• Title/Summary/Keyword: 검사 결과

Search Result 16,659, Processing Time 0.06 seconds

매몰저장탱크 검사방법 개선 건의

  • Korea LPGas Industry Association
    • LP가스
    • /
    • s.87
    • /
    • pp.13-14
    • /
    • 2003
  • 주지하시는 바와 같이 2001.7.29부터 15년이상 경과된 지하매몰LPG저장탱크는 주위의 모래를 제거한후 피복을 벗겨 탱크외면검사를 하도록 고시(산자부고시 제2001-12호, 2001.1.29)가 개정된 바 있습니다. 그러나 이러한 검사방법은 여러 가지 문제점이 있어 저희 협회는 그동안 몇차례 이에대한 개선을 요청한 바 있으며, 실제로 탱크 외면의 모래를 제거한 후 검사를 실시한 결과 우려하였던 여러 문제점이 사실로 확인되었기에 첨부와 같이 매몰저장탱크의 재검사방법을 개선해 줄 것을 요청드리오니 긍정적으로 검토.반영하여 주시기 바랍니다.

  • PDF

A Study On Temperature Changes In Thigh According To Diagnostic Ultrasonography Scan Time (진단용 초음파 검사시간에 따른 허벅지의 온도 변화에 관한 고찰)

  • Kim, Ji-Won;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.201-206
    • /
    • 2012
  • Effect of prenatal ultrasound diagnosis have serious damage for the possibility has been reported very low. Long time ultrasound scan can rise the temperature in body tissues and affect the physical. Changes in body temperature have been studied with ultrasound scan time. Fetal ultrasonography were evaluated without the influence of time. The findings, ultrasound scan time in 40 minutes the temperature was reduced. 50 minute tissue temperature rose more than $1^{\circ}C$. If within 40 minutes of ultrasound to be safe guess

Development of the Test Tool of Astronomical Spatial Concept Level (천문학적 공간개념 수준에 관한 검사도구 개발)

  • Seo, Chang-Hyeon;Lee, Hang-Ro;Kim, Hee-Soo
    • Journal of the Korean earth science society
    • /
    • v.24 no.6
    • /
    • pp.508-523
    • /
    • 2003
  • This study has developed the test tool to measure the level of spatial concept in the astronomy education for high school students. The items of the test tool are composed of basic elements (spatial position, spatial reasoning, spatial variation) forming spatial concepts in the astronomy. The test tool was applied to the 274 high school students. As a result of item analysis, the test tool showed that the content validity was 98%, the reliability (KR 20) was 0.84, the measure the level of astronomical spatial concept for the high school students.

Implementation of Stable Interface for Clinic Laboratory Equipment (임상검사장비를 위한 안정적 인터페이스의 구현)

  • Lee, Jong-Hyeok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2355-2360
    • /
    • 2009
  • As for information system in hospital which digital hospital aims at, there are LIS(Laboratory Information System) and so on. Interface program gather the results from the clinic laboratory equipment and manage the results efficiently as well. To implement interface program, multi tasking and multi thread method is used. In this paper, we proposed the stable method after comparing and analyzing these two methods we present above through the simulation. Also we designed and implemented Interface program which satisfy the users' requirements applying the proposed method. The result of using the built interface program in the hospital field confirms that the program operates safely.

