• Title/Summary/Keyword: 건축면적

Search Result 517, Processing Time 0.024 seconds

Comparison of National Standards for Blast Furnace Slag and Fly Ash between Korea and China (한국과 중국간의 고로슬래그 미분말 및 플라이 애시의 품질 규정 비교)

  • Hu, Yun-Yao;Lim, Gun-Su;kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.63-64
    • /
    • 2022
  • In this study, the quality of mineral admixture, Comparison of blast-furnace slag(BS) and fly ash(FA)in Korea and China. In the case of BS, Korea is mainly classified into 1 type to 4 types according to the specific surface area, whereas China is classified into S105, 95, and 75 according to the activity index of 28 days of age. In the case of FA, Korea is like BS, is mainly classified into types 1 to 4 according to specific surface area, whereas China is classified into F, C (class F, class C) by ingredients and class I, II, and III according to powder and ignition loss.

  • PDF

Establishment of a Estimation Model of On-Road and Off-Road Parking Demand Based on the Total Floor Area of Buildings (건축물 연면적에 따른 노상·노외 주차수요 산정 모형 구축)

  • Je mo Nam;Young woo Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.2
    • /
    • pp.44-53
    • /
    • 2023
  • Recently, serious parking problems are occurring due to the difficulty of securing sufficient parking space, and it may lead to other traffic or social problems. In order to solve the parking problem in areas and districts beyond a certain range, a study on-roads and off-street parking lots reflecting regional characteristics is necessary. Therefore, this study establishing a parking demand calculation model for use as a basic study in establishing on-road and off-road characteristics. In order to conduct the study, Dong-fu, Daegu Metropolitan City was divided into dongs, and parking facilities and parking demand were investigated. The survey time was divided into daytime and nighttime on weekdays, and the types of vehicles were divided into three types: passenger car, small trucks and buses, large trucks and buses. As explanatory variables for calculating parking demand, the total floor area of buildings for each of six purposes was used, including detached houses, apartment houses, neighborhood living facilities, cultural and assembly facilities, business facilities, and sales facilities. As a result of the correlation analysis, among the six explanatory variables, the total area of neighborhood living facilities showed a significant correlation with on- and off-street parking demand. A regression analysis model was constructed using the total area of neighborhood living facilities as an explanatory variable, and statistically significant results were obtained.

A Study on the Performance Increase in Building Energy Technology according to the Korea's Zero Energy Building Policy (한국의 제로에너지건축 정책 추진에 따른 건축물 에너지기술 성능 연구)

  • Shim, Hong-Souk;Lee, Sungjoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.543-553
    • /
    • 2021
  • As a key policy for achieving the goal of reducing GHG in the building sector, Korea has enforced the mandatory certification of zero-energy buildings for new buildings in the public sector from 2020. This study evaluated a policy to achieve Net Zero by identifying the trend of changes in building energy performance according to policy and presenting a methodology to analyze the current performance state of energy technology applied to buildings. The final goal was to help stakeholders apply appropriate energy technologies for new buildings. For this study, data collected on building energy efficiency certification over the last four years have shown a gradual increase in energy performance. In addition, K-means cluster analysis was used to analyze the performance status of energy technologies applied to buildings. The high and low clusters of education and office facilities were used to analyze the comparative group (2016-2020, 2020). As a result, the solar module area in both high and low clusters of education facilities increased by 261.1% and 283.5%. In contrast, the solar module area decreased by both high and low clusters of office facilities. The most passive and active technologies showed an increase in energy performance.

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.

현대산업개발 용산 민자역사 현장

  • Lee, Seung-Gu;Kim, Byung-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.58-63
    • /
    • 2004
  • 용산민자역사현장은 용산 역세권개발 21만평 개발사업중 1단계로 연면적 82,356평의 대규모 민자역사 건설 및 복합상업시설을 신축하는 공사입니다. 용산역은 국철, 경의선, 경부선 등이 통과하고, 향후 고속철도 및 경의선의 출발역으로 기능을 담당하며, 복합상업시설에는 전자점, 영화관, 할인점, 전문점등이 있으며 2000년 10월 착공 2005.9 준공 예정이며, FAST TRACK으로 공사를 진행하고 있는 현장입니다.(중략)

