• Title/Summary/Keyword: 거울 실험

Search Result 108, Processing Time 0.032 seconds

박막 변형거울(Membrane Deformable Mirror)을 이용한 파면 보정에 관한 연구

  • Na, Ja-Kyung;Ko, Do-Kyung;Lee, Yu;Cha, Byeong-Heon
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.04a
    • /
    • pp.32-32
    • /
    • 2004
  • 변형거울은 적응광학계(Adaptive Optics System)에서 파면 측정 센서와 더불어 중요한 장치로서 왜곡된 파면을 보정하는 역할을 한다. 이 실험에서는 저가의 박막 변형거울을 이용한 파면 보정 방법을 연구하였다. 박막거울의 변형은 알루미늄으로 코팅된 박막과 37개의 제어 전극에 각각 바이어스 전압과 제어전압을 가함으로서 이루어졌다. 박막거울에서 나타나는 바이어스 전압에 의한 경면의 초기 오목 변형은 수동 변형 거울 (MDM)을 사용해서 0.1 wave 이내로 보정할 수 있었다. (중략)

  • PDF

The Effect of Mirroring Environment on the Attitude of Client in Counselling (상담 시 거울 환경이 내담자 태도에 미치는 영향)

  • Kim, Mi-So;Seo, Seon-Yeong;Lee, Eun-Sol;Jeon, Na-Hyeon;Jo, A-Hae;Kim, Eun-Joo
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.427-431
    • /
    • 2019
  • The purpose of this study was to investigate whether the mirror environment influences the attitude of the client when counselling. A group of 16 experimenters, 16 controls, a group with a mirror environment, and 32 men and women according to the presence or absence of interventional mirror environments in the control group. There was a statistically significant difference in the 'self - alienation' factor of the Authentic Scale(AS) in the experimental group that provided the mirror environment. There was no significant difference in the Semantic Differential Scale(SDS) between the experimental group and the control group. This study was conducted to investigate whether the presence of the mirror environment affects the client 's authenticity. There were significant differences in some of the factors of the Authentic Scale.

Camera Calibration Method for Vision Systems with Mirror Reflector (반사거울을 포함한 비젼시스템의 카메라 보정 방법)

  • Lee, Wan-Young;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.294-295
    • /
    • 2008
  • 본 논문에서는 검사 및 측정용 비젼 시스템에서 카메라와 평면거울을 이용하여 영상을 촬영할 패 발생하는 왜곡의 보정 방법을 제안한다. 빛이 거울과 카메라 사이를 통과할 때 거울 위치의 틀어짐으로 인하여 직진성을 보장받기 어렵다. 이러한 문제점을 해결하기 위하여 왜곡 영상에 대한 모델을 구하고 이를 해결하는 방법을 제시한다. 거울의 위치의 틀어짐은 영상 촬영시 일그러진 사각형 형태로 왜곡이 나타난다. 이 특성을 이용하여 사각형 형태의 실험 대상체를 생성하여 이를 촬영하고 왜곡의 정도를 측정하여 평면거울의 보상값을 구한다. 이 방법으로 평면거울의 자세를 보정하여 왜곡되지 않은 영상을 얻을 수 있다.

  • PDF

Application Experiment of Mirror Sunlighting System to House (반사거울형 태양광채광시스템의 주택적용 실험)

  • Jeong, In-Young;Kim, Jeong-Tai
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.57-60
    • /
    • 2005
  • 자연채광은 실내공간의 쾌적성을 향상시키며, 재실자의 건강을 증진시킬 뿐만 아니라 에너지 절약적인 측면에서 시너지 효과를 발휘하고 있다. 이에 반사거울형 태양광채광시스템은 도시가 과밀하고 고층화됨에 따라 자연채광의 도입이 어려운 실내공간에 태양광을 도입할 수 있는 자연에너지 활용장치라 할 수 있다. 본 연구는 태양광채광시스템을 이용하여 주거건물 옥상에 1차반사거울을 설치하고, 반지하의 상부에 2차반사거울을 설치하여 거실공간에 태양광을 유입하였다. 시스템 미설치시와 설치시에 대한 거실의 바닥면조도와 외부조도를 동시에 측정하여 외부조도에 대한 내부조도의 비율인 주광조도비를 분석하고, 증감율을 구하여 반사거울형 태양광채광시스템의 성능을 평가하였다. 채광성능평가 결과 채광시스템의 설치로 인한 실내 주광조도비는 평균 $80{\sim}1,400%$정도 증가하는 것으로 나타났으며, 또한 창면부에 비해 실의 후면부가 2배 이상 증가한 것으로 나타나 채광성능이 매우 큰 것으로 나타났다. 따라서 본 연구에서 실험한 반사거울형 태양광 채광시스템은 주거건물에서의 적용이 용이하고 높은 채광성능을 제공할 수 있어 실내 빛환경 향상에 크게 기여할 수 있을 것으로 기대된다.

  • PDF

Fiber optic circular polarizing mirror using polymer cholesteric liquid crystal and it's application in the mode-locked fiber laser (콜레스테릭 액정 폴리머 박막을 이용한 광섬유 원편광 거울 제작 및 이를 이용한 모드 록킹 된 광섬유 레이저)

  • 장도일;김경헌;김인선;김성태
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2000
  • We propose a novel in-line fiber optic circular polarizing mirror utilizing cholesteric lIquid crystal (CLC) polymer [11m for the fiber laser applications. Ions matrix representation of this device has been derived and venfied experimentally. In a Fabry-Perot cavity configuration, a CLC fiber optic rmrror has been used to achieve longitudinal mode suppression as well as to obtain passively mode~locked laser operations with 630 fs laser pulses via nonlinear polarization evoluhon.oluhon.

  • PDF

The Effects of Convergent Stimulation on tDCS during Mirror Therapy to Improve the Muscle Strength and Gait Ability in Chronic Stroke Patients (만성 뇌졸중 환자에서 거울 치료 시 tDCS의 융합 자극이 다리근력 및 보행능력에 미치는 효과)

  • Lee, Seung-Tae;Kim, Kyung-Yoon
    • Journal of Industrial Convergence
    • /
    • v.18 no.4
    • /
    • pp.51-59
    • /
    • 2020
  • The purpose of this study was to investigate the improvement of muscle strength and gait ability of paralyzed lower extremity through convergent stimulation of tDCS(transcranial direct current stimulation) during mirror therapy with resistance exercise in chronic stroke patients. 12 patients with stroke were randomly assigned and divided into groupI(n=6) and groupII(n=6). GroupI provided NDT(neurodevelopmental treatment) and mirror therapy with sham tDCS, and groupII provided NDT and mirror therapy with tDCS. Each convergent stimulation was conducted 5 times a week, 30 minutes per session for a total of 4 weeks. All evaluation was conducted before intervention and performed after 4 weeks. Lower extremity strength showed a significant improvement in groupII compared to groupI(p<.05), and in comparison between groups by variance, significant difference in the quadriceps(p<.01) and tibialis anterior(p<.01). Gait ability showed a significant improvement in both groupI(p<.05) and groupII(p<.05), and significant difference in comparison between groups by variance(p<.01). In conclusion, mirror therapy with tDCS convergent stimulation had a positive improvement effect on paralyzed lower extremity to strength and gait ability through the overlapping interaction.

Design of Omnidirectional Mirror Using Quarter-wave Dielectric Stacks (${\lambda}_0$/4 두께 유전체 다층 박막계를 이용한 전방향 거울의 설계)

  • 김성화;황보창권
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.180-181
    • /
    • 2000
  • 일반적으로 광통신이나 고출력 레이저에 사용되는 광학 소자들 중 고반사율의 거울은 특정 파장과 특정 각도에 대해서만 민감하도록 설계되어 있다. 이것을 여러 파장의 빛을 여러 각도로 입사시키더라도 높은 반사율을 얻는다면, 소자의 효율을 향상시키는데 상당한 효과를 볼 수 있다. 은이나 알루미늄의 금속박막으로 제작되는 금속 거울은 제작하기 쉽고 입사파장과 금속의 재질에 관련되어 90 %이상의 반사율을 갖지만, 특정한 각도에서는 빛이 금속 내에 있는 자유 전자들에 의해 상당량 흡수되어 버린다. 따라서 금속 거울은 에너지의 손실이 적어야 하는 광통신이나 고출력 레이저와 같은 응용분야에는 사용될 수 없다. 이러한 흡수가 거의 없는 유전체 거울은 고굴절률과 저굴절률의 층이 λ$_{0}$/4의 광학 두께를 가지고 주기적으로 반복되는 구조를 갖는다. 이러한 λ$_{0}$/4 유전체 다층 박막계는 1-차원 photonic 결정 구조와 동일하게 다룰 수 있는데, 1-차원 photonic 결정 구조가 모든 입사각도에 대해서 전방향 반사를 보인다는 것을 이론과 실험적으로 증명하였다[1-3]. (중략)

  • PDF

Measurement of the Axial Displacement Error of a Segmented Mirror Using a Fizeau Interferometer (피조 간섭계를 이용한 단일 조각거울 광축방향 변위 오차 측정)

  • Ha-Lim, Jang;Jae-Hyuck, Choi;Jae-Bong, Song;Hagyong, Kihm
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.22-30
    • /
    • 2023
  • The use of segmented mirrors is one of the ways to make the primary mirror of a spaceborne satellite larger, where several small mirrors are combined into a large monolithic mirror. To align multiple segmented mirrors as one large mirror, there must be no discontinuity in the x, y-axis (tilt) and axial alignment error (piston) between adjacent mirrors. When the tilt and piston are removed, we can collect the light in one direction and get an expected clear image. Therefore, we need a precise wavefront sensor that can measure the alignment error of the segmented mirrors in nm scale. The tilt error can be easily detected by the point spread image of the segmented mirrors, while the piston error is hard to detect because of the absence of apparent features, but makes a downgraded image. In this paper we used an optical testing interferometer such as a Fizeau interferometer, which has various advantages when aligning the segmented mirror on the ground, and focused on measuring the axial displacement error of a segmented mirror as the basic research of measuring the piston errors between adjacent mirrors. First, we calculated the relationship between the axial displacement error of the segmented mirror and the surface defocus error of the interferometer and verified the calculated formula through experiments. Using the experimental results, we analyzed the measurement uncertainty and obtained the limitation of the Fizeau interferometer in detecting axial displacement errors.

Systematic Review on Effect of Mirror Therapy on Upper Extremity Function for Stroke Patients (뇌졸중 환자의 상지기능 향상을 위한 거울치료 효과에 관한 체계적 고찰)

  • Park, Jin-Hyuck;Heo, Seo-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.215-222
    • /
    • 2014
  • Recent years, mirror therapy or mirror neuron therapy has been used to improve neural damage of upper extremities among stroke patients. This systematic review was conducted to assess the clinical effect of mirror therapy used for the treatment of upper extremities for patients with stroke. After literature search, researchers selected for 9 randomized controlled clinical trial studies registered up to October 2013 based on PubMed database, using the following search terms: mirror therapy, mirror neuron, stroke, paresis, hemiplegia, upper extremity. There were significant improves of distal upper extremity function in the use of mirror therapy groups but the research using range of motion(ROM) as outcome measure. In conclusion, mirror therapy was more effective than conventional therapies or sham therapies for upper recovery of distal upper extremity function among stroke patients.