• Title/Summary/Keyword: 게이지 R&R

Search Result 25, Processing Time 0.022 seconds

Review of Gauge R&R Studies by Restricted and Unrestricted Design in the Two-Factor Mixed Model (2인자 혼합모형의 제약과 비제약 설계에 의한 게이지 R&R 연구의 고찰)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.657-665
    • /
    • 2009
  • The paper reviews gauge R&R studies by two-factor mixed models including random and fixed factors. The two-factor mixed models include restricted models and unrestricted models considering the interaction of two factors. This study also classifies the models according to the number of factors, and the combination of various factors such as random factor, fixed factor, block factor and repetition type.

  • PDF

Calculation of Gauge Precisions by Measurement Experimental Design for Split Split Plots (2단분할법 측정 실험계획에 의한 게이지 정밀도 산정)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.649-657
    • /
    • 2009
  • The paper presents the measurement split split-plot models for saving the time and cost. The split split-plot designs developed are efficiently used to estimating the gauge R&R(Reproducibility & Repeatability) when the completely randomized design of all factors(such as high pressure and temperature) is expensive and time consuming. The models studied include three split split-plots considering the type of experimental units.

  • PDF

Development and Implementation of Experimental Design Process for Estimating the Measurement Precisions (측정 정밀도 추정을 위한 게이지 실험계획 프로세스 개발 및 적용)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.557-563
    • /
    • 2009
  • The research develops measurement processes for estimating and evaluating the gauge R&R(Reproducibility & Repeatability) using ANOVA(Analysis of Variance) of experimental design tools. The ten-step processes developed include experimental goal setting, the selection of characteristics(factors, levels), data model, ANOVA, EMS(Expected Mean Square), estimation of gauge precisions, and evaluation indexes. The three-factor combined measurement models are presented to show the processes developed in this paper.

  • PDF

Estimation of Gauge R&R by Variance Components of Measurement ANOVA (측정 ANOVA의 분산성분에 의한 게이지 R&R 추정)

  • Choi, Sung-woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.199-205
    • /
    • 2010
  • The research proposes the three-factor random measurement models for estimating the precision about operator, part, tool, and various measurement environments. The combined model with crossed and nested factors is developed to analyze the approximate F test by degrees of freedom given by Satterthwaite and point estimation of precisions from expected mean square. The model developed in this paper can be extended to the three useful models according to the type of nested designs. The study also provides the three-step procedures to evaluate the measurement precisions using three indexes such as SNR(Signal-To-Noise Ratio), R&R TR(Reproducibility&Repeatability-To-Total Precision Ratio), and PTR(Precision-To-Tolerance Ratio), The procedures include the identification of resolution, the improvement of R&R reduction, and the evaluation of precision effect.

A STUDY ON THE EFFECT OF POLYMERIZATION SHRINKAGE OF SEVERAL COMPOSITE RESIN USING STRAIN GAUGE (스트레인 게이지를 이용한 수종 수복재의 중합수축 영향 평가)

  • Lee, In-Cheon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.20-29
    • /
    • 2009
  • This study was performed to evaluate the effect of the shrinkage stress induced by polymerization process of several light curing filling materials according to filling methods. High power light curing unit which has a plasma arc lamp was used and filling materials used were Filtek $Z-250^{(R)}$ composite resin, $Dyract^{(R)}$ AP compomer and $Tetric^{(R)}$ Flow flowable composite resin. Cavities were prepared on the permanent molars with width 3 mm, height 3 mm and depth 1.5 mm and the filling materials were filled with 1 step, 2 step layering technique and 3 step oblique filling methods. The results can be summarized as follows; 1. Strain values showed rapid increase from the start of light curing followed by gradual decrease afterwards with time. 2. Although the shrinkage stress value of $Z-250^{(R)}$ were shown to be relatively higher than $Dyract^{(R)}$ AP and $Tetric^{(R)}$ Flow, no statistically significant could be found between tested materials(p>0.05). 3. There were no statistically significant difference between 3 filling methods when using $Dyract^{(R)}$ AP and $Z-250^{(R)}$(p>0.05). 4. There were no statistically significant difference between shrinkage stress values obtained from samples prepared by different filling methods and materials(p>0.05).

