• Title/Summary/Keyword: 계측기

Search Result 1,697, Processing Time 0.03 seconds

Instrumentation for Performance Test of Turbo Compressor (터보 압축기 성능시험을 위한 계측기기 선정)

  • Park, Tae-Choon;Kang, Young-Seok;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.46-52
    • /
    • 2008
  • The instrumentation was studied in order to measure aerodynamic performance and efficiency of a compressor as a component of a 5MW-class gas turbine for power generation. In case of an axial compressor, the distributions of static pressure on a casing can be obtained by averaging at each stage and those of total pressure and temperature in the flow field of the compressor can be measured with a Kiel temperature probe. In case of a centrifugal compressor, the static pressures at the hub and the tip, respectively, of an impeller exit are considerably different, so the pressures need to be measured at both positions and thereafter averaged. The distributions of static pressures in a diffuser and a deswirler are measured at ten positions along five streamlines in one pitch. In addition the flow field can be measured in detail by 5-hole Pitot tube in order to analyze the flow characteristics of the core flow region and wake region and the rotor-stator interaction of the compressor.

  • PDF

Thermal Shrinkage Variation to the Measuring Method of Sensory PET Filament (감성소재 PET사의 계측방법에 따른 열 수축률 변화)

  • 김승진;박경순;유지수;홍성대;서봉기;김연숙;심승범;김소연;박미영
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.19-24
    • /
    • 2001
  • 본 연구에서는 국내 7개 기업에서 생산되고 있는 PET POY와 일본과 대만에서 생산되고 있는 PET POY 시료를 준비하여 이들 사의 열수축 특성을 hank 실험방법과 Toray FTA-500 계측기를 사용한 실험 data를 비교 분석하여 최근 도입되어 사용되고 있는 Toray FTA-500 열 수축률 측정계측기의 타당성을 조사하고자 한다. 본 연구를 위해 사용한 시료는 PET POY 85d/72f 그리고 120d/36f 그리고 120d/36f 2가지를 준비했으며 국내 합섬 maker 7개회사별로 각각 같은 굵기의 POY 사를 준비하였다. 그리고 국내 POY와 외국 소재로서 대만과 일본에서 생산되고 있는 소재의 열 수축률 특성치를 Toray FTA-500과 hank 방법을 비교 분석하므로서 감성의류 제조용 PET POY 사의 국내ㆍ외 소재의 차이점을 계측기계와 계측방법의 상이로 나누어 data화가 가능케 함으로서 감성의류소내 개발에 기초자료를 활용코자 한다.

  • PDF

Measurement of Thin Film Thickness of Patterned Samples Using Spectral Imaging Ellipsometry (분광결상 타원계측법을 이용한 패턴이 형성된 나노박막의 두께측정)

  • 제갈원;조용재;조현모;김현종;이윤우;김수현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.15-21
    • /
    • 2004
  • 반도체 제조산업과 나노, 바이오 산업의 비약적 발전에 따라 게이트 산화막(gate oxide)과 같이 반도체 제조공정에서 사용되는 유전체 박막(dielectric film)의 두께는 수 $\mu\textrm{m}$에서 수 nm 에 이르기까지 다양할 뿐 아니라 얇아지고 있으며, 또한 이러한 박막들이 다층으로 복잡하게 적층된 다층 박막의 응용이 높아지는 추세이다. 따라서, 반도체 및 광통신 소자, 발광소자, 바이오 칩 어레이 등과 같은 나노박막을 이용하는 산업에서는 박막의 두께 측정을 더욱 정확하고, 보다 빠르며 효율적으로 측정할 수 있는 박막 두께 측정용 계측기가 요구된다.(중략)

A wavefront analyzer for precise measurement of the visual acuity (시력 정밀 측정용 파면분석기)

  • 고동섭
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.72-73
    • /
    • 2003
  • 시력 진단장비로는 자각식 측정법인 시력표, 타각식 계측기로는 검영기와 자동굴절력측정기 등이 있으나 눈도 일반 광학계와 같이 공간적으로 불균일한 광학적 특성을 가지기 때문에 눈의 광학적 기능을 정확하게 진단하기 위해서는 광학수차의 공간 분포를 정밀하게 측정할 필요가 있다. 광학수차는 시력의 한계를 규정하고 안광학 기기의 설계에 있어서 중요한 요소이다. 눈의 광학수차를 측정하기 위한 파면분석기에는 공간분해굴절계, Tscherning 파면분석기, 광선추적파면분석기, 주사실틈굴절계, 그리고 Shack-Hartmann 파면분석기(SH 파면분석기) 등이 있으며, SH 파면분석기는 적응광학계에서도 유용하게 사용되고 있다. (중략)

  • PDF

A study on The Design of Embedded Network Module for Web-based Remote Verification and proofreading (웹기반 원격 검.교정 시스템을 위한 임베디드 네트워크 모듈 설계에 대한 연구)

  • Kim, Min-Geun;Lee, Sang-Hun;Lee, Hyuek-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.83-86
    • /
    • 2007
  • The necessity of the high speed exclusive use server that connect digital measure instrument flag to internet and CPU use rate of measure flag uses other imbedded operating system with many general servers to verification & proofreading system in remotion. This research is objective that embody high speed network module for Site-Based remote verification & proofreading system and through internet digital measure instrument flag to remote verification & proofreading, TCP/IP Offload Engine processing and improved that is Imbedded TCP/IP stack for high speed networking.

  • PDF

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

Application of Smart Transmitter Technology in Nuclear Engineering Measurements (지능형 송출기 기법의 원자력 계측에의 응용)

  • Kang, Hyun-Gook;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.403-412
    • /
    • 1993
  • By making use of the microprocessor technology, instrumentation system becomes intelligent. In this study a programmable smart transmitter is designed and applied to the nuclear engineering measurements. In order to apply the smart transmitter technology to nuclear engineering measurements, the digital time delay compensation function and water level change detection function are developed and applied in this work. The time compensation function compensates effectively the time delay of the measured signal, but it is found that the characteristics of the compensation function should be considered through its application. It is also found that the water level change detection function reduces the detection time to about 7 seconds by the signal processing which has the time constant of over 250 seconds and which has the heavy noise.

  • PDF

A study on The Design of Embedded Network Module for Web-based Remote Verification and proofreading (웹기반 원격 검.교정 시스템을 위한 임베디드 네트워크 모듈 설계에 대한 연구)

  • Kim, Min-Geun;Lee, Sang-Hun;Lee, Hyuek-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1077-1082
    • /
    • 2007
  • The necessity of the high speed exclusive use server that connect digital measure instrument flag to internet and CPU use rate of measure flag uses other imbedded operating system with many general servers to verification & proofreading system in remotion. This research is objective that embody high speed network module for Site-Based remote verification & proofreading system and through internet digital measure instrument flag to remote verification & proofreading, TCP/IP Offload Engine processing and improved that is Imbedded TCP/IP stack for high speed networking.

The Development of Electronic Transformer(CT/PT) for Intelligent GIS Based on IEC 60044 (IEC 60044 기반 Intelligent GIS용 전자식 변성기 개발)

  • Kim, M.S.;Jung, J.R.;Kim, J.B.;Song, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2262-2264
    • /
    • 2005
  • 지금까지 변전소나 개폐소에서 전류, 전압을 계측하는 수단으로서 주로 철심과 권선으로 구성되어진 변류기(CT), 계기용 변압기(PT, PD)가 사용되어져 왔다. 최근, 2차측의 계측기나 보호 Relay의 Digital화가 진전되어 또한 이것을 Digital Network으로 총합한 Intelligent 변전소의 구축이 검토되어지고 있으며, Digital Network에 대응한 변성기 관련규격인 IEC 60044가 근래 제정되어짐에 따라 이에 적합한 전자식 변성기가 요구되어지고 있다. 상기와 같은 요구로 인해 당사에서는 IEC 60044를 기반으로 한 전자식변성기 Layout을 구성하였으며, CT는 검출부에 Rogowski Coil을 적용하며 그 후단에 적분기를 설치하였으며, VD는 검출부에 중간 전극을 이용해서 분압하는 방식인 Capacitive Voltage Divider를 사용하고 증폭기를 삽입하여, 각각 요구되는 전압 신호를 얻었다. 이러한 신형 CT/VD의 적용으로 종래의 CT/PT가 차지하는 공간이 필요없게 되어 컴팩트한 GIS의 구조가 가능하게 되어 있다.

  • PDF

A Study on the Verification and Improvement to Locate and Determine the Radioactive Contamination Using a Whole Body Counter (전신계측기를 이용한 원전종사자 방사성오염 위치확인과 내부방사능 측정개선에 관한 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Whole body counters (WBCs) are used to monitor radiation workers for internal contamination of radionuclides at domestic nuclear power plants (NPPs). A WBC is a scintillation detector using sodium iodide (NaI) and provides the identification of inhaled radionuclide and the measurement of its internal radioactivity in a short time. However, it is often possible to estimate external contamination as internal contamination due to radionuclides attached to the skin of radiation workers and this leads to an excessively conservative estimation of radioactive contamination. In this study, several experiments using a WBC and the Korean humanoid phantom were performed to suggest the more systematic method of discrimination between external and internal contamination. Furthermore, a WBC geometry experiment was conducted to suggest the optimal WBC geometry in consideration of deposited areas inside the body for dominant radionuclides at NPPs. The procedure of measurement and estimation of internal radioactivity for radiation workers at NPPs was improved on the basis of experimental results. Thus, it is expected to prevent from estimating internal exposure dose conservatively owing to the application of accurate whole body counting program to NPPs.