• Title/Summary/Keyword: 건축물 화재안전

Search Result 300, Processing Time 0.029 seconds

A Study on Minimum Separation Distance for Aboveground High-pressure Natural Gas Pipelines (지상 고압 천연가스 배관의 최소 이격거리 기준에 관한 연구)

  • Lee, Jin-Han;Jo, Young-Do
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.225-231
    • /
    • 2019
  • In Korea, the minimum separation distance between aboveground high-pressure natural gas pipeline and buildings is regulated by Korea gas safety (KGS) code. In this paper, The technical backgrounds for the revision of the KGS code related to the minimum separation distance was presented. A consequence-based approach was adopted to determine the minimum separation distance by a reasonable accident scenario, which was a jet fire caused by the rupture of one inch branch line attached the gas pipeline. Where, the higher thermal radiation flux threshold was selected for workers in industrial area than for people in non-industrial area, because the workers in industrial area were able to escape in a shorter time than the people in public. As result of consequence analysis for the accident scenario, we suggested the KGS code revision that the minimum separation distances between high-pressure natural gas pipeline installed above ground and buildings should be 30 meter in non-industrial area and 15 meter in industrial area. The revised code was accepted by the committee of the KGS code and now in effect.

A Study on Performance-Based Design Enforcement (성능위주설계 시행의 개선방안)

  • Lee, Yang-Ju;Ko, Kyoung-Chan;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.68-73
    • /
    • 2012
  • Performance-based design (PBD) for large scale high rise buildings has been enforced to secure fire and evacuation safety since July 1, 2011. As various types of trial and error were expected in the early stage, to suggest solutions to the problems that might be followed by the enforcement, the regulations on PBD were reviewed and a questionnaire survey to fire protection specialists was carried out. It was confirmed that PBD is required for large scale apartment buildings, and specific and detail criteria for PBD methodology and evaluations, education for PBD to personnel who design and evaluate are also in need.

A Legal Alternative for Effective Application of Pressurized Smoke Control System to Provide ′Smoke-free′ Access for Escape Shafts Used in High-Rise Building (국내 고층건물의 피난성능확보를 위한 급기가압방연(제연) 시스템의 제도개선연구)

  • 박형주;김상욱
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.49-56
    • /
    • 2001
  • There have been the current controversy over effectiveness of the pressurized smoke control systems, which are installed within escape shaft to provide 'smoke-free' access for escaping peoples. Therefore, many effective measures were given in this paper by means of the production of a design guide for various types of escape routes used in domestic buildings. The solutions were established on basis of both an investigating current door closing device application in existing facilities and global standardization for pressurized smoke control system, especially in British Standard. Finally, the design guidance for open door air velocity with introduction to three door protection clauses was presented on the basis of consideration of the safety and economical factor,

  • PDF

An Experimental Investigation on Combustion Characteristics of the Knockdown Building (조립식 건축물의 화재특성연구)

  • Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

Assessment of Fire Evacuation Safety for Building Construction (건축물 건설공사시 화재피난안전성 평가에 관한 연구)

  • Jeong, Myeong-Jin;Lee, Myeong-Gu;Ham, Eun-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.119-124
    • /
    • 2014
  • Recently buildings are constructed in larger and higher scales and becoming more complex. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore this study is aimed to assess of evacuation safety for building construction by use of simulation. On this study, the evacuation times required were estimated for the permissible evacuation times in cases. Fire safety management plans were suggested for building construction.

A Study on the Evacuation Plans of Multi Complex Building in Korea - A Focusing on fire Cases in the agora - (건축물의 다중이용시설 피난계획에 관한 연구 - 집회장 화재사례 중심으로 -)

  • Lee, Jung-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.433-444
    • /
    • 2011
  • In this study, the war has caused a huge scandal at home and abroad caused a fire in the agora, theoretical considerations and issues through case studies to identify and consequent evacuation plan is to undertake. Many a rally in a swarm of fire in the agora can cause a big disaster, focusing on the multi complex building for the evacuation area with a logical review of current and upcoming taller industrial society to cope with future activities, the nature of the fire prevention activities is to ensure the safety of the lives.

