Analysis of calcium fluoride single crystal grown by the czochralski method (초크랄스키 방법으로 성장한 CaF2 단결정 분석)

  • Lee, Ha-Lin;Na, Jun-Hyuck;Park, Mi-Seon;Jang, Yeon-Suk;Jung, Hea-Kyun;Kim, Doo-Gun;Lee, Won-Jae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.6
    • /
    • pp.219-224
    • /
    • 2022
  • CaF2 single crystal has a large band gap (12 eV), and it is used for optical windows, prisms, and lenses due to its excellent transmittance in a wide wavelength range and low refractive index. Moreover, it is expected to be one of the materials for ultraviolet transmissive laser optical components. CaF2 belongs to the fluoride compounds and has a face-centered cubic (FCC) structure with three sub-lattices. The representative method for CaF2 single crystal growth is Czochralski, which method has the advantages of high production efficiency and the ability to make large crystals. In this study, X-ray diffraction (XRD), X-ray rocking curves (XRC) measurement, and chemical etching were performed to analyze the crystallinity and defect density of the CaF2 single crystals, grown by the Czochralski method. Fourier-transform infrared spectroscopy (FT-IR) and UV-VIS-NIR spectroscopy systems were used to investigate the optical properties of the CaF2 crystal. The provability of various applications, including UV application, was systematically investigated with various analysis results.

Development of 3D Reverse Time Migration Software for Ultra-high-resolution Seismic Survey (초고해상 탄성파 탐사를 위한 3차원 역시간 구조보정 프로그램 개발)

  • Kim, Dae-sik;Shin, Jungkyun;Ha, Jiho;Kang, Nyeon Keon;Oh, Ju-Won
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.3
    • /
    • pp.109-119
    • /
    • 2022
  • The computational efficiency of reverse time migration (RTM) based on numerical modeling is not secured due to the high-frequency band of several hundred Hz or higher for data acquired through a three-dimensional (3D) ultra-high-resolution (UHR) seismic survey. Therefore, this study develops an RTM program to derive high-quality 3D geological structures using UHR seismic data. In the traditional 3D RTM program, an excitation amplitude technique that stores only the maximum amplitude of the source wavefield and a domain-limiting technique that minimizes the modeling area where the source and receivers are located were used to significantly reduce memory usage and calculation time. The program developed through this study successfully derived a 3D migration image with a horizontal grid size of 1 m for the 3D UHR seismic survey data obtained from the Korea Institute of Geoscience and Mineral Resources in 2019, and geological analysis was conducted.

Improvement in flow and noise performances of small axial-flow fan for automotive fine dust sensor (차량용 미세먼지 센서용 소형 축류팬의 유동과 소음 성능 개선)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Inhiug Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.7-15
    • /
    • 2023
  • Recently, as interest in air quality in vehicles increases, the use of fine dust detection sensors for air quality measurement is becoming common. An axial-flow fan is inserted in the fine dust sensor installed in the air conditioning system in the vehicle to prevent dust from sinking directly on the sensor. When the sensor operates, the flow noise caused by the rotation of the axial-flow fan acts as a major noise source of the fine dust sensor. flow noise is recognized as one of the product competitiveness of fine dust sensors. In this study, the noise was gradually reduced at the same flow rate by improving the flow performance of the small axial flow fan. First, a virtual fan performance tester consisting of about 20 million grids was developed to analyze the aerodynamic performance of the target small axial-flow fan. In addition, the flow field was simulated by using compressible Large Eddy Simulation for direct computation of flow noise as well as high-accurate prediction of flow rate. The validity of numerical method are confirmed through the comparison of predicted results with experimental ones. After the effects of pitch angle on flow performance were analyzed using the verified numerical method, the pitch angle was determined to maximize the flow rate. It was found that the flow rate was increased by 8.1 % and noise was reduced by 0.8 dBA when the axial-flow fan with the optimum pitch angle was used.

Improvement and Operation of Urban Inundation Forecasting System in Seoul (서울시 도시침수 예측시스템의 개선 및 운영)

