• Title/Summary/Keyword: 경량성

Search Result 1,716, Processing Time 0.038 seconds

The ages and stages questionnaire: screening for developmental delay in the setting of a pediatric outpatient clinic (ASQ :소아과외래에서의 발달지연 선별검사)

  • Kim, Eun Young;Sung, In Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1061-1066
    • /
    • 2007
  • Purpose : Early identification of developmental disabilities allows intervention at the earliest possible point to improve the developmental potential. The Ages and Stages Questionnaire (ASQ), a parent- completed questionnaire, can be used as a substitute for formal screening tests. The purpose of this study was to evaluate the validity of the Korean version of the ASQ (K-ASQ) as a screening tool for detecting developmental delay of young Korean children in the setting of a busy pediatric outpatient clinic. Methods : Parents completed the K-ASQ in the waiting room of the pediatric outpatient clinic of St. Mary's Hospital, Catholic University Medical College. Out of 150 completed the ASQ, 67 who were born term and had no previous diagnosis of developmental delay, congenital anomalies, or neurological abnormalities were enrolled. The cut-off values of less than 2 standard deviations (SD) below the mean for the ASQ were used to define a "fail", and children who failed in one or more domains tested were classified as "screen-positive". Diagnosis of developmental delay was made when the developmental indices fell below -1 SD of the Bayley Scales of Infant Development-II. Results : (1) The mean age of children was $16.4{\pm}7.4$ months. Ten children (14.9%) were small-for- gestational age infants. The mean birth weight and gestational age were $3.1{\pm}0.6kg$ and $38.8{\pm}1.4$ weeks. Nine children (13.4%) were twins and 33 (49.0%) were male. The mean maternal education in years was $13.6{\pm}2.4$, and 31.3% had full-time jobs. The time for completing the ASQ was $10.2{\pm}3.0$ minutes. (2) Seventeen children (25.4%) were classified as screen-positive, four of them were delayed in development. Among eight children diagnosed with developmental delay, four were screen-positive and the other four were screen-negative by the ASQ. (3) The test characteristics of the ASQ were as follows: sensitivity (50.0%); specificity (78.0%); positive predictive value (23.5%); negative predictive value (92.0%). Conclusion : The high negative predictive value of the K-ASQ supports its use as a screening tool for developmental delay in the setting of a pediatric outpatient clinic.

Neonatal hearing screening in a neonatal intensive care unit using distortion product otoacoustic emissions (변조 이음향방사(DPOAE)를 이용한 고위험군 신생아 청각선별검사)

  • Kim, Do Young;Kim, Sung Shin;Kim, Chang Hwi;Kim, Shi Chan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.5
    • /
    • pp.507-512
    • /
    • 2006
  • Purpose : Early detection and intervention of hearing impairment is believed to improve speech and language development and behavior of children. The aim of this preliminary study was to determine the prevalence of hearing impairments, and to identify the association of risk factors relating to refer response in high risk neonates who were screened using distortion product otoacoustic emissions (DPOAE). Methods : The subjects included 871 neonates who were admitted to the neonatal intensive care unit of the Pediatric Department in Soonchunhyang University Bucheon Hospital from May, 2001 to December, 2004. They were screened using DPOAE. Based on DPOAE, we divided the neonates in two groups : 'Pass' and 'Refer'. The differences in risk factors between the pass group and the refer group were analyzed. Results : The incidence of the refer group was 12.1 percent(106 out of 871). The bilateral refer rate was 5.4 percent(47 out of 871). And the unilateral refer rate was 6.7 percent(59 out of 871). Gender, birth place, family history of hearing loss, small/large for gestational age, obstetrical factor, hyperbilirubinemia and use of gentamicin were not statistically related to the refer rate. Statistically related to refer rate were birth weight, resuscitated neonates, Apgar score, craniofacial anomaly, mechanical ventilator application, sepsis, using of vancomycin(P<0.05). The prevalence of hearing impairment (${\geq}60dB$) in this study was 2 percent(18 out of 871). Conclusion : This study showed a higher prevalence of hearing impairment in high-risk neonates. Thus neonatal hearing screening should be carried out in high-risk neonates.

Clinical Features of Cricopharyngeal Incoordination in Newborns and Infants (신생아 및 영아기 윤상인두 협조불능의 임상적 고찰)

  • Han, Young-Mi;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.116-121
    • /
    • 2008
  • Purpose: Cricopharyngeal incoordination is a rare cause of swallowing difficulties in newborns and infants; it is characterized by delayed pharyngeal contractions related to cricopharyngeal relaxation. Dysphagia and repeated aspiration are common findings despite normal sucking. We conducted this study to assess the clinical features of cricopharyngeal incoordination in newborns and infants. Methods: An analysis of the clinical data from 17 patients with cricopharyngeal incoordination who were admitted to the Department of Pediatrics, Pusan National University Hospital, between 2000 and 2006 was conducted retrospectively. The diagnosis of cricopharyngeal incoordination was established by the clinical characteristics and the videofluoroscopic swallowing studies. Results: The male to female ratio was 1:1.1 (males 8, females 9) the age range 1 to 60 days. The body weight of 11 patients (64.7%) was less than the $10^{th}$ percentile at diagnosis. Six patients (35.3%) were born prematurely. The associated anomalies or diseases were chromosomal anomaly (2 cases), congenital heart disease (3 cases), and laryngomalacia, hypoxic brain damage or neonatal seizures (1 case each). The chief complaints of patients were recurrent aspiration pneumonia (10 cases), feeding difficulty (9 cases), dyspnea (4 cases), and chocking (4 cases). The severity of aspiration on the videoesophagogram or esophagogram was mild in 12 cases. The correlation between the severity of aspiration and the duration of tube feeding after the diagnosis was significant (p<0.05). Conclusion: Cricopharyngeal incoordination should be considered in the differential diagnosis of newborns and infants, without known risk factors associated with swallowing dysfunction, when they present with unexplained respiratory problems. Although the prognosis of cricopharyngeal incoordination is good, early diagnosis and tube feeding are recommended to prevent the complications associated with this disorder.

  • PDF

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A Study on the Development of Ultra-precision Small Angle Spindle for Curved Processing of Special Shape Pocket in the Fourth Industrial Revolution of Machine Tools (공작기계의 4차 산업혁명에서 특수한 형상 포켓 곡면가공을 위한 초정밀 소형 앵글 스핀들 개발에 관한 연구)

  • Lee Ji Woong
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.119-126
    • /
    • 2023
  • Today, in order to improve fuel efficiency and dynamic behavior of automobiles, an era of light weight and simplification of automobile parts is being formed. In order to simplify and design and manufacture the shape of the product, various components are integrated. For example, in order to commercialize three products into one product, product processing is occurring to a very narrow area. In the case of existing parts, precision die casting or casting production is used for processing convenience, and the multi-piece method requires a lot of processes and reduces the precision and strength of the parts. It is very advantageous to manufacture integrally to simplify the processing air and secure the strength of the parts, but if a deep and narrow pocket part needs to be processed, it cannot be processed with the equipment's own spindle. To solve a problem, research on cutting processing is being actively conducted, and multi-axis composite processing technology not only solves this problem. It has many advantages, such as being able to cut into composite shapes that have been difficult to flexibly cut through various processes with one machine tool so far. However, the reality is that expensive equipment increases manufacturing costs and lacks engineers who can operate the machine. In the five-axis cutting processing machine, when producing products with deep and narrow sections, the cycle time increases in product production due to the indirectness of tools, and many problems occur in processing. Therefore, dedicated machine tools and multi-axis composite machines should be used. Alternatively, an angle spindle may be used as a special tool capable of multi-axis composite machining of five or more axes in a three-axis machining center. Various and continuous studies are needed in areas such as processing vibration absorption, low heat generation and operational stability, excellent dimensional stability, and strength securing by using the angle spindle.

Perinatal Outcomes of In Vitro Fertilized Twins in Women of Advanced Age (고연령 산모에서 체외 수정 시술로 태어난 쌍생아의 임상 양상)

  • Chung, In-Hyuk;Kim, Sung-Woo;Jo, Heui-Seung;Lee, Kyu-Hyung
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.197-203
    • /
    • 2011
  • Purpose: The purpose of this study is to compare perinatal outcomes between in vitro fertilization (IVF) twins and naturally conceived twins born to women aged 35 years or older and to provide basic information for taking care of IVF twins born to women aged 35 years or older. Methods: We reviewed the records of perinatal and neonatal outcomes in 288 IVF twins and 220 naturally conceived twins born to women aged 35 years or older between January 2001 and December 2010 at CHA Bundang Medical Center. Results: No difference was observed in the maternal ages of mothers giving birth to IVF twins and those giving birth to naturally conceived twins. Gestational ages and birth weights of IVF twins were not different from those of naturally conceived twins. Various perinatal outcomes, including gestational diabetes mellitus, pregnancy-induced hypertension, placenta previa, premature amniotic membrane rupture, and need for a Cesarean section did not differ between the 2 groups. However, the 1-min and 5-min Apgar scores (P=0.019 and P=0.045, respectively) were different between the 2 groups. The incidence of early-onset sepsis was lower in the IVF twins than in the naturally conceived twins (P=0.02). However, the 2 groups did not show any difference in the incidence of respiratory distress syndrome, bronchopulmonary dysplasia, patent ductus arteriosus, necrotizing enterocolitis, intraventricular hemorrhage, and other congenital anomalies. Conclusion: The perinatal outcomes in IVF twins born to women aged 35 years or older were not significantly different from those of naturally conceived twins.

