• Title/Summary/Keyword: 건식 주입

Search Result 39, Processing Time 0.029 seconds

A study on the NO oxidation using dry oxidant produced by the catalytic conversion of H2O2 (H2O2 촉매 전환에 의해 생성된 건식산화제를 이용한 NO 산화에 관한 연구)

  • Jang, Jung Hee;Han, Gi Bo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 2016
  • In this study, the NO oxidation using dry oxidant produced by catalytic $H_2O_2$ conversion was conducted. It was shown that Mn-based $Fe_2O_3$ support catalyst has the best performance in the catalytic $H_2O_2$ conversion and its combined-NO oxidation. The reaction characteristics of NO oxidation was investigated by the various operation conditions such as $H_2O_2$ amount, oxidation temperature and space velocity. As a results, the oxidation efficiency of NO greatly depends on the oxidation reaction temperature, $H_2O_2$ amount and space velocity. The performance of NO oxidation was increased with increasing the oxidation temperature and $H_2O_2$ amount. Also, the performance of NO oxidation was decreased with increasing the space velocity.

Fabrication Enhancement of Hollow-type Silicon Microneedle Array for Transdermal Drug Delivery (경피 약물 전달을 위한 Hollow형 실리콘 미세바늘 어레이의 제작 공정 개선)

  • Kim, Seung-Kook;Chang, Jong-Hyeon;Kim, Byoung-Min;Yang, Sang-Sik;Hwang, In-Sik;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1532-1533
    • /
    • 2007
  • Hollow형 미세바늘 어레이는 주사기와 패치의 장점을 결합하여 여러 종류의 약물을 통증 없이, 전달할 수 있게 한다. 본 논문에서는 건식 식각 방법과 습식 식각 방법을 이용하여 hollow형 실리콘 미세바늘 어레이를 제작하는 제작 공정과 그 결과를 제시하였다. 미세바늘 어레이의 형태는 실리콘 웨이퍼의 앞면에서 세 번의 식각 공정을 이용해 제작되었는데, 첫 번째 건식 식각 공정으로 피부에의 침투를 원활히 하기 위해 바늘 끝을 형성하고, 두 번째 건식 식각 공정으로 바늘의 길이를 조절하며, 마지막 HNA solution을 이용한 습식 식각 공정으로 바늘을 더 가늘게 만들면서 끝을 더 날카롭게 식각한다. 바늘을 통해 약물전달이 가능하도록 웨이퍼의 뒷면으로부터 건식 식각 공정을 이용해 약물 주입통로를 형성하였다. 제작된 Hollow형 실리콘 미세바늘 어레이는 $170\;{\mu}m$의 너비와 $230\;{\mu}m$의 길이, 직경 $40\;{\mu}m$의 약물 주입통로를 가지고 있으며, $1\;cm^2$의 시편 위에 $1000\;{\mu}m$의 피치로 $9{\times}9$ 개의 바늘을 형성하였다.

  • PDF

Continuous Mesophilic-Dry Anaerobic Digestion of Organic Solid Waste (유기성고형폐기물의 연속 중온 건식혐기성소화)

  • Oh, Sae-Eun;Lee, Mo-Kwon;Kim, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.341-345
    • /
    • 2009
  • Continuous dry anaerobic digestion of organic solid wastes (30% TS, Total Solids) comprised of food waste and paper was performed under mesophilic condition. During the operation, hydraulic retention time (HRT) was decreased as follows: 150 d, 100 d, 60 d, and 40 d, which corresponded to the solid loading rate of 2.0, 3.0, 5.0, and 7.5 kg TS/$m^3$/d, respectively. Volumetric biogas production rate ($m^3$/$m^3$/d) increased as HRT decreased, and the highest biogas production rate of 3.49${\pm}$0.31 $m^3$/$m^3$/d was achieved at 40 d of HRT. At this HRT, high volatile solids (VS) reduction of 76% was maintained, and methane production yield of 0.25 $m^3$/kg $TS_{added}$ was achieved, indicating 67.4% conversion of organic solid waste to bioenergy. The highest biogas production yield of 0.52 $m^3$/kg $TS_{added}$ was achieved at 100 d of HRT, but it did not change much with respect to HRT. For the ease feed pumping, some amount of digester sludge was recycled and mixed with fresh feed to decrease the solid content. Recirculation volume of 5Q was found to be the optimal in this experimental condition. Specific methanogenic activity (SMA) of microorganisms at mesophilic-dry condition was 2.66, 1.94, and 1.20 mL $CH_4$/g VS/d using acetate, butyrate, and propionate as a substrate, respectively.