  • Shim, Jea Bum;Kim, Ho Soung;Gang, Tae hun;Lee, Byong Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.481-481
    • /
    • 2021
  • 서울시는 '10년, '11년, '18년의 기록적인 호우로 인해 막대한 재산피해를 기록하였다. 이로 인해 서울시는 수재해 최소화 대책의 필요성을 인지하여 방재시설물 확충 등의 구조적 대책과 함께 침수지역 예측, 호우 영향 예보와 관련된 비구조적 대책 수립을 위해 노력하고 있다. 그 일환으로 2018~2019년 『서울시 강한 비구름 유입경로 및 침수위험도 예측 용역』 수행을 통해 레이더 실황강우 기반의 강한 비구름 이동경로 추정 기술, 강우시나리오 기반의 침수위험지역추정 기술이 적용된 서울시 도시침수 예측시스템을 개발하였다. 또한, 침수피해에 선제적으로 대응하기 위해 2019~2020년 『서울시 내수침수 위험지역 실시간 예측기술 개발』을 통하여 이류모델 기반의 예측강우정보 추정 기술, 예측강우정보 기반의 실시간 침수위험지역 추정기술을 적용하였다. 현재 서울시 도시침수 예측시스템은 서울시 전역의 강우 및 침수정보를 제공하며, 관로 113,286개(전체 385,768개), 맨홀 106,097개(전체 272,133개), 빗물펌프장 117개소(전체 121개소)가 반영되어 있다. 서울시 도시침수 예측시스템에서는 서울시 25개 자치구를 대상으로 실황 및 예측 강우정보, 강한 비구름에 대한 이동경로정보, 시나리오 및 실시간 침수정보를 제공하고 있다. 강우정보는 10분 및 1시간 단위 AWS 실황정보와 10분 단위 이류모델 기반 예측정보, 1시간 단위 LDAPS 기반 예측정보를 제공한다. 또한, 레이더 실황정보를 통해 판별된 강한 비구름에 대해 10분 단위 1시간 예측경로를 제공한다. 침수정보는 총강우량, 강우지속기간, 빗물받이효율 조건을 반영한 강우시나리오 기반의 6m 고해상도 격자단위 침수시나리오 정보와 자치구별 침수위험정보를 제공한다. 또한, 이류모델 기반의 레이더 예측정보를 이용하여 실시간 침수 예측정보를 제공한다. 향후 서울시 내 모든 수방시설물의 적용, 관로 유출구별 기점수위 반영, 관측자료를 이용한 도시유출 및 도시침수 모델 최적화 등 지속적으로 고도화를 수행하고자 하며, 서울시 도시침수 예측시스템을 통해 서울시 및 자치구 풍수해 담당자가 침수피해를 대비, 대응할 수 있을 것으로 기대된다.

  • PDF

Propagation Analysis of Dam Break Wave using Approximate Riemann solver (Riemann 해법을 이용한 댐 붕괴파의 전파 해석)

  • Kim, Byung Hyun;Han, Kun Yeon;Ahn, Ki Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5B
    • /
    • pp.429-439
    • /
    • 2009
  • When Catastrophic extreme flood occurs due to dam break, the response time for flood warning is much shorter than for natural floods. Numerical models can be powerful tools to predict behaviors in flood wave propagation and to provide the information about the flooded area, wave front arrival time and water depth and so on. But flood wave propagation due to dam break can be a process of difficult mathematical characterization since the flood wave includes discontinuous flow and dry bed propagation. Nevertheless, a lot of numerical models using finite volume method have been recently developed to simulate flood inundation due to dam break. As Finite volume methods are based on the integral form of the conservation equations, finite volume model can easily capture discontinuous flows and shock wave. In this study the numerical model using Riemann approximate solvers and finite volume method applied to the conservative form for two-dimensional shallow water equation was developed. The MUSCL scheme with surface gradient method for reconstruction of conservation variables in continuity and momentum equations is used in the predictor-corrector procedure and the scheme is second order accurate both in space and time. The developed finite volume model is applied to 2D partial dam break flows and dam break flows with triangular bump and validated by comparing numerical solution with laboratory measurements data and other researcher's data.

Evaluation of Bursting Behavior in Anchorage Zone of PSC I Girders (PSC I 거더의 정착부 파열거동 평가)

  • Choi, Kyu Chon;Park, Young Ha;Paik, In Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.329-336
    • /
    • 2010
  • An experimental study to evaluate bursting behavior in anchorage zone of the standard PSC I girders (span length : 30 m) has been carried out. The arrangement of bursting reinforcement in anchorage zone of the standard PSC I girders is considered to be designed without accurately reflecting the stress flows in the end zone of the PSC I girders caused by presstressing forces of the tendons. Also, due to excessive arrangement of the bursting bars, the workability of the girder is decreased greatly. In this study, three specimens with the same dimensions as the end zone of the standard PSC I girder are prepared and the experiment is carried out by applying PS forces. The bursting reinforcement of each specimen consists of 100 mm, 200 mm, and 300mm spacings, respectively. The experimental results show that the range of the PS forces to cause crack in the anchorage zone of the specimen are more than 1.6 times of the design PS forces. The bursting cracks occur in the vertical direction on the inside of all specimens. After applying 2.7 times of the design PS force, some of the transverse bursting reinforcements only in the specimen reinforced by 300 mm spacing yielded. The experimental results show that the anchorage zone of the standard PSC I girders arranged by 300 mm spacing of the bursting reinforcements which is the maximum spacing allowed in the road bridge design specifications, can be considered safe enough.

