• Title/Summary/Keyword: 검사 안정성

Search Result 819, Processing Time 0.034 seconds

Convergence Correlation Analysis of Physical Characteristics and Functional Movement Screen in Healthy Adults (정상 성인의 신체적 특성과 기능적 움직임 검사에 대한 융합적 상관관계 분석)

  • Kim, Hyun-Seung;Cho, Sung-Hyoun
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.87-93
    • /
    • 2020
  • The purpose of this study was to examine the convergence correlation between physical characteristics and functional movement screen(FMS). Overall, 193 adults with normal single measurement values participated in the study. For data analysis, we used the SPSS Ver. 26.0 statistical program to perform t-tests and to determine Pearson's correlation coefficients for variables. Data analysis revealed significant sex differences in the active straight-leg raise and trunk stability push up tests (P<.05). In addition, our data analysis also revealed a negatively correlation between body fat percentage and FMS tests, except in the shoulder mobility and active straight leg raise test. In the active straight leg raise, the quality of functional movement was higher in women than in men; while in the trunk stability push ups, the quality of functional movement was higher in men than in women. Therefore, we conclude that men should reinforce the flexibility of the lower extremities, and females should apply upper body muscular strength for better trunk stability movement.

A feasibility study on the stability securement on domestic inflatable boat by comparing foreign rules and regulations with Korea Water-related Leisure Activities Safety Act. (팽창식 보트의 국내외 시험 규정 비교를 통한 안정성 확보의 필요성 연구)

  • Yeong-Min Park;Ming-Su Kang;J ang-Gon Im;Hyen-Woo Kim
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.329-331
    • /
    • 2022
  • 국내 '수상레저기구 안전검사 기준(해양경찰청 고시)' 의 고무보트 안전검사 기준을 국제 표준 및 관련 법령(ISO-6185, 미국 ABYC 단체표준, 미국해양경비청 USCG, 뉴질랜드 해양법 NZ Maritime Law)과 비교를 통해 안정성(stability) 확보를 위하여 개선 방안을 제시하고자 한다. 현행 '수상레저기구 안전검사 기준'의 고무보트는 승선정원 13인 이상 및 특정 항해 구역에 대해서만 복원성 조건을 요구하고 있어 13인승 이하의 고무보트는 안정성 조건이 전무한 실정이다. 특히, 국제 표준 및 관련 법령과는 약 38개의 검사항목에 누락 또는 미흡한 차이가 있으며, 이에 국내 기준과 국제 표준과의 비교 분석을 통해 개인의 최소 안전을 담보 할 수 있는 고무보트의 안전성 확보 방안을 마련하고자 한다.

  • PDF

Intra- and Inter-rater Reliability of BioRescue (BioRescue의 측정자내와 측정자간 신뢰도)

  • Kim, Jin-hong;Choi, Bo-ram
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.348-352
    • /
    • 2018
  • BioRescue ($RMIng{\acute{e}}nierie$, Marseille, France) is able to assess dynamic and static balance when a test subject stands or sits over the platform. Although previous studies have examined the reliability of other balance measurement methods, little research has been conducted on the reliability of equipment such as BioRescue. This study examined the intra-rater and inter-rater reliability of BioRescue during balance assessment. Thirty-four healthy adults participated as subjects and two physical therapists participated as examiners to determine intra- and inter-rater reliability. BioRescue was used to conduct measurements during footprint (area and pressure), Romberg, and limit of stability tests. The footprint area and limit of stability tests yielded intra- and inter-rater reliability ICC values above 0.60 in all directions. However, the footprint pressure and Romberg tests yielded values below 0.60 in all directions. BioRescue showed good inter-rater and intra-rater reliability in measurements during footprint area and limit of stability tests. However, because the values of limits of stability show the difference between experienced and unskilled, skill is required for the accuracy of the equipment.

Utility Comparison of Chest Lateral Decubitus Projection with AP and PA Position (흉부 측와위 촬영 시 전후방향과 후전방향 검사의 유용성 비교)

  • Choi, Guirack
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.233-238
    • /
    • 2013
  • Chest lateral decubitus radiation exposure PA be carried out in general, but emergency patient or the patient's discomfort in the body examination had a lot of inconvenience. In this study, we compared AP and PA image quality, patient safety, and analysis of the examination effectiveness between the two tests was to evaluate the usefulness. Pleurisy or pneumothorax in patients with suspected or diagnosed chest lateral decubitus radiation exposure 30 consecutive patients (male 20 patients, 10 females) were included in the study. Image quality evaluation method microstructure of lung, wide areas of diagnosis, a clear air-fluid interface, the patient rotate, cardiac shadow and sharp diaphragmatic was based on Department of Radiology specialist, division of pulmonology resident blind test was evaluated by four people. Chest decubitus by radiation exposure the AP and PA position examination the usefulness of comparative analysis Image quality in the AP and PA, whereas there was no significant difference in attitude, Stability of the patient and Radiation's examination efficiency AP position compared to the position of PA scores were higher. PA position does not require a examination may be of AP position in a position to suggest that.

A Study on Stability evaluation in the freezing/thawing process of urine specimen analytes (소변 검체 분석물질의 냉/해동 과정 안정성 평가 연구)

  • Kim, Min Kyung;Kim, Sung Wook;Hwang, You Seong;Oh, Eunha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-62
    • /
    • 2022
  • The purpose of this study was to find a way to improve the stability and quality of urinalysis by checking the changes in the measurement values of representative clinical chemistry test items according to the repeated freezing and thawing before the urine test and the thawing process. All subjects were 10 healthy males, and the freeze and thaw stability test was performed using their urine samples. In the case of micro-albumin and amylase, there was no statistical significance at 37℃ with time, but at 42℃ and 60℃, there was a statistically significant change in the results with time. There were statistically significant changes in BUN, creatinine, uric acid, and glucose. As a result of long-term stability, after 7 days, glucose mutation increased and amylase decreased at 60℃. In the case of glucose and amylase, there was a statistically significant change in the results over time. To obtain accurate test results, accurate standardization of urinalysis including appropriate collection, storage, and storage methods of urine samples is required and systematic study of conditions for securing stability for each biomaterial is required.

