• 제목/요약/키워드: 경량충격음

검색결과 46건 처리시간 0.026초

공동주택 경량바닥충격음 측정불확도 추정에 관한 연구 (A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors)

  • 고종철;이종인;김현배;이철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

경량충격음 차단성능 실험실 측정방법 고찰 (A Survey on the Laboratory Measurements of Impact Sound Insulation of Floors)

  • 송민정;장길수;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.976-979
    • /
    • 2004
  • The KS of 'Laboratory Measurement of Impact Sound Insulation of Floors' is not established yet. To establish this KS, present conditions of domestic laboratory test facilities for measuring impact sound insulation of floors in laboratory and current researches were reviewed As a result the outline of 'Laboratory Measurement of Impact Sound Insulation of Floors' is suggested.

  • PDF

건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 - (Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure -)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

건식 이중바닥구조의 중량충격음 저감성능 평가 (Evaluation for The Heavy-weight Impact Sound Reduction Performance of Dry Double-Floor System)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.280-285
    • /
    • 2012
  • The 1st assessment (performance test) was applied to assure the floor impact sound performance for developing the dry double- floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in substructure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5dB. Based on this result, the 2nd assessment (performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry doublefloor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPE-11 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPE-11 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

  • PDF

경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석 (Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source)

  • 진필화;김흥식;김도형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF

소음 차단 성능 향상을 위한 부틸 탄성체 배합 및 진동제어 시스템 디자인 연구 (Study on the Design of Butyl Rubber Compound and Noise Reduction System for Sound Insulation)

  • 김원택;정경호
    • Elastomers and Composites
    • /
    • 제49권2호
    • /
    • pp.95-102
    • /
    • 2014
  • 최근 공동주택의 층간 소음으로 인하여 사회적 문제가 크게 대두되고 있다. 본 연구에서는 소음 차단 성능을 향상시키기 위해 바닥 진동 제어 시스템에 적용되어질 방진고무를 제조하였다. 다양한 유형의 고무 중 우수한 노화특성, 낮은 반발탄성 및 높은 댐핑특성의 성질은 갖는 부틸 고무를 방진고무의 원료 고무로 선정하였다. 그리고 부틸 컴파운드에 첨가되는 카본블랙의 유형과 함량에 따른 방진고무의 물성을 확인하였다. 표면적이 큰 카본블랙을 사용하거나 함량이 증가할수록 고무와 카본블랙간의 결합고무의 함량이 증가하여 높은 기계적 물성, 낮은 반발탄성과 높은 댐핑특성을 나타내었다. 연구 결과를 토대로 최적의 카본블랙 종류와 함량을 결정하고 방진고무를 제조한 뒤 바닥진동제어 시스템에 적용하였다. 바닥충격음을 측정한 결과 경량충격음 40 dB, 중량충격음 43 dB을 나타내어 소음차단 성능이 우수한 것을 확인할 수 있었다.

신축공동주택의 상하층간 소음 및 진동전달 특성과 층간소음 차단성능에 관한 연구 (Study on the Characteristic of Floor Sound and Vibration Transfer and the Blocking Function of Floor Sound for Newly Built Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제24권2호
    • /
    • pp.97-104
    • /
    • 2013
  • This study involves 2 newly built apartment houses which are A with 23 floors as 150 mm slab width and B with 16 floors as 180 mm slab width. The impact was added by tapping and bang machine at the middle floor level of these 2 apartments and the test was arranged in terms of the characteristic of vibration and sound level which transferred to upper or down floors. As a result, impact floor shows the highest value in terms of both sound and vibration level and followed was at down floor of the Impact floor. Also, blocking function for the lightweight and heavyweight floor impact sound level was tested for each room of the apartment A and B including living room, main room, room 1 and 2. As a result, sound blocking function of B apartment was better than that of A and the function was getting worse when the room size is getting smaller.

바닥충격음 완충재의 동적특성과 소음저감 성능 비교 (Comparison Between the Dynamic Properties and Noise Isolation Performances for a Floor Impact Isolation Pad)

  • 양수영;이동훈;홍병국;송화영;이주원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.275-278
    • /
    • 2005
  • In this study, the dynamic properties of a floor impact sound isolation pad expressed in terms of the natural frequency, the dynamic stiffness per unit area and the loss factor are measured by the resonant method. By using the measured dynamic properties, the vibration transmissibility diagram is obtained for each isolation pad, which is compared with the values tested by the impact sound sources at the room in an apartment. From the comparative results, it is found that the noise reduction Performances. of isolation pads are closely connected with the natural frequency and the dynamic stiffness per unit area.

  • PDF

경량 바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • 장길수;정광용;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.950-955
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF