• Title/Summary/Keyword: 격자 영사

Search Result 19, Processing Time 0.026 seconds

A Study on the Measurement of 3-D object, make use of grid fringe generator (피치가변격자를 이용한 자유곡선 형상측정에 관한 연구)

  • 박윤창;정경민;박경근;장석준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.19-22
    • /
    • 2000
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially, when projecting a grid pattern over the object the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, new method for grid pattern generation system by polygonal mirror and Laser Diode. This system is applied the projection moire and the PMP.

  • PDF

A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method. (Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구)

  • 유원재;김도훈;강영준;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

A Study on the measurement of 3-D Object with Single Grating Shiftings (단일격자 이송을 이용한 영사식 3차원 물체 형상 측정에 관한 연구)

  • 박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.187-192
    • /
    • 1999
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially when projecting a grid pattern over the object, the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, the projection moire are compared with the PMP mathematically, and it is shown that PMP can generate moire image with simple mathematical computations. Experimental works are also carried out showing the same results. It is shown that using a single gird pattern, moire image can be obtained directly without any mathematical operation when some conditions are satisfied.

  • PDF

Image Enhancement for 3D Shape Measurement Using Large Aperture Projection System (오목거울을 이용한 3차원 형상측정을 위한 모아레 영상 획득 방법)

  • Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.327-333
    • /
    • 2008
  • In general, a lens with large NA makes image quality better. There are many kinds of cheap concave mirrors with large aperture and NA. This paper presents a method that uses a large aperture projection imaging system to enhance the image used for 3D shape measurement. This method makes it possible to enhance reflection uniformity on the object surface and increases SNR (Signal to Noise Ratio). Using a large aperture lens, it is possible to obtain a brighter image, reducing the shading nature in the image boundary, and enhancing the reflection uniformity even on woven surfaces. Because of the exorbitant cost of a large aperture projection lens larger than 150 mm in diameter, a refractive lens was exchanged with a concave mirror resulting in the same optical effect. In experiment, changing NA $0.15{\sim}0.8$, image contrast was enhanced from 46 to 1.33. Incidentally, the effect of the concave mirror was tested successfully through the experiment.

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 김도훈;유원재;박낙규;강영준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image (노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법)

  • Kim, Kuk-Won;Kim, Min-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.909-916
    • /
    • 2009
  • This paper presents the automatic vision algorithm to generate and calibrate reference phase plane to improve the accuracy of 3D measuring machine of using phase shifting projection moire method, which is not traditional N-bucket method, but is based on direct image processing method to the pattern projection image. Generally, to acquire accurate reference phase plane, the calibration specimen with well treated surface is needed, and detailed calibration method should be performed. For the cost reduction of specimen manufacturing and the calibration time reduction, on the specimen, not specially designed, with general accuracy level, an efficient calibration procedure for the reference phase generation is proposed. The proposed vision algorithm is developed to extract the line center points of the projected line pattern from acquired images, derive the line feature information consisting of its slope and intercept by using sampled feature points, and finally generate the related reference phase between line pairs. Experimental results show that the proposed method make reference phase plane with a good accuracy under noisy environment and the proposed algorithm can reduce the total cost to make high accurate calibration specimen, also increase the accuracy of reference phase plane, and reduce the complex calibration procedure to move grid via N-bucket algorithm precisely.

A Study of the Back Shape of the Children in Elementary and Middle Schools Using the Phase-shifting Scanning Grating Projection moire (위상천이 주사격자 영사식 모아레 간섭계를 이용한 초.중학생의 배부체형고찰)

  • 유한길;민병일;박동석
    • The Journal of Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.148-158
    • /
    • 2000
  • Objective : The purpose of this study was to investigate the back shape of school children using the phase-shifting scanning grating projection moire interferometer, which was developed by the Korea Advanced Institute of Science and Technology and is useful in evaluating three dimensional back shape. Methods : In this study the subjects consisted of 1,358 pupils [711 boys(52.36%), 647 girls(47.64%)] attending elementary and middle schools in Seoul. Their ages ranged from nine to fifteen and the average age was 12.2. With the phase-shifting scanning grating projection moire interferometer, the posterior view of the body were taken to see if there are correlations of moire fringe number, width difference between left and right, and correlation between differences in moire fringe number and width on both sides in the scapular, lumbar and gluteal regions. Results : The results were as follows : I. More frequent findings of fringe were observed on the right in all regions : in the scapular region, 309 boys(43.4%) and 156 girls(24.2%) had more fringe numbers on the right side; in the lumbar region, 68 boys(9.5%) and 11 girls(1.7%); and in the gluteal region, 160 boys(22.4%) and 63 girls(9.8%). Such tendency was striking especially in the scapular and lumbar regions, and in boys rather than in girls. In the scapula, 661 subjects(48.7%) with one moire fringe on either side need further attention and 110 subjects(8.I %) with two or more are required to do follow-up radiography for scoliosis. 2. In an analysis of width difference in the trunk, the left side is wider in all regions except for the gluteal region in boys : in the scapular region 21 boys(3.0%) and 103 girls(15.9%); in the lumbar region, 87 boys(12.2%) and 250 girls(38.6%); and in the gluteal region 197 girls(30.4%) had a wider left side and 45 boys(6.3%) showed a wider right side. 3. In correlation analysis of the number of moire fringe and width difference in each region, the side where more moire fringes were observed was significantly wider in the lumbar and gluteal regions, but not in the scapular region.(p<0.01) Conclusions : From these results, it is concluded that the back shape of elementary and middle school students in Seoul shows that the right side had more moire fringes; the left side was wider; and especially in the lumbar and gluteal regions the side where more moire fringes were observed was wider.

  • PDF