Gasification Performance in the Dry-Feeding Gasifier with Variation of Feed Ingredients and Main Operational Problems (건식 가스화기 시료의 선정인자 및 변화에 따른 가스화 특성과 주요 운전상 문제점)

  • 윤용승;정석우;김원배
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.90-104
    • /
    • 2001
  • 일일 최대 석탄처리 용략이 3톤인 건식 석탄가스화기를 사용하여 가스화에 미치는 주요 변수들중 산화제내 산소농도와 증기 주입량을 변경시켜 가스화성능을 조사하였고, IGCC용 대성석탄을 선정하는 입장에서의 주요 인자 및 고온고압 조건에서의 가스화기 운전상 특성과 문제점을 파악하여 운전상 문제에 대한 대책을 제시하였다. 사용한 석탄은 유연탄인 중국 대동탄과 아영청탄인 미국 알라스카의 유시벨리탄에었는데, 두 탄중 모두 건식 가스화기의 운전상에는 문제가 없었다. 가스화를 위한 산소의 농도는 90%까지 그리고 석탄시료 무게 대비 증가량 10∼12%까지는 가스화의 온도 유지와 가스조성 측면에서 무리 없이 적용할 수 있다고 판단되었다. 이들 가스화 시험을 통하여 생성된 슬랙은 가스화기 슬랙탭의 조업 온도와 대상석탄 회재의 용융특성에 따라 침상 또는 알갱이 형태로 배출되었으며, 슬랙으로부터 중금속 성분이 유출되는지를 분석해 본 결과 침출수에 의한 2차 오염은 없는 것으로 확인하였다. IGCC용 석탄을 선정하는 석탄특성에서는 미분탄의 수분함량, 회재함량, 회재용융온도, 발열량 측면에서 검토하였는데, 건식가스화기의 경우 미분탄의 표면수분의 제거가 중요하고 회재의 함량과 회재의 용융온도를 같이 고려하여 적정한 시료 석탄이 선정되어야 한다는 결론을 얻었다. 가스화기 운전측면에서는 여러 기계적인 문제점들이 발견되었는데 시료공급노즐의 막힘문제, 역화문제, 고온가스 누출문제, 추운 겨울 운전시 오링(O-ring)문제 등에 대한 논의와 대책을 제시하였다.

  • PDF

Nitrogen-Doping of Nano-Thin Exfoliated (NTE) Graphite by RF Thermal Plasma with NH3

  • Lee, Gyu-Hang;Sin, Myeong-Seon;Choe, Seon-Yong;Jo, Gwang-Seop;Kim, Seong-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.233.1-233.1
    • /
    • 2016
  • 화학적 방법에 의한 NTE graphite의 박리 또는 전도도 개선을 위한 도핑공정을 수행할 경우, 결함 및 불순물 생성에 의해 재결정화 공정 및 순도 개선을 위한 별도의 공정을 필요로한다. 본 연구에서는 건식 방법으로써 10,000K 이상의 초고온 RF 열플라즈마를 이용하여 in-situ 방법으로 흑연의 박리, 결함 제거, 결정성 향상 및 도핑 공정을 수행하고, 도핑특성을 평가하였다. 질소 도핑을 위하여 암모니아 가스를 첨가하여 NTE graphite를 도핑 처리하였으며, 시뮬레이션을 통하여 반응기 내부의 온도분포를 파악하고, 도핑을 위한 암모니아가스가 분해되어 도핑공정이 수행될 수 있는 투입위치를 결정하였다. 질소 도핑율은 암모니아 가스의 주입위치에서의 온도 및 가스 주입 유량 등의 공정조건에 따라 변화됨을 확인하였고, XPS 분석결과 최대 14.87 atomic%의 도핑율의 결과를 얻었다.

  • PDF

Implementation of DS/SS(FM-DS/SS) system using FM (FM을 이용한 DS/SS(FM-DS/SS) 시스템의 구현)

  • 정명덕;박지언;변건식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.98-107
    • /
    • 1998
  • For implementation of FM-DS/SS system. This paper has analyzed SO(Synchronous Oscillator) being oscillated by the motivation of injected signal. Transmitter has adopted FM-DS/SS modulation method using RF output-signal of FM. Receiver is used SO to demodulation of FM-DS/SS and applied sliding correlator for synchronization of PN clock. As a result of the inspection, SO presented stable lock ability in spite of doppler apperance and proved the synchronous properties of it in the FM-DS/SS system.