칭량장치

  • O, Do-Seok
    • 월간산업보건
    • /
    • s.84
    • /
    • pp.19-24
    • /
    • 1995
  • 우리나라는 60년대 초부터 80년대 후반까지 중화학공업의 육성에 급급한 나머지 각종 산업분야에서 사용 및 생산된 유해화학물질의 환경과 인간에 미치는 영향은 거의 무시되어왔기 때문에 80년대 후반부터 각종 유해화학물질로 인한 직업병이 노출되어 사회문제화 되었다. 따라서 시급하게 이들 유해화학물질을 관리해야 할 필요성이 대두되고 이를 위한 제도적 장치가 마련되었다. 바로 이것이 작업환경측정 및 임상검사에 대한 정도관리제도이다. 작업환경측정을 위한 정도관리는 작업환경측정에 관한 정도관리규정(노동부 고시 제 92-18호, 1992, 4, 16) 에 의거 한국산업안전공단에서 현재 매년 2회에 걸쳐 실시하고 있으며, 근로자의 임상시료에 대한 정도관리는 1977년 대한임상검사 정도관리학회에서 실시한 이래 현재까지 자율적으로 계속 실시되고 있고, 제도적으로는 근로자 건강진단 실시기준(노동부 고시 제 92-9호, 1992. 4. 2)에 의거 대한산업보건협회가 현재까지 70여개 대상기관에 대한 매년 2회를 실시하고 있다. 그러나 작업환경측정이나 임상시료에 대한 결과치의 신뢰도 증대가 요구되는 현시점에서 신뢰도 증진의 중요한 요소중의 하나인 검사기기의 정도관리는 더더욱 그 중대함을 더해가고 있으나 우리의 실정이 이를 만족시키지 못하고 검사기기에 대한 정도관리를 할 수 있는 참고할 서적이나 방법이 부족하여 관련분야의 실무자들이 많은 애로점을 갖고 있는 실정이다. 따라서 여기에서는 검사에 사용되는 각종 기기에 대한 기초원리, 사용목적, 검사순서, 적용범위, 취급상의 주의, 사용하는 입장에서의 보수관리에 대해 서술함으로써 작업환경측정이나 임상정도관리 및 기타 관련분야에서 공통으로 사용하는 검사기기에 대한 정도관리를 함으로써 더욱더 신뢰도 높은 결과를 얻는데 기여할 수 있는 것으로 기대된다. 또한 여기에 소개한 기초원리나 응용분야에서 부족한 점은 화학, 물리학 및 임상병리학 등 전문서적을 참고하여 주기 바란다.

  • PDF

The Development of X-ray image processing system for product inspection. (물품 검사를 위한 X-선 영상 처리 시스템 개발)

  • Moon, Ha-jung;Lee, Dong-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.826-828
    • /
    • 2014
  • Recently trend of product is miniaturization. As a result, We need products surface as well as products internal defect inspection. Generally, Inspection products in production process uses a lot of optical inspection. However, This is difficult to internal inspection of products. We used optical device instead of X-ray generator. At the same time, We have developed system to determine the product defect. First, obtain X-ray image from Machine vision function. Next, Measured value is recognize suitability within error range. otherwise recognize defect. Results presence of defective products can be stored by user.

  • PDF

A Study on the Relationship between CBC and EEG for Epilepsy Patients (뇌전증 EEG결과와 CBC결과의 관계연구)

  • Jo, Yoon-kyung;Sung, Hyun-Ho;Chae, Kyoung-Min
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.225-229
    • /
    • 2015
  • Epilepsy is a disorder that causes recurring seizures, and the most objective and useful test for detecting epilepsy is the electroencephalogram (EEG). The subjects of this study are 244 patients who received an EEG after being diagnosed with epilepsy at Seoul National University Hospital in 2014, and who have agreed to the purpose of the study. Based on the EEG results, subjects were divided into normal and abnormal groups with 122 subjects in each group, regardless of their gender and age, to investigate the correlation of EEG and complete blood cell count (CBC) test results. The four significant categories that displayed significant correlation between EEG results and CBC hematological measurements in this study were the white blood cell (WBC), red blood cell (RBC), neutrophil, and lymphocyte tests. The WBC (p<0.05) and neutrophil (p<0.01) showed a positive correlation with EEG results, while RBC (p<0.05) and lymphocyte (p<0.01) showed a negative correlation. One of the limitations of this study is that it is lacking the blood test result analysis according to the types of anti-epilepsy medicine. However, the analysis of EEG results by the same disease has significant meaning. Therefore, further studies are needed to statistically analyze more data in the future.