Studies on Engneering Properties of Coal Ash Obtained as Industrial Wastes (산업폐기물(産業廢棄物)로 발생(發生)되는 석탄회(石炭灰)의 토질력학적(土質力學的) 특성(特性)에 관한 연구(硏究))

  • Chun, Byung Sik;Koh, Yong Il;Oh, Min Yeoul;Kwon, Hyung Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.115-123
    • /
    • 1990
  • The purpose of this study was to examine the uses of coal ash as a type of construction material. The methods of examination were chemical anlysis, soil laboratory test and the soil vibration test. Materials used were coal ash obtained as a by-product from 5 thermal power plants in Yongdong, Yongwol, Sochon(anthracite coal) and in Samchonpo and Honam (bituminous coal). Over 70% of the coal ash consisted of silica and alumina. The fly ash grain size showed a uniform distribution from fine-sand to silt, and that of the bottom ash showed from sand to gravel. The specific gravity and density of the coal ash were low. The long term strength increased gradually due to the self-setting property resulting from pozzolanic activity. The shear strength was higher than that of general soil. Cohesion and optimum moisture content of anthracite coal ash were higher than bituminous coal ash, whereas the maximum dry density was higher in bituminous coal ash. The coal ash dynamic Young's modulous curve range was similar to that of general soil. Of the results from the soil vibration test by car-running, the size relative acceleration level in the ash pond was higher than that of natural ground, but the damping ratio was lower than that of natural ground near the ash pond. The coal ash has more advantageous engineering properties than general soil with particles of the same size. For example, the California Bearing Ratio of the bottom ash at both Yongdong and Yongwol was 77~137%. Therefore we expect that if further study is done, coal ash can be used as a construction material when reclaiming seashore, construction embankments, road construction, making right-weight aggregate, or as a general construction material.

  • PDF

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Pulmonary Hypertension Secondary to Bronchopulmonary Dysplasia in Very Low Birth Weight Infants (<1,500 g) (기관지 폐 이형성증을 가진 극소 저체중 출생아에서 폐고혈압증)

  • Yoo, Hye-Soo;Kim, Myo-Jing;Kang, Ji-Man;Lee, Cha-Gon;Kim, Jin-Kyu;Ahn, So-Yoon;Kim, Eun-Sun;Huh, June;Chang, Yun-Sil;Kang, I-Seok;Park, Won-Soon;Lee, Heung-Jae
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.96-103
    • /
    • 2011
  • Purpose: Although infants with bronchopulmonary dysplasia (BPD) are at risk of developing secondary pulmonary hypertension (PH), which is associated with significant morbidity and mortality, little has been reported about the incidence, clinical course and prognosis of PH secondary to BPD in premature infants. This study was done to investigate the incidence, risk factors, clinical course, and the ultimate prognosis of PH developed secondary to BPD in very low birth weight infants (<1,500 g). Methods: Medical records of very low birth weight infant (VLBWI) admitted to Samsung Medical Center NICU from January 2000 to July 2007 were reviewed retrospectively. BPD was defined by Jobe's classification. The diagnosis of pulmonary hypertension was established as velocity of tricuspid valve regurgitation (TR) ${\geq}$3 m/s and a flattening of the intraventricular septum by conducting Doppler echocardiography. Results: The incidence of pulmonary hypertension was 6% in VLBWI with BPD and it developed in moderate to severe BPD. The diagnosis of pulmonary hypertension was made on postnatal 133 days (range 40-224 days) and the risk factors related to developing pulmonary hypertension were severe BPD, small for gestational age and outborn infants. The mortality rate was 57% and especially higher in severe BPD (70%). The time to recovery spent 3 months (range 1-10 months) in survived patients. Conclusion: Based on the results of this research, pulmonary hypertension secondary to BPD in VLBWI related to severity of BPD and had a poor prognosis. We expect that regular long-term echocardiography may be helpful in treating reversible in VLBWI with moderate to severe BPD.

Development of the paper bagging machine for grapes (휴대용 포도자동결속기 개발연구)

  • Park, K.H.;Lee, Y.C.;Moon, B.W.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.11 no.1
    • /
    • pp.79-94
    • /
    • 2009
  • The research project was conducted to develop a paper bagging machine for grape. This technology was aimed to highly reduce a labor for paper bagging in grape and bakery. In agriculture labor and farm population has rapidly decreased since 1980 in Korea so there was so limit in labor. In particular there is highly population in women and old age at rural area and thus labor cost is so high. Therefore a labor saving technology in agricultural sector might be needed to be replaced these old age with mechanical and labor saving tool in agriculture. The following was summarized of the research results for development of a paper bagging machine for grape. 1. Development of a new paper bagging machine for grape - This machine was designed by CATIA VI2/AUTO CAD2000 programme. - A paper bagging machine was mechanically binded a paper bag of grape which should be light and small size. This machine would be designed for women and old age with convenience during bagging work at the field site. - This machine was manufactured with total weight of less than 350g. - An overage bagging operation was more than 99% at the actual field process. - A paper bagging machine was designed with cartridge type which would be easily operated between rows and grape branches under field condition. - The type of cartridge pin was designed as a C-ring type with the length of 500mm which was good for bagging both grape and bakery. - In particular this machine was developed to easily operated among vines of the grape trees. 2. Field trials of a paper bagging machine in grape - There was high in grape quality as compared to the untreated control at the application of paper bagging machine. - The efficiency of paper bagging machine was 102% which was alternative tool for the conventional. - The roll pin of paper bagging machine was good with 5.3cm in terms of bagging precision. - There was no in grape quality between the paper bagging machine and the conventional method. - Disease infection and grape break was not in difference both treatments.