  • PDF

Evaluation of Measurement Precisions Using Approximate F Tests and EMS in the Gauge R&R Studies (게이지 R&R 연구에서 근사 F검정과 EMS를 이용한 측정 정밀도의 평가)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.209-216
    • /
    • 2009
  • A development in method of evaluating the measurement precisions using approximate F tests and variance components from expected mean square (EMS) is investigated. The research proposes three-factor mixed measurement models with the fixed and random factors. Unrestricted and unconstrained design work was rarely studied, while restricted and constrained designs have been significantly discussed. The unrestricted and unconstrained designs assume to be an independence of interaction. The proposed evaluation method about the measurement precisions can be extended to four-factor random measurement model or mixed measurement model. The study also presents the three evaluation indexes of precisions such as R&RTR (Reproducibility & Repeatability-To-Total Precision Ratio), PTR (Precision-To-Tolerance Ratio), and SNR (Signal-To-Noise Ratio). Numerical examples are proposed to evaluate the approximate F tests with Satterthwaite degrees of freedom and three indexes using the measurement precisions from EMS.

Study on Gamer Participation 2.0- Focus on Gamers' Communication Mediation (O-S-O-R) Model and Gamers' Communicative Ecology (게이머 참여 2.0 메커니즘 연구-게이머 커뮤니케이션 매개 O-S-O-R 모델과 게이머 커뮤니케이션 생태를 중심으로)

  • Jung, Chang Won
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.95-103
    • /
    • 2022
  • This study aims to understand a gamer participatory mechanism by comparing Gamer Participation 1.0(Bartz Liberation War) and Gamer Participation 2.0(Truck Demonstration). The process of gamers' political participation is analyzed by applying the communication-mediated O-S-O-R model with the case of gamers' truck protests caused by probability items' issue. This study found out that changes in the social, technological, and discursive layers that constitute the gamer's communication ecology led to diversification of communication channels and changes in the perception of games. Gamers utilized the technological layer of the media environment that presupposes immediate mutual communication, expressed opinions on issues in the mobilization process, and shared the necessity of participation to derive collective mobilization. Through communication, gamers were able to participate in socio-political issues with high participation thresholds. This study is significant in that it discussed the gamers' democratic citizenship and role as issue publics. The study suggests that the need for theoretical and methodological expansion to analyze various participatory cases.

The Measurement of Real Deformation Behavior in Pilot LNG Storage Tank Membrane (Pilot LNG저장탱크 멤브레인 실 변형 거동 측정)

  • Kim Y.K.;Yoon I.S.;Oh B.T.;Rong S.H.;Yang Y.M.;Kim J.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.27-31
    • /
    • 2005
  • The membrane to be applied inside of the LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature and pressure changes. It is very important to measure their thermal strains under LNG temperature by analytical and experimental stress analysis of the membrane. We have developed a stress measurement system using strain gages and measured the strain during cooldown and storing the LNG. We also analyzed the measured data by comparison with the FEM data.

  • PDF

Evaluation Method for Measurement System and Process Capability Using Gage R&R and Performance Indices (게이지 R&R과 성능지수를 이용한 측정시스템과 공정능력 평가 방법)

  • Ju, Youngdon;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.78-85
    • /
    • 2019
  • High variance observed in the measurement system can cause high process variation that can affect process capability badly. Therefore, measurement system analysis is closely related to process capability analysis. Generally, the evaluation for measurement system and process variance is performed separately in the industry. That is, the measurement system analysis is implemented before process monitoring, process capability and process performance analysis even though these analyses are closely related. This paper presents the effective concurrent evaluation procedure for measurement system analysis and process capability analysis using the table that contains Process Performance (Pp), Gage Repeatability & Reproducibility (%R&R) and Number of Distinct Categories (NDC). Furthermore, the long-term process capability index (Pp), which takes into account both gage variance and process variance, is used instead of the short-term process capability (Cp) considering only process variance. The long-term capability index can reflect well the relationship between the measurement system and process capability. The quality measurement and improvement guidelines by region scale are also described in detail. In conclusion, this research proposes the procedure that can execute the measurement system analysis and process capability analysis at the same time. The proposed procedure can contribute to reduction of the measurement staff's effort and to improvement of accurate evaluation.