• Title/Summary/Keyword: 건축높이

Search Result 291, Processing Time 0.025 seconds

Security Interpretation of the Restriction Boundary of Building for Antiquated Tunnel using 3 Dimensional Surveying (3차원 측량에 의한 노후 터널의 건축한계 확보 해석)

  • Bae Sang-Ho;Lee Hyung-Seok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.3
    • /
    • pp.251-259
    • /
    • 2006
  • For the electrification of the existing railways, the security of the restriction boundary of building with mechanistic stability research on the antiquated tunnel must be accomplished essentially. If the tunnel don't secure its restriction boundary of building, the reconstruction based on improvement of tunnel alignment are generated and its surveying data are required. The precise surveying was conducted with the same coordinate system for three tunnels of Youngdong tramline, and the restriction boundary of building of the straight and curve section were analyzed effectively by acquiring the data of profile and cross section, profile rail-height, rail-grade, cross tunnel height, and restriction boundary of building. This study is presented for valuation data of the stability of the electrification design to construct and analyze restriction boundary of building, which compared with the drawing and its existing design using profile and cross section. After this, it is interoperable to increase the development of real-time monitoring system on the tunnel structures.

법령과 고시-건축물의 설비기준 등에 관한 규칙 개정

  • Korea Mechanical Construction Contractors Association
    • 월간 기계설비
    • /
    • no.3 s.188
    • /
    • pp.34-35
    • /
    • 2006
  • 건축법 중 건축물의 설비기준등에 관한 규칙의 일부가 지난 2월 13일 개정, 공포되었다. 이번에 개정된 주요 내용은 그동안 공동주택 및 다중이용시설의 환기설비기준이 없어 적정수준의 실내의 공기 질을 확보하지 못하여 국민건강을 해치는 등의 문제점을 개선하여 △공동주택의 필요환기 횟수를 시간당 시간당 0.7회 이상이 되도록 하고 다중이용시설 중 지하 역사의 경우 필요 환기량을 1인 기준으로 시간당 25㎡ 이상이 되도록 하는 등 건축물의 용도에 따라 환기설비기준을 정함으로써 공동주택 및 다중이용시설의 실내의 공기 질 개선을 통해 국민의 건강 증진에 기여할 것으로 기대된다. 또한 △피뢰설비의 설치기준을 강화하여 건축물의 높이가 60m 이상인 고층 건축물은 측면에 낙뢰방지시설을 설치하도록 개정함으로써 고층 건축물의 벼락 피해를 예방할 수 있을 것으로 기대된다. 본지는 건축물의 설비기준등에 관한 규칙 중 신∙구조문 대비표를 게재하오니 회원사 여러분의 많은 참고를 바란다.

  • PDF

Management Guidelines for the Height of Buildings using Urban Landscape Simulation (경관시뮬레이션을 통한 건축물 높이관리에 관한 연구)

  • Lee, Dong-Hyun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.4
    • /
    • pp.132-141
    • /
    • 2007
  • The rebuilding or redevelopment of buildings in the Readjustment Project District is generally built high-rise buildings. It sometimes makes our residential area to be uniform in height and disharmony with surrounding houses and infrastructure. Then this research examines the landscape effects of the height of buildings built using landscape simulation on hillside and level ground. We suggested that it was desirable for a land readjustment project district to be managed by District Plan and Development Density Controlled Area. In addition, a consideration for the introduction of Average Floors is needed to mitigate the uniform and disharmony with surroundings.

  • PDF

Empirical study for counting same shaped building material quantity using UAV and deep learning (딥러닝과 드론을 이용한 동일 모양 건축 자재 수량 측정에 관한 실증적 연구)

  • Moon, Ji-Hwan;Song, Nu-lee;Choi, Jae-Gab;Park, Jin-Ho;Kim, Gye-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.649-652
    • /
    • 2019
  • 최근에 카메라를 사용하여 물체를 인식하고 수량을 측정하는 연구가 진행되고 있다. 하지만 건축 자재와 같이 인접한 동일 물체의 경우, 인식과 측정이 어려우며, 이와 관련된 연구는 부족한 실정이다. 본 논문에서는 이러한 문제를 해결하기 위해 딥러닝과 드론을 사용하는 방법을 통하여 자재 더미의 윗면과 측면의 촬영, 드론 로그를 사용하한 드론 높이와 Yaw값 획득, 영상 내 자재 종류와 영역 정보 등 미리 학습된 딥러닝 모델을 사용한 획득방법, 드론 촬영 시의 Yaw값 차이를 이용해 윗면과 측면이 공통으로 가지는 직선 검색, 자재 더미의 가로, 세로, 높이의 비율 등을 통한 각 화소 비율과 자재 개수의 영역별 가상의 체적값 분석, 드론의 화각, 높이를 사용한 체적 사진측량값 획득, 가상 체적과 사진측량법 사이의 오차 최소화 비율 등을 연구하였다.

Analysis on Heat of Hydration for Height of Shell Concrete Pouring in Reactor Containment Building (원자로건물 외벽 타설 높이 산정을 위한 수화열 해석)

  • Kim, Jwa-Young;Park, Jong-Hyok;Lee, Han-Woo;Bang, Chang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.165-166
    • /
    • 2012
  • A thermal stresses by heat of hydration was analyzed according to a change of a pour height in reactor containment building. In case of more than 3.6m pouring height a crack index by heat of hydration analysis resulted in less than 1 because there is not a construction joint of vertical direction and for a self-restraint effect of circumferential section shape. Therefore detailed consideration on a mixture proportion of binder type, quantity in concrete and selection of a form in seasonal air temperature is needed for a control of tensile stress by heat of hydration.

  • PDF

A Fundamental Study of Optimization to Control on Height of Roller Shade in Office Building through Mock-up Experiment (Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.148-153
    • /
    • 2008
  • An inflow of daylight to the room offers comfortable view environment, psychological and physical security to people in the room and there are merits such as a work efficiency and energy saving. But, it has many problems as an excessive direct sunlight, cooling and heating. We can expect to have energy saving effect for illumination with comfortable view environment creation through control on height of roller shade. This study will be a used a fundamental approach to control on height of roller shade to changing daylight.

  • PDF

Bond Strength Test According to height of foot of Tile (타일 뒷발 높이에 따른 부착강도 실험)

  • Kim, Bum Soo;Seo, Hyun Jae;Choi, Eun Gyu;Lee, Jung Hun;Song, Je Young;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.283-284
    • /
    • 2018
  • The rear side surface of tiles act have protrusions that helps secure the adhesion between the tile and the mortar for tile setting. Conventional height of the rear side usually ranges between 1 to 1.5 mm, and the molding method is classified in between press type and compression type during the manufacturing process, with most tiles being produced by the former method. In sites where adhesion failures were observed, tiles were taken to examine the cause of defect. It was determined that height was irregular at the rear side surface. Based on these findings, an experiment was conducted to determine the correlation between the rear surface and the bonding strength of tiles.

  • PDF

A study on acoustical environment of classrooms (강의실 내 음환경에 관한 연구)

  • Lee Chai-Bong;Kim Yong-Man
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.501-504
    • /
    • 2002
  • 본 논문에서는 최근 건축공간에 있어서 음환경에 대한 관심이 놓아지면서 학교 건축물에 있어서 강의실내의 음환경을 측정하고, 학교건축물에 대한 음환경 기준을 확립하는 데에 기초자료와 필요한 제안을 하는 것이 목적이다. 현재 음환경 기준은 단순히 소음fp밸이나 잔향 시간과 같은 단순한 물리특성만을 기준으로 하고 있다. 여기서는 강의실 내의 잔향시간, D, STI 등외 물리지표와 설문조사 등 주관적 평가를 통해 새로운 음환경 기준을 제시하려고 한다. 여기서 사용되는 물리지표로는 TSP(Time-Streched-Pulse)신호를 사용하여 잔향시간과 D(Deutlichkeit), STI(Speech Transmission index)를 산출하였다. 강의실의 화자의 위치에서 1.5m 높이에 스피커를 놓고 청취자의 위치인 여섯 점에서 무지향성 마이크로폰을 1.2m 높이에 놓고 마이크로폰으로 들어온 임펄스 응답을 측정하고, 강의실 내의 잔향시간과 D, STI를 산출하였다. 다음에 설문조사를 실시하여, 앞에서 측정한 물리지표와 설문조사를 통해 얻은 주관적 평가와의 상관관계를 파악하였다.

  • PDF

Improvement plan for the standard for calculating the height of the stair railing for Barrier Free (BF) certification system (장애물 없는 생활환경(BF) 인증제도 계단 난간 높이 산정기준 개선안)

  • Lee, Sang-Soo;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.218-219
    • /
    • 2022
  • Among the Barrier Free (BF) certification evaluation items for public facilities, at which position the standard for the effective height of the stair railing handle should be calculated is not clearly determined. Because of this, not only the evaluation standards of the certification authority and the evaluation committee are different, but disputes are occurring between the ordering organization, the design company, and the construction company. Therefore, the stair railing installation standard laws for public facilities were analyzed and through a case study of institutions that obtained the BF certification, problems were analyzed. The results of problem analysis reveal the following. 1) The standards of the Ministry of Health and Welfare and the Ministry of Land, Infrastructure, and Transport were different. 2) The effective height calculation standard was ambiguous, and disputes occurred frequently. To solve this problem, we proposed improvement plans for calculating the height of the stair railing that can comply with laws while ensuring safety.

  • PDF

Digital Technologies for Structural System Design of Irregular Shaped Buildings (비정형 건축물 구조시스템 설계를 위한 디지털 요소기술)

  • Lee, Jae-Cheol
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.76-79
    • /
    • 2009
  • 최근 계획되고 있는 초고층 건축물은 높이에 따른 기술경쟁력의 과시와 함께 비정형의 자유로운 건축적 형상을 통한 디자인 형태의 상징성을 강조하는 경향을 보이고 있다. 이러한 비정형 건축물의 구조시스템은 기술적, 경제적 문제로 인해 한정된 수의 가능성 있는 대안만이 고려되어 왔으나, 첨단 디지털 기술의 발전에 따라 비정형 건축물의 구조시스템에 대해 이전에는 적용이 불가능하였던 다수의 구조시스템 대안을 생성하고 동일한 컨셉을 가진 다양한 구조시스템 대안의 비교평가를 통해 검토안의 수를 최소화하는 것이 가능해졌다. 본 연구에서는 비정형 건축물 구조시스템 설계를 위한 디지털 요소기술에 대해 현재까지의 연구현황을 분석하고 앞으로의 연구방향과 과제를 제시하고자 한다.

  • PDF