  • PDF

Optimization and Application of Si-DLC Coating with Low Friction and High Hardness Property by Using PECVD Method

  • Yeo, Gi-Ho;Mun, Jong-Cheol;Sin, Ui-Cheol;Lee, Hyeon-Seok;Choe, Sun-Ok;Yu, Jae-Mu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.169.2-169.2
    • /
    • 2013
  • 본 연구에서는 gas를 이용한 PECVD 공법중 이온화 에너지가 높고 대면적 코팅이 용이한 Hybrid 코팅 장비에서 Linear Ion-Gun 이용하여 탄화수소 계열의 gas인 $C_2H_2$ 와 Si을 함유한 TMS (tetramethylsilane, $Si(CH_3)_4)$ gas를 이용하여 저마찰, 고경도 특성을 갖는 Si-DLC 코팅에 대한 연구를 수행하였다. Si-DLC 코팅에 앞서 전처리 공정으로 Linear Ion-Gun에 Ar gas를 주입하고 고전압의 DC 전원을 인가하여 제품 표면의 건식세정 및 표면 활성화를 진행 후, $C_2H_2$ 와 TMS gas를 Linear Ion-Gun에 주입하여 Si-DLC 코팅 공정을 진행하였다. Si-DLC 코팅시 $C_2H_2$ gas 주입량을 고정하고 TMS 가스 유량을 5~20sccm으로 조절하여 Si 함유량에 따른 Si-DLC 코팅막의 특성을 분석하였다. 이렇게 코팅된 Si-DLC의 박막 특성 분석으로 마찰계수 측정을 위해 ball-on-disk 타입의 tribometer를 사용하였으며, 박막 경도 측정은 Nano-indenter를 이용하여 분석을 진행하였다. 그 결과 Si을 포함하지 않는 DLC의 경우 마찰계수가 ~0.2를 가지는 반면, Si-DLC의 경우 Si 함유량이 약 1.5at%일 때, 마찰계수 ~0.04 저마찰의 우수한 특성을 지니며, 박막의 경도는 22[Gpa]로 고경도의 Si-DLC 코팅을 확인할 수 있었다.

  • PDF

Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure (젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구)

  • Kang, Ho;Kim, Sun-Woo;Jeong, Ji-Hyun;Ahn, Hee-Kwon;Jung, Kwang-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.12
    • /
    • pp.696-704
    • /
    • 2015
  • This study was carried out to evaluate the optimum operational condition of Semi-continuously Fed and Mixed Reactor (SCFMR) to treat the dairy cow manure and saw dust mixture. Step-wise increase in organic loading rates (OLRs) or decrease in hydraulic retention times (HRTs) were utilized until the biogas volume became significantly decreased at mesophilic temperature ($35^{\circ}C$). The optimum operating condition of the SCFMR fed with TS 13% dairy cow manure and saw dust mixture was found to be an HRTs of 25 days and its corresponding OLRs of $4.45kg\;VS/m^3-day$. At this condition the biogas and methane production rates were 1.44 v/v-d and 1.12 v/v-d (volume of biogas per volume of reactor per day), respectively and the TVS removal efficiency of 37% was achieved. The successful operation with such a high OLR was due to the high reactor alkalinity concentration of 14,500~15,600 mg/L as $CaCO_3$ as a result of the characteristic of the original substrate, dairy cow manure and saw dust mixture whose alkalinity was more than 8,000 mg/L as $CaCO_3$. The parameters for the reactor stability, the ratios of volatile acids and alkalinity concentrations (V/A) and the ratio of propionic acid and acetic acid concentrations (P/A) appeared to be 0.11 and 0.43, respectively, that were greatly stable in operation. Free ammonia toxicity was not experienced due to the long term acclimation by the reactor TS content ranged 7.2~10.4% during the entire operational period.

Removal of HCl Using a Bag-Filter with Addition of Bicarbonate (중탄산나트륨이 첨가된 여과집진기를 이용한 염화수소의 제거)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.3
    • /
    • pp.121-128
    • /
    • 2007
  • The purpose of this study was to investigate the removal efficiencies of HCl in dry reactor and Bag-Filter system. The bicarbonate was used as adsorbent to measure the HCl removal rate. The performance of bicarbonate was evaluated to investigate the removal efficiency. It was analysed that the best operation condition in using bicarbonate in process. The operating parameters was residence time, stoichiometric ratio, temperature and pressure. The Residence time was 1.5 sec, stoichiometric ratio was 1SR, 1.25SR, temperature was $160^{\circ}C$, $180^{\circ}C$, $200^{\circ}C$ and the bag filter pressure was 210mmAq, 230mmAq, 250mmAq. In this study it was found that the stoichiometric ratio and pressure can be effected in removal of HCl however the removal efficiency do not depends on temperature. The best operating condition was on 1SR, 230mmAq and $180^{\circ}C$ respectively and in this condition the best removal rate was 99.50%.

  • PDF