• Title/Summary/Keyword: 계산기관

Search Result 477, Processing Time 0.029 seconds

A Study on the Eco-Cultural Assessment Indicator for Buddhist Temple Forest - Focused on Mt. Jogye Songgwang-sa Temple - (사찰림의 생태문화적 평가지표에 관한 연구 - 조계산 송광사를 중심으로 -)

  • Jang, Young-Whan;Koo, Bon-Hak
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.74-88
    • /
    • 2019
  • This study developed the Assessment Indicator evaluating eco-cultural value of temple forest in Korea and applied the developed Assessment Indicator to Songgwang-sa(also known as Seungbo-sachal), one of the Three Jewels Temple. Literature reviews and the draft of Assessment Indicator were drawn from brainstorming(including 2 forest therapy experts, 1 Buddhist monk expert, 1 landscape architect, 1 forest expert, and 6 researchers). After that, the Assessment Indicator drawn from the group of experts(the 1st in-depth interview: 32 people, the 2nd in-depth interview: 30 people) was verified and revised. The final Assessment Indicator, which was composed of 4 parts and 20 items, was developed. The results are as follows. The eco-cultural Assessment Indicator of temple forest was composed of 4 parts, which were Historical Cultural value, Ecological value, Recreatory Visitational value, and Educational Useful value, and 20 items and each item had 5 points. Historical Cultural value had 5 items and its total points were 25. Ecological value had 5 items and had total 25 points. Recreatory Visitational value had 6 items, 30 total points. Educational Useful value had 4 items, 20 total points. The total points of the eco-cultural Assessment Indicator were 100 points. As a result of applying the developed Assessment Indicator to the target place, Songgwang-sa in Mt. Jogye, Historical Cultural value of temple forest was calculated as 23 points(out of 25). Ecological value was 21 point(out of 25), Recreatory Visitational value, 22 points(out of 30), and Educational Useful value, 16 points(out of 20). The total points were 82(out of 100). Consequently, this study is meaningful based on the following 5 aspects. Firstly, this study challenged the development of the eco-cultural Assessment Indicator of temple forest for the first time. It is significant because the developed Assessment Indicator can be a useful resource for the eco-cultural value of temple forest. Secondly, the result showed that Educational Useful value and Recreatory Visitational value of forest temple were very low. Therefore, the supports for leisure, tour, education, and use of temple forest are needed from Korea Forest Service, Ministry of Environment, Cultural Heritage Administration and other government agencies since they acknowledge the temple forest as the best customers in Korea. Thirdly, the excellence or for eco-cultural value of temple forest needs to be extended in a national level. It is possible to make a Korean National Bran(e.g., the Therapy at the Temple) by blending temple stay, which is only in temples, and therapy, and is also possible to be a global tour industry. Fourthly, this study suggested legal definition about the necessary of legal definition for temple forest because there is no legal definition on temple forest in the current situation. When the definition of temple forest is legally arranaged, it would be a foundation for conserving eco-cultural value of temple forest, for organizing exclusively responsible departments in governmental institutions, and further for registering temple forest as World Natural Heritage. Lastly, the developed eco-cultural Assessment Indicators of temple forest from this study would be applied to "the 7 Sansa, Buddhist Mountain Monasteries in Korea(Sansa)" and the characteristics of each 7 temple are drawn. This study would be a basic data for temples' management and use with the eco-cultural Assessment Indicator of temple forest.

A Study on Design Education Re-engineering by Multi-disciplinary Approach (다학제적 접근을 통한 대학디자인 교육혁신 프로그램 연구)

  • Lee, Soon-Jong;Kim, Jong-Won;Chu, Wu-Jin;Chae, Sung-Zin;Yoon, Su-Hyun
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.299-314
    • /
    • 2007
  • For the past 20 years, the growth and development of university-design-educational institutes contributed to the industrial development of our country. Due to the technological fluctuation and changes in the industrial structure in the latter half of the 20th century, the enterprise is demanding professionally-oriented design manpower. The principle which appears from instances of the advanced nations is to accommodate the demands in social changes and apply them to educational design programs. In order to respond promptly to the industrial demand especially, the advanced nations adopted "multidisciplinary design education programs" to lead innovation in the area of design globally. The objective of the research consequently is to suggest an educational system and a program through which the designer can be educated to obtain complex knowledge and the technique demanded by the industry and enterprise. Nowadays in order to adapt to a new business environment, designers specially should have both the knowledge and techniques in engineering and business administration. We suggest that the IPDI, a multidisciplinary design educational system and program is made up of the coordinated operation of major classes, on-the-job training connection, educational system for research base creation, renovation design development program for the application and the synthesis of alternative proposals about the training facility joint ownership by connecting with the education of design, business administration and engineering.