Improvement in Multiple Input-Output Inspecting Method through Classified Scheduling (다중 입출력 검사 방식의 세분화된 스케줄링을 통한 개선)

  • Park, Wonchan;Ryu, Hwankyu;Kim, Jungho;Ahn, Kihong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.64-67
    • /
    • 2012
  • 복잡한 구조를 가진 케이블의 빠르고 정확한 검사를 위해 다중 입출력 검사 장치가 사용된다. 기존의 검사 장치의 제어 방법은 한번에 여러 가지 회선 특성을 가진 케이블의 검사가 불가능하며, 장치 안정성 및 검사 성능에 있어서 개선의 여지가 있으므로 이를 해결하기 위해서 본 논문에서는 입출력 장치의 검사 시퀀스 및 하드웨어 개량을 통한 개선 방법을 제안한다. 제안된 방법은 검사 명령 및 검사 결과를 저장하는 데이터 패킷에서 검사 명령을 좀더 세분화하여 패킷을 최적화하고 중복 명령을 제거하였으며, 입출력 신호 충돌 가능성을 차단하였다. 또한, I2C 버스 양방향 회로를 사용하여 전압 레벨 차이를 극복하고 활용성을 높일 수 있었다.

A Fault-Tolerant Mobile Agent Scheme using Observer Agents (관찰자 에이전트를 이용한 이동 에이전트 결함 내성 기법)

  • 윤재환;박태순
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.133-135
    • /
    • 2004
  • 이동 에이전트 시스템의 안정성을 높이기 위해 지금까지 여러 가지 이동 에이전트 결함 내성 기법이 연구, 개발되어 왔다. 이동 에이전트의 결함 내성 기법은 크게 복제 기법과 검사점 기법으로 나뉘는데, 일반적으로 복제 기법이 검사점 기법보다 안정적이지만 복제와 동의 과정에 따르는 부하 때문에 효율성 면에서는 검사점 기법에 비해 떨어지게 된다. 이를 개선하기 위해 비동기 에이전트 복제, 동의 전용 에이전트의 사용, 고정된 동의 전용 에이전트의 사용 등 여러 기법이 개발되었다. 이들 중ㆍ고정된 동의 전용 에이전트 기법은 안정성과 성능 모두 높은 실험 결과를 보이나 실제 시스템에 적용하기 힘들다는 단점이 있는데 본 논문에서는 관찰자 에이전트라는 일종의 동의 전용 에이전트를 도입하여 고정된 동의 전용 에이전트 기법을 보완, 개선하는 방안을 제시한다.

  • PDF

Nondestructive Evaluation using Optical Methods (광학적 방법에 의한 비파괴 평가)

  • Kang, Young-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.213-226
    • /
    • 2001
  • 최근 가속화되어 가는 산업발전으로 인하여 산업구조물 및 기계 부품의 안정성 및 비파괴 검사에 대한 요구가 크게 대두되고 있다. 이는 곧 산업구조물 및 제품의 품질 향상을 위한 기존의 검사방법으로는 제품의 완성도를 높이기 어렵다는 것을 의미하며, 제품의 질을 향상시키기 위해서는 새로운 비파괴 평가방법이 필요하다는 것을 의미한다. 또한 모든 구조물의 보수 유지 및 안전성 진단의 차원에서 모든 산업적 구조물의 변형과 응력, 진동모드, 미소3차원 형상에 대한 평가 및 해석은 구조물의 수명과 관계되어 그 중요성이 크다 할 수 있다. 이에 본고에서는 기존의 비파괴검사 방법들이 많은 장점이 있음에도 불구하고, 단점을 극복할 수 있는 평가 기술로서, 고체재료 및 산업구조물 - 기계구조물, 전자 부품, 배관, 토목건축 구조물 등 - 의 변형, 결함, 균열, 응력 등을 검사 및 평가할 수 있는 광학적인 비파괴 평가 방법에 대해 소개하고자 한다.

  • PDF

Development of a Tele-operating Multi-Link Robot for Pipe Inspection (배관검사용 원격제어 다관절 로봇 개발)

  • Choi, You-Rak;Lee, Jae-Cheol;Chio, Young-Su;Kim, Jae-Hee;Lee, Nam-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.07a
    • /
    • pp.245-248
    • /
    • 2014
  • 산업플랜트에는 고온 고압 배관 시스템을 갖춘 곳이 많으며, 이 배관 시스템의 건전성은 매우 중요하게 취급된다. 배관의 건전성 유지를 위해서는 일정 기간 동안 배관의 안정성 검사를 수행하게 되는데, 배관 시스템의 복잡성과 위험성으로 인한 검사자의 접근 자체가 매우 어려운 상황이 빈번하게 발생한다. 이를 해결하기 위하여 로봇 개술을 적용하는 연구개발이 지속되고 있는데 본 논문에서는 5축 대관절 매니퓰레이터 형태의 배관 등반이 가능한 반자동 원격 제어 로봇의 개발에 대하여 기술한다. 이 로봇의 구현을 위해서는 로봇의 배관 인지 기술, 로봇의 배관 그리핑 기술, 5축 관절의 제어 기술, 그리고 원격제어기술등이 요구된다.

  • PDF