to conduct the laboratory hydrofracturing test on the samples which are modeled after the drilling hole having the general drilling hole and spiral groove. And compare the initial fracturing pressure and fluid contact between them in order to the result of the hydrofracturing depending on the shape of the drilling hole. In addition, the results were compared with the numerical modeling values from 3DEC and they were also compared with the data from the advance researches. It was found from the study that rather than the contact area of the high pressures water, the force concentration depending on the form of guide hole was more effective in the hydrofracturing.

Design of Busbar Joint Condition Monitoring System (부스바 접촉부 체결상태 모니터링 시스템 설계)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.823-824
    • /
    • 2016
  • In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact of bus bar, deterioration of the contact resistance, overtemperatue of the bus bars. In this paper, we propose bus bar joints monitoring system with loose connection of bus bar, measuring the joint resistance of busbars and monitoring internal and external heat. The proposed system can be reduced the electrical accidents by maintenance of busbar joints and the temperature of the conductive contact surface of busbars.

  • PDF

우주발사체에 적용되는 지상 엄브리칼 체결장치의 구성과 기능

  • Kim, Yong-Uk;Kim, Dae-Rae;Lee, Jeong-Ho;O, Seung-Hyeop
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.151.1-151.1
    • /
    • 2012
  • 우주발사체와 발사지원설비를 연결하여 추진제 공급과 전기신호 송수신 등을 가능하게 하는 메커니즘을 엄브리칼 장치라고 한다. 국내 우주발사체의 경우 액체산소와 케로신을 추진제로 사용하며, 질소, 공기 및 헬륨 등의 가스를 밸브구동, 공간 퍼지, 추진제 가압에 이용한다. 본 논문에서는 우주센터의 발사대설비에 적용된 엄브리칼 장치 중 추진제 및 고압가스 공급을 위한 자동체결장치(auto coupling device)의 구성, 기능 및 발사 준비를 위한 프로세스에 대해 기술하고 있다. 자동체결장치는 발사체 하부 두 곳에 연결되며, 산화제 공급측의 체결장치(coupling device 1)와 연료 공급측의 체결장치(CD 2)로 구성된다. 이 장치는 발사체와의 접촉면에서 기밀을 확보한 상태에서 내부의 탱크, 밸브, 인터스테이지 등에 추진제 및 각종 가스를 공급하는 통로역할을 하며, 발사준비가 완료된 후에는 발사체 이륙 전 또는 이륙과 동시에 발사체로부터 자동으로 분리된다. 각각의 체결장치 구성품으로는 발사체 이륙시 발생하는 고온의 화염으로부터 장치를 보호하는 PD(protective device), 접촉면에 기밀을 제공하고 추진제 누출을 방지는 MCP(multi-channel plate), 접촉면을 보호하기 위한 덮게, 각종 연결 배관의 전진과 후진을 위한 캐리지, 발사체와의 체결을 지지하는 그립 등이 있다. 발사 준비를 위해서 사전에 장치의 독립운용시험을 통해 각 구성품의 상태와 기능을 점검하고 장치의 작동성을 검증한다. 이후 발사체를 모사하는 기체 및 관제설비와 종합적으로 연계 시험과 모사시험을 수행하여 최종적으로 발사준비상태를 확인하게 된다. 이러한 자동체결장치의 운용 경험은 한국형발사체의 지상지원설비 개발에 활용할 수 있을 것이다.

  • PDF

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.

A Design and Implementation of Busbar Joint and Temperature Measurement System (부스바 접촉 상태 및 온도 감지 시스템 설계 및 구현)

  • Lee, Young-dong;Jeong, Sung-Hak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.379-385
    • /
    • 2017
  • In general, distribution board, panel board and motor control center can be installed over a wide area such as residence of group, building, schools, factories, ports, airports, water service and sewerage, substation and heavy industries that are used to supply converts the voltages extra high voltage into optimal voltage. There are electrical accidents due to rise of contact temperature, loose contact between busbar, deterioration of the contact resistance, over temperature of the busbars. In this paper, we designed and implemented the busbar joint and temperature measurement system, which can measure the joint resistance of busbar and loose connection between busbar using potentiometer and non-contact infrared sensor. The experimental results show that tightening the bolt and nut is fully engaged, resistance was decreased and maximum error range was 0.1mm. Also, the experimental result showed that the temperature at the contact area is increased from $27.3^{\circ}C$ to $69.3^{\circ}C$by the contact resistance.

베인 선단부의 탄성 유체 윤활

  • 정석훈;정재연
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.57-62
    • /
    • 1992
  • 탄성 유체 윤활은 윤활 표면의 탄성변형이 중요하게 다뤄지는 윤활의 형태로, 주로 로울러 베어링이나 기어와 같이 선접촉 집중하중을 받는 기계요소와 관련이 많다고 할 수 있다. 역사적으로 볼때 탄성 유체 윤활은 20 세기에 들어서 윤활 분야에서 획기적인 발전을 해온 것 중의 하나라고 볼 수 있으며, 윤활상태의 폭넓은 해석 뿐만아니라 전에는 고려하지 못했던 큰하중을 받는 기계요소들에 대한 윤활상태를 규명하는데 지대한 역할을 할 수 있음을 시사하고 있다. 한편 오래전 부터 실험적으로 탄성유체윤활을 해석함에 있어서 우선 고전적인 Reynolds 윤활 방정식에 윤활제의 유성특성인 고압하에서의 점성의 압력 의존성이 대단히 큰 피에조 점성효과를 고려하지 않으면 안된다. 나아가 등점도 조건하에서 재료의 탄성 변형을 함께 고려하여 연립 방정식의 형태로 구성해서 피에조 효과에서 발생하는 강한 비선형성을 갖는 대수 방정식의 해를 구하는 방안을 강구해야 한다.