Properties of Liquid Crystalline Polyester/Poly(ethylene 2,6-naphthalate) Blend Fibers (액정 폴리에스테르/PEN 블렌드 섬유의 성질)

  • Kim, Won;Kim, Young-Yong;Son, Jung-Sun;Yun, Doo-Soo;Han, Chul;Choi, Jae-Kon;Jo, Byung-Wook
    • Elastomers and Composites
    • /
    • v.37 no.4
    • /
    • pp.244-257
    • /
    • 2002
  • A thermotropic liquid crystalline polymer(TLCP) which has flexible butylene/hexylene spacers in the main chain and a triad aromatic ester type mesogenic unit containing a naphthyl group was prepared by solution polycondensation. The in-situ composites based on poly(ethylene 2,6-naphthalate) (PEN) and a thermotropic liquid crystalline polymer(TLCP) were prepared and melt spun at different TLCP contents and different draw ratios to produce monofilaments. Blends of the TLCP with PEN were investigated in terms of thermal, mechanical properties and morphology. The TLCP synthesized showed nematic mesophasic behavior and its transition temperature to isotropic melt from mesophase was 249℃. The blends showed well dispersed TLCP phases in the PEN matrix without macroscopic phase separation. Inclusion of TLCP in the blends decreased the cold crystallization temperature of PEN in the blend, therefore, the TLCP acts as a nucleating agent in the blend and showed good interfacial adhesion between the dispersed LCP phases and PEN matrix with domain sizes 40~50 nm in diameter and well developed fibrillation in the monofilaments. The TLCP acted effectively as a reinforcing material in the PEN matrix at the 10wt% level, it led to an increase of initial modulus up to 270% and tensile strength by 235%, while the elongation rate increasing with higher draw ratios.

Development of a window-shifting ANN training method for a quantitative rock classification in unsampled rock zone (미시추 구간의 정량적 지반 등급 분류를 위한 윈도우-쉬프팅 인공 신경망 학습 기법의 개발)

  • Shin, Hyu-Soung;Kwon, Young-Cheul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.2
    • /
    • pp.151-162
    • /
    • 2009
  • This study proposes a new methodology for quantitative rock classification in unsampled rock zone, which occupies the most of tunnel design area. This methodology is to train an ANN (artificial neural network) by using results from a drilling investigation combined with electric resistivity survey in sampled zone, and then apply the trained ANN to making a prediction of grade of rock classification in unsampled zone. The prediction is made at the center point of a shifting window by using a number of electric resistivity values within the window as input reference information. The ANN training in this study was carried out by the RPROP (Resilient backpropagation) training algorithm and Early-Stopping method for achieving a generalized training. The proposed methodology is then applied to generate a rock grade distribution on a real tunnel site where drilling investigation and resistivity survey were undertaken. The result from the ANN based prediction is compared with one from a conventional kriging method. In the comparison, the proposed ANN method shows a better agreement with the electric resistivity distribution obtained by field survey. And it is also seen that the proposed method produces a more realistic and more understandable rock grade distribution.

Analysis of Precipitation Characteristics of Regional Climate Model for Climate Change Impacts on Water Resources (기후변화에 따른 수자원 영향 평가를 위한 Regional Climate Model 강수 계열의 특성 분석)

  • Kwon, Hyun-Han;Kim, Byung-Sik;Kim, Bo-Kyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.525-533
    • /
    • 2008
  • Global circulation models (GCMs) have been used to study impact of climate change on water resources for hydrologic models as inputs. Recently, regional circulation models (RCMs) have been used widely for climate change study, but the RCMs have been rarely used in the climate change impacts on water resources in Korea. Therefore, this study is intended to use a set of climate scenarios derived by RegCM3 RCM ($27km{\times}27km$), which is operated by Korea Meteorological Administration. To begin with, the RCM precipitation data surrounding major rainfall stations are extracted to assess validation of the scenarios in terms of reproducing low frequency behavior. A comprehensive comparison between observation and precipitation scenario is performed through statistical analysis, wavelet transform analysis and EOF analysis. Overall analysis confirmed that the precipitation data driven by RegCM3 shows capabilities in simulating hydrological low frequency behavior and reproducing spatio-temporal patterns. However, it is found that spatio-temporal patterns are slightly biased and amplitudes (variances) from the RCMs precipitation tend to be lower than the observations. Therefore, a bias correction scheme to correct the systematic bias needs to be considered in case the RCMs are applied to water resources assessment under climate change.

The Effect of Mg/W Addition on the Metal-insulator Transition of VO2 Using Spark Plasma Sintering (통전활성소결법으로 제조한 VO2의 금속-절연체 전이 특성에 W와 Mg 첨가가 미치는 영향)

  • Jin, Woochan;Kim, Youngjin;Park, Chan;Jang, Hyejin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.63-69
    • /
    • 2022
  • Vanadium dioxide shows a unique and interesting property of metal-insulator transition, which has attracted great attention from the viewpoints of fundamental materials science and industrial applications. In this study, the effect of Mg and W addition on the metal-insulator transition of VO2 were investigated for the bulk materials that are prepared by spark plasma sintering. The X-ray diffraction analysis of the sintered specimens revealed that the lattice parameters barely change, and the secondary phases are present. The transition temperature of MIT appears in the range of 64.2-64.6℃, regardless of the impurity element and content. On the other hand, the addition of Mg and W alters the electrical conductivity, i.e., the electrical conductivity increases by a factor of up to 2.4 or decrease by a factor of up to 57.4 depending on the impurity type and its content. The thermal conductivity showed the values of 1.8~2.5 W/m·K below the transition temperature, and the values of 1.9~2.8 W/m·K above the transition temperature. These changes in electrical and thermal conductivities can be attributed to the combination of the change in charge carrier density, the impurities as scattering centers, and the change in microstructures.