  • PDF

A Study on Fire Risk Analysis & Indexing of Buildings (건축물의 화재위험의 분석과 지수화에 관한 연구)

  • Chung, Eui-Soo;Yang, Kwang-Mo;Ha, Jeong-Ho;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.93-104
    • /
    • 2008
  • A successful fire risk assessment is depends on identification of risk, the analytical process of potential risk, on estimation of likelihood and the width and depth of consequence. Take the influence on enterprise into consideration, Fire risk assessment could carry out along the evaluation of the risk importance, the risk level and the risk acceptance. A large part of the limitation of choosing the risk assessment techniques impose restrictions on expense and time. If it is unnecessary high level risk assessment or Probabilistic Risk Assessment of buildings, in compliance with the Relative Ranking Method, Fire risk indexing and assessing is possible. As working-level technique, AHP method is useful with practical technique.

Review on Prior Evaluation for Terrorism Risk of High-rise Buildings (초고층건축물의 테러 위험도 사전평가에 관한 연구)

  • Seong, Bin;Lee, Yoon-Ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.293-316
    • /
    • 2013
  • Today's high-rise buildings are increasing concern about the safety and evacuation of people related to the fire and threat from outside. Terrorism breaking out in high-rise buildings, a symbol of the national economy results in a number of casualties, economic loss, social fear and damage to national status. That's why high-rise building has also emerged as a target of major terrorist attacks, compared to other types of buildings. We have 54 high-rise buildings in 15 regions over the country. The Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government have offered the guidelines to prevent terrorist attacks toward high-rise buildings. Since the 9/11 terrorist attacks, the U.S. Federal Emergency Management Agency (FEMA) has developed and taken advantage of the Risk Management Manual Series. According to this manual, pre-assessment is conducted for the prevention of terrorism and particularly in FEMA 455, risk of the surrounding areas, vulnerability, possibility from terrorist attacks are checked. After the check, experts classify the risk of terrorist attacks toward the high-rise buildings and according to the risk classification, architects, security experts and structure engineers can carry out terrorism prevention program for high-rise buildings. The U.K. NaCTSO has also offered the terrorism prevention guidelines. Therefore, the Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government should make more concrete guidelines for high-rise buildings such as what U.S. FEMA and U.K. NaCTSO implement, including prior evaluation technique for terrorism risk.

  • PDF

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

Fire Safety Analysis of Fire Suppression System for Aircraft Maintenance Hangar Using Fault Tree Method (Fault Tree를 활용한 항공기 격납고 소화시스템의 화재 안전성 분석)

  • Lee, Jong-Guk
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.67-73
    • /
    • 2017
  • An aircraft maintenance hangar is a building that stores, maintains, and inspects expensive aircraft. The frequency of fire occurrence is low, but the resulting human and material damage can be very serious. Therefore, in this study, we conducted a qualitative analysis of the fire safety of the currently operating fire suppression systems for aircraft maintenance hangars using the Fault Tree method, and then performed a quantitative analysis using the failure rate data for the derived basic events and analyzed the importance of the minimal cut sets. As a result of the qualitative analysis by the minimal cut set, it was found that there were 14 accident paths that could be expanded to a large fire, due to the fire control failure of the aircraft hangar fire suppression system. The quantitative analysis revealed that, the probability of the fire expanding into a large one is $2.08{\times}E-05/day$. The analysis of the importance of the minimal cut set shows that four minimal cut sets, namely the fire detector and foam head action according to the zone and blocking of the foam by the aircraft wing and the fire plume, had the same likelihood of causing the fire to develop into a large one, viz. 24.95% each, which together forms the majority of the likelihood. It was confirmed for the first time by fault tree method that the fire suppression system of aircraft maintenance hangars is not suitable for fires under the aircraft wings and needs to be improved.