• Title/Summary/Keyword: 검증장치

Search Result 2,808, Processing Time 0.037 seconds

A Study on Complexity Analysis of Extensible Profile Verification Software for Energy Storage System (에너지저장장치용 확장성 프로파일 검증 소프트웨어 복잡도 분석에 관한 연구)

  • Kwon, Hyeokyoung;Ryu, Youngsu;Park, Jaehong;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.17 no.5
    • /
    • pp.59-65
    • /
    • 2016
  • Recently, a study has been progressed about the energy storage system for resolving energy shortage problems in the world. The energy storage system can maximize energy storage system's energy usage by monitoring and controlling about all energy infrastructures on energy network. However, compatibility problems among main components or devices of the energy storage system are obstacles to development of energy storage system products. An extensible profile and extensible profile verification software being able to verify the extensible profile have been required in order to resolve compatibility problems. In this paper, the study on complexity analysis for the extensible profile verification software for the energy storage system is performed. A XML based profile and C language structure based profile are used for analysis of the profile verification software. The complexity of complex verification structure that parses the XML based profile several times and simple verification structure that parses the C language structure based profile are analyzed and compared. Time complexity, space complexity, and cyclomatic complexity are used for complexity analysis. By using these complexity analysis, the study result that compares and analyzes the complexity of XML based and C language structure based profile verification software is presented.

A Hybrid Dust Collector(Hi-Filter) for Reducing Dust Load (먼지부하 저감형 하이브리드 여과집진장치(Hi-filter))

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.223-226
    • /
    • 2002
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위해 실험실 규모의 장치를 이용한 실험을 통하여 장치의 최적 형상을 결정하고 그 성능을 검증하였다.(중략)

  • PDF

A Design and Fabrication of Hydromechanical Transmission Emulator (정유압 기계식 변속기 에뮬레이터의 설계 및 제작)

  • 방호균;이병선;김두근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1078-1082
    • /
    • 1996
  • 기계적 구동장치와 연계된 메카트로닉스 시스템에 대한 개발 시험은 비용, 공간 및 시간 등의 측면에서 제약을 받는다. 이러한 제약은 에뮬레이터를 이용한 개발 과정을 통해서 개선의 효과를 얻을 수 있다. 본 연구에서 설계 제작된 에뮬레이터는 전자 제어식 변속기에 적용된 장치로서 기계적 메카니즘 없이 전자 제어 메카니즘을 완전하게 에뮬레이션 할 수 있는 가능성을 보여준 것이다. 이러한 에뮬레이터를 이용하여 전자 제어장치의 개발 기간을 단축시키고 문제점을 빠르게 찾아낼 수 있다. 에뮬레이터의 개발은 수학적 모델링에 의해서, 장치에 대한 검증은 실차 시험을 통해 얻을 결과와 비교하여 수행된다.

  • PDF

Development and use of PC based combustion analyzer (PC를 사용하는 연소해석장치의 개발에 관한 연구)

  • Lim, B. J.
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.75-80
    • /
    • 1993
  • 널리 사용되는 IBM-PC를 기본으로 하여 고속도 데이터 처리가 가능한 연소 해석 장치를 개발 였다. 본 시스템은 상용의 A/D변환기와 C언어를 사용한 소프트웨어 및 PC 인터페이스 보드로 구성되어 있다. 본 연소 해석 장치의 특징은 모든 기능이 모니터 상에서 마우스로 지원되며, P 상에서 타 프로그램을 위한 데이터 변환이 용이하고 메모리의 확장이 기존의 상용 연소 해석 치에 비해 간편하다. 연구용 단기통 기관실험을 통하여 본 시스템을 검증하였다. 연소실 내의 력은 크랭크 각도로 0.1.deg.에서 1.deg.의 해상도로 분석할 수 있다.

  • PDF

The development of 200kVA Hybrid UPS (200kVA급 하이브리드형 무정전전원장치 개발)

  • Kim, Ji-Su;Lim, Seung-Beom;Lee, Won-Il;Kim, Ki-Beom;Kim, Eun-Duk
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.85-86
    • /
    • 2014
  • 본 논문은 에너지저장 기능을 갖는 200kVA급 무정전전원장치에 관한 것으로 평상시에는 무정전전원장치(UPS : Uninterruptible Power Supply) 기능을 수행하다 첨두부하시 또는 전력 부족시 에너지 저장 장치(ESS : Energy Storage System) 기능을 제공하는 기술이다. 제안된 시스템의 유효성을 실험을 통하여 검증한다.

  • PDF

A Study on Parameters of SUAV Landing Gear Orifice (SUAV 착륙장치 오리피스의 파라미터 연구)

  • Han, Jae-Do;Kang, Yeon-Sik;Ahn, Oh-Sung;Lee, Young-Sin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.99-104
    • /
    • 2009
  • In this paper, the drop characteristic of the small aircraft landing gear of SUAV has been analyzed and performed on orifice optimal design for shock absorption efficiency. The SUAV landing gear was simple oleo pneumatic type without metering pin. The landing gear was modelled by MSC ADAMS software. Drop test evaluation was conducted to confirm the analysis model. As a result of correlation between analysis and test results, it was verified that these results were coincided with very well. After confidence review of analysis model through the correlation between test and analysis results, design parametric study was performed by using confirmed analysis model. Optimal orifice size with best efficiency have been decided in this study.