  • PDF

Resting Energy Expenditure in Patients with Lung Cancer (폐암 환자의 안정시 에너지 소비)

  • Lee, Jae-Lyun;Kim, Ki-Beom;Lee, Hak-Jun;Jung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1019-1029
    • /
    • 1997
  • Background : Elevation of resting energy expenditure(REE) in patients with lung cancer has been described in earlier studies and may contribute to cancer cachexia, but limited information is available regarding the prevalence and determinants of the increased REE. The aim of this study was to assess the prevalence and contributing factors of a hypermetabolic state in newly detected patients with lung cancer and to assess the energy balance in order to improve our knowledge about weight loss in patients with lung cancer. Method : Thirty one consecutive, newly detected patients with lung cancer and 20 control patients with benign lung diseases were included in this study. Resting energy expenditure(REE) was measured by indirect calorimetry using ventilated hood system and predicted REE was calculated by the Harris-Benedict formular. Results : The energy balance in newly detected lung cancer patients was disturbed in a high proportion of patients, and hypermetabolic state occurred in 61% of the patients. Tumor volume, cancer type, location, stage, the presence of atelectasis or infiltration, pulmonary function, or smoking behavior were not associated with increase in REE. But patients with distant metastasis had significantly higher REE comparing with patients without metastasis. Thirty nine percents of the patients with lung cancer had substantial loss of more than 10% of their pre-illness weight. Weight losing patients with lung cancer were not accompanied by an increase in REE. Conclusion : We concluded that the REE was elevated in a higher proportion of patients with lung cancer and distant metastasis was found to be contributing factor to the elevated REE.

  • PDF

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

The Study on the Use of a Cylindrical Ionization Chamber for the Calibration of a 6 MeV Electron Beam (6 MeV 전자 빔의 교정에 원통형 이온함의 사용에 관한 연구)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Choi, Jin-Ho;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.317-323
    • /
    • 2009
  • The standard dosimetry systems based on an absorbed dose to water recommend to use a planeparallel chamber for the calibration of such a low-megavoltage electron beam as a nominal energy of 6 MeV. For this energy ranges of an electron beam a cylindrical chamber should not be used for the routinely regular beam calibration, but the feasibility of the temporary use of a cylindrical chamber was studied to give temporary solutions for special situations users meet. The PTW30013 chambers and the electron beam quality of $R_{50}=2.25\;g/cm^2$ were selected for this study. 10 PTW30013 chambers, a cylindrical type of chamber, were calibrated in KFDA, the secondary standards dosimetry laboratories, and given the absorbed dose-to-water calibration factors, respectively. A "temporary" $k_{Q,Q_0}$ for each chamber were calculated using the absorbed dose determined by a cross-calibrated planeparallel chamber, with the result of an average 0.9352 for 10 chambers. This value for PTW30013 chamber was used to determine an absorbed dose to water at the reference depth. The absorbed doses determined by PTW30013 chambers were in an agreement within 2% with that by ROOS chamber. In a certain situation where a cylindrical chamber be used instead of a planeparellel chamber, the value of 0.9352 might be useful to determine an absorbed dose to water in the same beam quality of electron beam as this study.

  • PDF

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

A Study on the Factors that Determine the Initial Success of Start-Up (스타트업의 초기 성공을 결정하는 요인에 관한 연구)

  • Lee, Hyun Ho;Yun, Hwangbo;Gong, Chang-Hoon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • The purpose of this study is to find out which factors determine the success of start-up in the initial market and what are the most important determinants. For the empirical analysis, the questionnaire related to the analysis of success factors for start-up success was designed according to the quantitative analysis (AHP technique). First, we selected 8 representative success factors for successful start-up in the initial market. In order to determine the degree of priority among these factors, we surveyed 12 entrepreneurs who are interested in entrepreneurship, universities, research institutes, and public officials. As a result of the empirical analysis, 51% of the funds in the tier 1 were ranked as the top priority to determine success factors. Followed by research and development (32.5%), management (8.7%) and marketing (7.8%). In particular, when each of the four items is calculated as 100 according to the result of the tier 1, and the tier 2 is converted, the foreign investment is analyzed as 43.7%. It was followed by 15.14% of R & D facilities, 14.07% of ideas, 8.7% of managerial ability, 7.29% of domestic investment, 5.85% of buyer feedback, 3.3% of development strategy and 1.95% of marketing strategy. Among the eight success factors, overseas investment items showed the closest preference to half, and it was the most important variable that determines the success or failure of market entry. The implication of this study is that many start-ups in Korea expect to receive investment and support from overseas accelerators. This means that overseas investment itself has been recognized as a start-up that makes services and products that can be used in the global market. A high preference for attracting foreign investment is due to the fact that the amount of investment is larger than that of Korea and that it can flexibly cope with the pressure on the performance compared to domestic investors. In this study, it was meaningful that we could confirm this fact through questionnaires of start-up experts. In future research, we need to find a viable alternative through studying how to provide start-up to foreign direct investment at the national level.