Estimation Method of the Amount of Demolition Waste through Automated Calculation of Volumetric Spaces using Drones (드론 활용 체적산출 자동화를 통한 해체 폐기물량 예측기법에 관한 연구)

  • Ryu, Jung-Rim;Kim, Hye-Ri;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.681-688
    • /
    • 2022
  • In this study, the process of drone photography, automatic volume calculation, total floor area conversion, and waste calculation was constructed as a QGIS plug-in to predict the demolition waste (DW) generated in an aged area where drawing information or building information is uncertain. Through a case study, the high consistency between the automatically calculated volume using the drone and the BIM volume based on the field measurement was confirmed. Field application was carried out for the planned demolition work site, and the consistency between the drone-based volume and the actual measurement-BIM-based volume was reconfirmed. The waste generation unit was applied and the amount of DW was calculated by setting the floor height and building type, and the entire process was completed within 6 hours. Although the difference between building information and building objects through drones occurred according to the setting of temporary structures, loads, and floor heights, it was found that the actual amount of DW was generated more than the initial estimate. It is expected that measures to improve the accuracy of volume and floor area conversion will be required through case studies in the future.

A study on the Architectural Planning of Spatial Distribution at Dental College Hospital O. P. D (치과대학병원 외래진료부문의 공간배치특성에 관한 건축계획적 연구)

  • Lee, Hee-Jin;Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.3
    • /
    • pp.53-60
    • /
    • 2006
  • The medicine development and upwardly raised standard of living brings out the increased dental needs at dental hospital OPD. The dental college hospital, follows up the raised dental needs, was subdivided by specialized dental office. And now a specialized dental office needs co-work with the other specialized dental office for special dental illness and treatment. The purpose of this study is to provide a proper area distribution and location of each specialized dental office and relationship between dental office, clinic and other department by analyzing the space, area and characteristics of dental hospital OPD. The results could be used for helping its users, of patients and dentists.

  • PDF

A Study on the Planning of the Neuroscience Center in General Hospital (종합병원 뇌신경센터 건축계획에 관한 연구 - 주요단위공간을 중심으로)

  • Yun, Woo Young;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.3
    • /
    • pp.27-40
    • /
    • 2014
  • Purpose: As the nation is becoming an aging society, there is an increasing number of the patient who has Neuroscience disease. So it is necessary to build a facility which provides specialized health care. Methods: Field surveys to facilities and analysis to the floor plan have been conducted in order to suggest adequate architectural composition to the specialized neuroscience center and the dimensions of rooms. Results: The result of this study can be summarized into six points which contain guide to how to organize the specialized neuroscience center. One of the most important things in this study is to suggest the architectural type which provides efficient collaborating system between the outpatient and angiography unit. Implications: It can be said that this paper can be useful research material when the architect tries to plan the specialized neuroscience center.

A Study on the Architectural Planning of the Nurse Station in the ward of General Hospital (종합병원 병동부 간호관계제실에 관한 건축계획적 연구)

  • Yoon, Dong-Hyun;Kim, Khil-Chae;Kim, Kwang-Moon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.1
    • /
    • pp.43-51
    • /
    • 1995
  • Nurses play a great role in the nursing unit and their behaviour should be evaluated in order to find user needs in terms of ward design of general hospital. This study aims to investigate the ways in which nurses activities and traffic occur in real behaviour setting of five general hospitals. For that purpose, intensive field survey was undertook to measure the nurses' attitudes and their activities were observed in the day time for 8 hours.

  • PDF

A Study on the Evaluation and Countermeasure of Electromagnetic Interference due to Buildings in TV Frequency Band (건축물에 의한 TV주파수대 전자파장해의 평가 및 대책에 관한 연구)

  • 박재석;김동일;박연준;이창우
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 1998
  • In this paper, we have performed a numerical calculation of the scattered electromagnetic field around the building to evaluate electromagnetic interference caused by the building in the TV frequency band. The relations between the exposed concrete area of a building wall and the magnitude of the reflected wave have been examined in the case that the electroagnetic wave absorbers partially cover the building wall. From the obtained scattered electromagnetic field, we have calculated the DU radio and the required reflection loss of the electromagnetic wave absorbers which attached on the building wall to protect TV ghost.

  • PDF