A Study on Simulation of A Multiprocessor System (다중처리기 시스템의 시뮬레이션에 관한 연구)

  • Park, Chan-Jung;Shin, In-Chul;Rhee, Sang-Burm
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.10
    • /
    • pp.78-88
    • /
    • 1990
  • To evaluate the performance of a multiprocessor system, a discrete event model of memory interference in the system employing multiple-bus interconnection networks is proposed. An analytic model of the system is presented and then simulator models are implemented for cross-verifying the analytic results and simulation results. The simulator model takes as input the number of processors, the number of memory modules, the number of buses and the local memory miss ratio. The model produces as output the memory bandwidth, the processor, memory module and bus utilization and the bus contention ratio. Using the model in the design of the system, it is possible to evaluate the system performance by analyzing the interaction of the input parameters.

  • PDF

Control and Monitor of Heat Exchange Ventilation Facility by Smart Phone (스마트폰을 이용한 열교환기 환기장치의 제어 및 계측)

  • Chung, Myung-jin;Lee, Jin-ho;Hong, Jong-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1027-1029
    • /
    • 2015
  • Heat exchange ventilation facility is using for heating the inflow outside-air with warm outflow inside-air. Energy cost is saved and respiratory disease caused by temperature difference of air is prevented. In this paper, system for remote control and monitoring of heat exchange ventilation facility is developed. This system is applied in chicken breeding farm, and verification test of performance such as temperature and humidity control and monitoring is conducted. From verification test, temperature control error is measured as under 2degrees around the chicken breeding farm.

  • PDF

Power Compensator Control for Improving Unbalanced Power of AC Electric Railway (교류전기철도 불평형 전력 개선을 위한 전력보상장치 제어)

  • Woo, Jehun;Lee, Jeonghyeon;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.34-36
    • /
    • 2019
  • 본 논문은 교류전기철도의 불평형 부하로 인해 야기되는 3상 계통 전력의 불평형 특성을 저감하기 위한 제어 알고리즘을 제안하였으며, 전력보상장치 설계 및 이를 적용한 실험을 통해 성능을 검증하였다. 전기철도 시스템과 동일하게 3상 전압을 2개의 단상 전압으로 변환하는 스코트 변압기를 적용하였으며, M상과 T상 출력 단에 부하 및 3레벨 백투백 컨버터가 연계되어 구성된다. 백투백 컨버터는 M, T상의 불평형 부하 간 발생하는 유효전력의 차이를 실시간으로 감시하고 양방향 특성을 이용해 전력을 보상하는 역할을 수행한다. 백투백 컨버터의 유효전력은 동기좌표계 PI 제어를 통해 수행되며, DC 링크 전체 전압 및 밸런싱 제어는 시스템의 응답성 향상을 위해 M, T상 컨버터가 공동으로 분담하여 제어한다. 제안된 전력보상장치의 성능 확인을 위해 M상 5kW, T상 1kW 불평형 부하가 연계된 조건에서 시뮬레이션 및 실험을 진행하였으며, 실험 결과 전력보상장치의 동작 후 3상 전류의 불평형률이 65.04%에서 6.38%로 58.66% 저감되는 것을 통해 본 논문에서 제안하는 전력보상장치의 우수한 성능을 검증하였다.

  • PDF

Field Applicability Assessment of Degradation Diagnosis System for Distribution Power Cables (배전케이블 열화진단 장치의 현장적용성 평가)

  • Lee, Jae-Bong;Kim, Dong-Myung;Song, Il-Keun;Kim, Ju-Yong;Kim, Suk-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1131-1134
    • /
    • 2003
  • 이 논문은 현재 국내에서 사용하고 있는 배전용 케이블 열화진단장치인 완화전류 측정장치의 진단기준 개선을 위한 것이다. 현재까지 사용되던 직류 고전압을 이용한 누설전류 측정법을 대체하기 위해 사용되는 완화전류 측정장치는 국내 배전선로에서 수년간 현장적용을 실시하여 많은 케이블을 교체하였다. 하지만 완화전류 측정을 통해 교체한 케이블의 상태에 대해서는 검증되지 않은 상태이므로 완화전류 측정을 통한 교체기준이 국내 케이블에 적절한지 확인할 필요가 있다. 이는 케이블 유지보수에 있어서 중요한 사항으로서 교체기준이 부적절할 경우 열화진단을 통한 고장방지 목적을 달성할 수 없거나 건전한 케이블을 교체하여 불필요한 예산을 낭비하는 원인이 된다. 본 논문에서는 현장운전중인 선로를 선택하고 열화된 케이블의 절연성능 향상을 위해 실리콘을 주입하였다. 그리고 실리콘 처리후 케이블의 운전시간에 따른 열화진단 결과와 케이블 절연파괴강도를 비교하여 진단장치의 신뢰성을 검증하고자 하였다. 이것은 1년 동안의 현장시험 결과를 정리한 것이다.

  • PDF