• Title/Summary/Keyword: 격리도

Search Result 1,283, Processing Time 0.031 seconds

Mulit-Layer Directional Coupler With Enhaned Coupling and Isolation (개선된 결합도와 격리도 특성을 갖는 다층 방향성 결합기)

  • Park jeong hoon;Lee Jin taek;Chun Dong wan;Shin Chul-chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.10A
    • /
    • pp.1215-1222
    • /
    • 2004
  • In this paper, we proposed the directional coupler using two layer microstrip substrate which is improved coupling and isolation. Modified two-layer directional coupler is the structure which is added to the one-layer on the signal line and located the floating conductor on the added layer. Also, we applied the aperture on the ground plane in order to enhancing the coupling value, and located the conductor in order to enhancing the isolation and VSWR according to S$_{11}$. As a result, proposed two-layer directional coupler has about 2 dB more higher coupling and 20 dB more higher isolation than conventional couplerer

Study on Improvement of the Array Antenna Performance by Isolation Enhancement (격리도 향상을 통한 배열안테나의 성능개선 연구)

  • Park, Minseo;Lee, Jae-Gon;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.229-238
    • /
    • 2016
  • In this paper, we have studied isolation enhancement using a suppression of surface wave to improve performance of array antenna. To reduce isolation between elements of array antenna, perfect magnetic conductor(PMC) and SOFT-surface is designed and located at center of ground plane, isolation and gain is simulated by commercial full wave simulator(HFSS). As a result, isolation of more than 40 dB and gain improvement of 2.2 dBi are obtained at E-plane array in case of both PMC and SOFT-surface. At H-plane array, air coupling is dominant compared to coupling by surface wave. It is conclude that this study is useful for design of compact array antenna and performance improvement of array antenna.

A Study on the Improvement of MIMO Antenna Isolation for Mobile Applications (휴대 단말기용 MIMO 안테나의 격리도 향상에 관한 연구)

  • Yoon, In-Seop;Yan, Xiao-Jia;Kim, Sang-Uk;Jo, Yun-Hyun;Park, Hyo-Dal
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.9
    • /
    • pp.987-992
    • /
    • 2015
  • In this paper, neutralization line structure have been employed to improve the isolation between the MIMO antenna system. The proposed MIMO antenna size is $116mm{\times}64mm{\times}5mm$ and designed on FR-4(${\varepsilon}r=4.4$) ground substrate. Neutralization line was applied to enhance isolation between the each antenna elements. The fabricated antenna satisfied a VSWR below 3 in LTE band B13 and the isolation between the MIMO antenna system is presented below -15dB. On the H-plane, antenna shows an omnidirectional pattern. In LTE band B13, the antenna presents a gain of a -2.6dBi ~-1.18dBi and radiation efficiency of 33.49% ~ 46.45%. Comparing measurement result with the outcome of simulation, the proposed MIMO antenna is expected to be applied for mobile application.

An Experimental Study on the Characteristics of Seismic Isolators under Extreme Conditions (교량 지진격리받침의 극한특성에 대한 실험적 고찰)

  • Kwahk, Im-Jong;Yoon, Hye-Jin;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.105-108
    • /
    • 2008
  • For the early seismic isolation design in Korea, foreign products of isolation bearings were used. But these days, the application of domestic products of isolation bearings is increasing. However various experimental studies can be found very seldom on the extreme and lonr term behaviors of isolation bearings. In this study, we considered the laminated rubber type isolation bearings that have many application cases in Korea and we evaluated their shear strength, long term characteristics such as aging and creep affecting shear strength of bearings in long term period. For the reality of experiments, fabricated isolation bearing specimens are designed for a real structure and shear loading was applied under design compressive loads. To evaluated aging effect, the specimens were exposed to high temperature environment for certain period and their shear properties were measured to compare with their original values. Also we measured creep amount of isolation bearings under constant compressive load for 1,000 hours and estimated creep amount after 60 years compatible with general life cycle of bridges.