  • PDF

Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy (폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가)

  • Jang, Hyeong Jun;Lee, Yeong Gyu;Kim, Yeong Jae;Park, Yeong Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • Purpose : This study will evaluate the clinical utility by applying clinical schematic that uses monoenergy or dual energy as according to the location of tumors to the stereotactic radiotherapy to compare the change in actual dose given to the real tumor and the dose that locates adjacent to the tumor. Materials and Methods : CT images from a total of 10 patients were obtained and the clinical planning were planned based on the volumetric modulated arc therapy on monoenergy and dual energy. To analyze the change factor in the tumor, Comformity Index(CI) and Homogeneity Index(HI) and maximum dose quantity were each calculated and comparing the dose distribution on normal tissues, $V_{10}$ and $V_5$, first ~ fourth ribs closest to the tumor ($1^{st}{\sim}4^{th}$ Rib), Spinal Cord, Esophagus and Trachea were selected. Also, in order to confirm the accuracy on which the planned dose distribution is really measured, the 2-dimensional ion chamber array was used to measure the dose distribution. Results : As of the tumor factor, CI and HI showed a number close to 1 when the two energies were used. As of the maximum dose, the front chest wall showed 2% and the dorsal tumor showed equivalent value. As of normal tissue, the front chest wall tumors were reduced by 4%, 5% when both energies were used in the adjacent rib and as of trachea, reduced by 11%, 17%. As of the dose in the lung, as of $V_{10}$, it reduced by 1.5%, $V_5$ by 1%. As of the rear chest wall, when both energies were used, the ribs adjacent to the tumors showed 6%, 1%, 4%, 12% reduction, and in the lung dose distribution, $V_{10}$ reduced by 3%, and $V_5$ reduced by 3.1%. The dose measurement in all energies were in accordance to the results of Gamma Index 3mm/3%. Conclusion : It is considered that rather than using monoenergy, utilizing double energy in the clinical setting can be more effectively applied to the superficial tumors.

  • PDF

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF

The Calculation Method of Cell Count for the Bloom-forming (Green tide) Cyanobacterium using Correlation between Colony Area and Cell Number in Korea (군체 크기와 세포수 상관관계를 이용한 녹조 유발 남조류의 세포수 산정 방법)

  • You, Kyung-A;Song, Mi-Ae;Byeon, Myeong-Seop;Lee, Hae-Jin;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.4
    • /
    • pp.350-357
    • /
    • 2014
  • Harmful Algal Bloom Alert System (HABAS) for drinking water supply is require to fast and accurate count as system monitoring of cyanobacterium occurrence and inducing a response action. We measured correlation between colony size and cell number including genus Anabaena, Aphanizomenon, Microcystis, Oscillatoria which are targeted at HABAS, deducted from standard formula, and suggested calculation method from colony size to the number of cell. We collected cyanobacteria samples at Han River (Paldang reservoir), Nakdong River (Dalseong weir, Changnyeonghaman weir) and Geum River (Gobok reservoir) from August to October, 2013. Also, we studied correlation between colony size and cell number, and calculated regression equation. As a result of correlation of harmful cyanobacteria by genus, Anabaena spp. and Aphanizomenon spp. having trichome showed high correlation coefficients more than 0.93 and Microcystis spp. having colony showed correlation coefficient of 0.76. As a result of correlation of harmful cyanobacteria by species, Anabaena crassa, Aphanizomenon flos-aquae, A. issatschenkoi, Oscillatoria curviceps, O. mougeotii having trichome showed high correlation coefficients from 0.89 to 0.96, and Microcystis aeruginosa, M. wessenbergii, M. viridis having colony showed correlation coefficients from 0.76 to 0.88. Compared with other genus Microcystis relatively showed low correlation because even species and colony size are the same, cell density and cell size are different from Microcystis strains. In this study, using calculated regression might be fast and simple method of cell counting. From now on, we need to secure additional samples, and make a decision to study about other species.