  • PDF

A Study on the Application of Temporary Fence as a Ground Electrode (접지전극으로서의 가설울타리 활용방안에 관한 고찰)

  • Park, Sung-Yeol
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.127-128
    • /
    • 2023
  • 본 논문에서는 건설현장에 설치하는 가설울타리와 접지동봉을 매설하여 접지저항을 측정하였다. 접지저항을 측정한 결과 접지동봉은 10.8Ω이고, 가설울타리는 2.07 Ω이었으며, 이는 가설울타리가 접지전극으로 활용될 수 있음을 의미한다. 그러나, 가설울타리를 특별고압설비나 피뢰설비 등의 접지전극으로 활용할 때 가설울타리에 접지전류가 흐르게 되면 전위가 상승하고 접촉전압이나 보폭전압 등으로 인하여 감전사고가 발생할 수 있으므로, 가설울타리를 접지전극으로 활용하는 때는 신중해야 한다. 감전이나 화재 등의 위험이 없도록 안전조치를 한 상태에서 가설울타리를 접지전극으로 제한적으로 활용해야 할 것이다.

  • PDF

A Study on Development of Ultrasonic Transducer for High Temperature Ultrasonic Testing (고온 시험용 초음파 트랜스듀서 개발에 관한 연구)

  • 김기복;윤동진;이승석
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.432-437
    • /
    • 2002
  • 현재 비파괴 상태진단기술의 세계적인 연구동향은 비접촉식 시험기술, 실시간 광역기술, 고온 환경 하에서의 시험기술, 온라인 감시기술, 고감도, 고분해능, 소형화 및 무선통신기술 등을 개발하는 방향으로 연구가 활발히 진행되고 있다. 특히 고온 환경 하에서의 시험기술의 경우 철강공장 등에서 그 수요가 급증하고 있는데 반하여 국내의 경우 개발기술이 거의 전무하며 외국에서 전량 수입에 의존하고 있는 실정이다. 최근 여러 가지 다양한 복합재료와 공업용 재료들이 개발됨에 따라 이들 재료의 제작 공정이 복잡해질 뿐만 아니라 고온 및 고압의 공정조건이 요구되는 경우가 많다. 따라서 고온환경 하에서 재료의 특성을 비파괴적으로 검사할 수 있는 초음파 탐촉자가 요구된다고 하겠다. (중략)

  • PDF

Low Temperature Growth of Silicon Oxide Thin Film by In-direct Contacting Process with Photocatalytic TiO2 Layer on Fused Silica (광촉매 TiO2 층의 비접촉식 공정을 통한 저온 실리콘 산화박막 성장)

  • Ko, Cheon Kwang;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.236-241
    • /
    • 2008
  • The possibility of silicon oxidation through the aerial-diffusion of active oxygen species has been evaluated. The species originate from the surface of $TiO_2$ exposed by UV. Among process parameters such as UV intensity, substrate temperature and chamber pressure with oxygen, UV intensity was a major parameter to the influence on the oxide growth rate. When 1 kW high pressure Hg lamp was used as a UV source, the growth rate of silicon oxide was 8 times as faster as that of a 60 W BLB lamp. However, as the chamber pressure increased, the growth rate was declined due to the suppression of aerial diffusion of active oxygen species. According to the results, it could be confirmed that the aerial-diffusion of active oxygen species from UV-irradiated photocatalytic surface can be applied to a new method for preparing an ultra-thin silicon oxide at the range of relatively low temperature.

Improved Ultrastructural Preservation of Retinal Cells in Drosophila melanogaster (초고압동결장치를 이용한 초파리 레티나 세포의 향상된 미세구조)

  • Mun, Ji-Young;Park, Se-Jin;Han, Sung-Sik
    • Applied Microscopy
    • /
    • v.37 no.3
    • /
    • pp.175-183
    • /
    • 2007
  • The Drosophila retinal cell is widely used to study cell development and cell signaling processes. In the past decades, conventional chemical fixation had been used to study the structure of retinal cells in Droscphila. Rapid freezing methods are superior to chemical fixation methods due to their fixation speed. Some Drosophila tissues, such as the eyes, should not be freezed due to their surrounding cuticle layer. Therefore, in the case of the Drosophila retina, the benefits of high pressure freezing and freeze substitution (HPF-FS) had not been verified. In this study, a retinal cell from Drosophila melanogaster had been studied by using the HPF-FS method. Compared to chemical fixation, the preservation of the cytoplasm in the HPF-FS sample was improved on the whole. The HPF-FS cell membranes were smoother than that of chemical fixation. In addition, HPF-FS preserved the mitochondria structures very well. These results of the present study suggest that HPF-FS is superior to other fixation methods for the preservation of the retinal cell structure.