  • PDF

Isolation Improvement of a Broadband Antenna Using a High-Permeability Substrate (고투자율 자성기판을 이용한 광대역 안테나 격리도 특성 개선)

  • Hur, Jun;Kay, Youngchul;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.24-29
    • /
    • 2015
  • In this paper, we propose a method of isolation improvement for broadband antennas using a high-permeability substrate. The substrate is applied for a planar monopole antenna based on near-field analysis to maintain radiation characteristics at its operating frequency while improving isolation by minimizing mutual coupling with nearby antennas at other frequency bands. To verify isolation improvement, we compare performance variations of $S_{21}$ according to the existence of the substrate using the proposed antenna and a reference antenna whose operating frequency is 2 GHz. As a result, the radiation characteristics are maintained, and $S_{21}$ performance is improved by more than 5~10 dB in the frequency band of greater than 2 GHz, which demonstrates the isolation can be improved by using the high-permeability substrate.

Feasibility Study of MR Elastomer-based Base Isolation System (MR 엘라스토머를 이용한 기초격리 시스템에 대한 타당성 연구)

  • Jang, Dong-Doo;Usman, Muhammad;Sung, Seung-Hoon;Moon, Yeong-Jong;Jung, Hyung-Jo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.6
    • /
    • pp.597-605
    • /
    • 2008
  • The feasibility study of a newly proposed smart base isolation system employing magneto-rheological elastomers(MREs) has been carried out. MREs belong to a class of smart materials whose elastic modulus or stiffness can be adjusted by varying the magnitude of the magnetic field. The base isolation systems are considered as one of the most effective devices for vibration mitigation of civil engineering structures such as bridges and buildings in the event of earthquakes. The proposed base isolation system strives to enhance the performance of the conventional base isolation system by improving the robustness of the system wide stiffness range controllable of MREs, which improves the adaptability and helps in better vibration control. To validate the effectiveness of the MRE-based isolation system, an extensive numerical simulation study has been performed using both single-story and five-story building structures employing base isolated devices under several historical earthquake excitations. The results show that the proposed system outperformed the conventional system in reducing the responses of the structure in all the seismic excitations considered in the study.

Isolating Subsystems by Valves in a Water Distribution System and Evaluating the System Performance (상수관망에서의 밸브에 의한 관의 부분적 격리와 상수관망의 효율성 평가)

  • Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.585-593
    • /
    • 2005
  • Recent concerns regarding protecting, identifying, isolating, redundant routing and dewatering of subsystems of water distribution networks have led to the realization of the importance of valves in these systems. Valves serve two purposes namely, flow and pressure control and isolating subsystems due to breakage or contaminant containment. In this paper, valves are considered from the point of view of subsystem isolation. When a water main is required to be closed, it may be in general necessary to close several other pipes in addition to the broken pipe itself depending on the distribution of adjacent valves. This set of pipes is defined as a segment. In this paper a segment analysis for isolating pipes is present and based on the segment analysis, we suggested the Valve Importance Index and the 7 performance indicators to evaluate the system performance. The suggested methodology is applied to a real network to verify the applicability of the methodology.

A Study on the Design and Implementation of Simulated Signal Generator for VHF Radar with High Interference and Immunity Characteristics (간섭신호 내성 및 격리도 특성이 우수한 초단파 레이다용 모의신호 발생장치의 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung;Lee, Sung-Je;Jang, Youn-Hui
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.27-32
    • /
    • 2019
  • This study describes the design and implementation of a simulated signal generator to demonstrate the performance of VHF band radar for the detection of small targets in RCS(Radar Cross Section). The transmission and reception antenna beam widths used in the simulated signal generating apparatus may be large, which may cause problems in the degree of isolation. Interference signal immunity and isolation characteristics are improved by considering operating conditions of VHF radar to solve isolation of antennas. Simulated signal generator performs the following: VHF radar transmission and reception correction, simulation signal generation, target Doppler, RCS and distance simulation, remote control, and GPS clock synchronization function. After the fabrication of the simulated signal generator, the main characteristics, such as the output characteristics and the reflection signal simulations, were tested. When the microwave radar assembly is completed in the future, it will be utilized for the performance evaluation of VHF radar.