A Study on the Illumination Environment of Ultrasound Examination Room (초음파 검사실의 조도 환경에 관한 연구)

  • Im, In-Chul;Lee, Hyo-Yeong;An, Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • The purpose of study is provide the basic data for set up proper illuminance of examination room that put purpose of an empirical study basic data about examination environment setting of the ultrasonic examination on design the examination environment of a new ultrasonic examination. As a method, to investigate the ultrasonic environment related to illumination to take a survey on the ultrasonic examination about test object to 48 parts of six units of general hospital in Busan. As a result, All Door + Curtain showed high scores in analyzing the gender, age, examination part in the case of ultrasonic examination room shielding and LED and light source control is required in the case of kind of light source. In the ultrasonic examination environment survey, the illuminance brightness is average 10 Lux which is included illuminance brightness range recommended the WHO and CEC and illuminance brightness of ultrasonic examination waiting room(ultrasonic examination waiting room, corridor) indicate average 300~800 Lux and it satisfied hospital illumination environment more than 300 Lux recommended by KSA 3011. In conclusion, Basic data suggested that improved future ultrasonic examination environment or designed new examination room on the basis of analysis result of general background and ultrasonic examination related to environment factor.

Detection of Object Images for Automatic Inspection based on Machine Vision (머쉰비전기반 자동검사를 위한 대상 이미지 검출)

  • Hong, Seung-woo;Hong, Seung-beom;Lee, Kyou-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.211-213
    • /
    • 2019
  • This paper proposes an image detection method, which can detect images regardless of the location and the direction of an image, required for automatic inspection based on machine vision technologies. A cable harness is considered in this paper as an inspection object, and implementation results of a technology of being applicable to a real cable harness production process is presented.

  • PDF

Comparison of Results between Tuberculin Skin Test and QuantiFERON®-TB In-Tube Assay for Diagnosis of Latent Tuberculosis Infection in Children and Adolescents (소아청소년에서의 잠복결핵감염 진단을 위한 결핵 피부반응검사와 QuantiFERON®-TB Gold In-Tube 검사와의 결과 비교)

  • Choi, Jong-Won;Kim, Min-Sung;Kim, Jong-Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.20 no.1
    • /
    • pp.17-27
    • /
    • 2013
  • Purpose: Recently, two tests are commercially available for the identification of latent tuberculosis infection (LTBI): tuberculin skin test (TST) and interferon-${\gamma}$ release assay (IGRA). Due to its false positiveness, TST tends to be preferred by IGRA until now. In our study, we simultaneously performed both TST and QuantiFERON$^{(R)}$-TB Gold In-Tube (QFT-GIT) and compared their results. Methods: TST and QFT-GIT were done for the diagnosis of LTBI among children who visited pediatric out-patient clinic at St. Vincent's Hospital, The Catholic University of Korea from February of 2007 to May of 2008. The study group was stratified into two groups in terms of whether there was intrafamilial contact or not. Results: Out of total 35 children, 29 were tuberculosis (TB)-exposed cases and the remainders were diagnosed as clinical pulmonary TB. Among these 29 children, TST was positive 38.9% (7/18) for the intrafamilial and 45.5% (5/11) for the nonintrafamilial, and at the same time, the result for QFT-GIT was positive 5.6% (1/18) and 9.1% (1/11), respectively which implies that TST was more sensitive than QFT-GIT. Among 29 TB-exposed cases, 26 initially went through TST and QFTGIT together on their first visit to out-patient clinic, and 15 continued the follow-up tests. Out of total 41 cases collected, the agreement (known as kappa value) was 0.063 which was relatively low. Including 6 cases with pulmonary TB who were all positive for TST and only 5 being positive for QFT-GIT, the final kappa value was 0.334. Conclusion: In our study, the agreement for TST and QFT-GIT was low, and the majorities were almost the cases of positive TST. In current situation with lacking a gold standard test and limited data on children to adolescents, this result is quite alarming that the recent trend tends to replace TST by QFT-GIT when diagnosing LTBI.

  • PDF