Isolation valve system design account for water quality failure based on graph theory (그래프이론 기반 수질사고 예방형 상수도 관망 밸브 시스템 설계)

  • Park, Kyeongjin;Lee, Seungyub
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.185-185
    • /
    • 2022
  • 상수도 관망의 운영 단계에서 비정상상황의 발생은 필연적으로 발생하며, 비정상상황 발생 시상수도 관망 내 설치된 제수 밸브의 차폐를 통해 해당 구역의 격리 후 복구를 진행한다. 일반적으로 제수밸브를 통해 격리될 수 있는 최소 구역은 세그먼트로 정의하고, 제수밸브 설치 시 세그먼트의 격리로 인한 상수도 관망의 피해를 줄일 수 있도록 위치를 선정한다. 제수 밸브를 통한 격리 시 상수도 관망의 흐름 경로와 유향, 유속의 변화와 같은 수리적 특성 변화가 불가피하다. 지난 '19년도에 발생했던 3건의 수질 사고가 수리적 특성 변화에서 기인했던 것을 고려할 때, 제수밸브 차폐로 상수도 관망의 부분 격리 시 발생 가능한 수리적 특성 변화에서도 수질 사고가 야기될 가능성이 있다. 기존 제수밸브 위치를 결정한 연구들을 보면, 대부분 제수밸브 위치에 따라 결정된 세그먼트의 격리 시 수압 저감을 고려하여, 격리 시에도 상수도 관망의 성능을 최대한 유지할 수 있도록 결정하는 것이 일반적이다. 다만, 앞서 언급한 것과 같이 격리 시 발생 가능한 수리적 특성 변화로, 수압 저감 외에도 예기치 못한 수질 사고의 발생 원인이 되기도 한다. 이에 따라 제수밸브의 최적위치를 결정할 때 수리적 특성 변화를 고려해야 예지치 못한 2차 피해를 줄일 수 있을 것이다. 이에 본 연구는 그래프이론을 활용하여 격리 전후 관로의 유향 변화를 최소화하도록 제수밸브 최적 위치 결정하는 방법론을 제안한다. 그래프이론은 망의 형태를 가지는 상수도 관망의 연결성을 정량화할 수 있으며, 본 연구에서는 수리학적 거리 인자를 적용하여 격리 시에도 각 수요절점이 최소 경로를 확보할 수 있도록 유도하였다. 해당 방법론은 가상 관망에 적용하여 수리학적 거리 인자에 따른 설계와 기존 상수도 관망 성능 극대화 설계 안을 비교하였다. 또한 수질 사고 위험도 인자를 정의하여 해당 인자에 따른 각 설계 안의 효과를 분석하였다. 본 연구는 향후 수질 사고를 고려한 밸브 시스템의 설계 및 운영에 활용할 수 있을 것으로 기대한다.

  • PDF

Analysis of Data Isolation Methods for Secure Web Site Development in a Multi-Tenancy Environment (멀티테넌시 환경에서 안전한 웹 사이트 개발을 위한 데이터격리 방법 분석)

  • Jeom Goo Kim
    • Convergence Security Journal
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2024
  • Multi-tenancy architecture plays a crucial role in cloud-based services and applications, and data isolation within such environments has emerged as a significant security challenge. This paper investigates various data isolation methods including schema-based isolation, logical isolation, and physical isolation, and compares their respective advantages and disadvantages. It evaluates the practical application and effectiveness of these data isolation methods, proposing security considerations and selection criteria for data isolation in the development of multi-tenant websites. This paper offers important guidance for developers, architects, and system administrators aiming to enhance data security in multi-tenancy environments. It suggests a foundational framework for the design and implementation of efficient and secure multi-tenant websites. Additionally, it provides insights into how the choice of data isolation methods impacts system performance, scalability, maintenance ease, and overall security, exploring ways to improve the security and stability of multi-tenant systems.