• Title/Summary/Keyword: 강인제어기법

Search Result 332, Processing Time 0.026 seconds

Robut DC Servo Motor Position Control System based on Acceleration Control (가속도제어에 근거한 강인한 직류서보전동기 위치제어계)

  • 박태건;이기상
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.101-110
    • /
    • 1995
  • In this paper, a DC servo motor position control system based on acceleration control is proposed. The proposed control system consists of an acceleration controller and an auto-tuqing fuzzy PID controller. The auto-tuning fuzzy PID controller provides corrections for an acceleration reference to remove the effect of parametric uncertainties. And it comprises of the expert system which performs the automatic tuning of the PID controller parameters and the conventional PID controller. Expermental results demonstrate strate thi~tth e proposed overall control system has robust properties and good control performances with regard to unmeasurable disturbances and parameter variations. Therefore, the proposed control scheme enhances the applicability of an acceleration control approach and especially performs accurate position control under such an operating environment that model uncertainties exist and/or load, etc. change significantly.

  • PDF

A Linear Feedback Method with Switched Gains to Control the Active and Reactive Powers of a Doubly Fed Induction Generator for Wind Turbines (이중여자 유도형 풍력발전기의 전력제어를 위한 스위칭 이득기반의 선형궤환제어기법)

  • Kim, Won-Sang;Sim, Gyung-Hun;Jou, Sung-Tak;Kim, Seo-Hyoung;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.88-90
    • /
    • 2008
  • 본 논문은 이중여자 유도형(DFIG) 풍력발전 시스템에서 유효전력과 무효전력을 직접적으로 제어하기 위해 가변구조제어의 일종인 스위칭 이득기반의 선형궤환(LFSG)제어기법을 제시한다. 개조된 직접전력제어기법 (DPC)과 공간벡터변조방식(SVM)은 제안하는 제어기법을 실현하기 위해 이용된다. 개조된 직접전력제어원리를 이용해서 설계된 LFSG제어기법은 널리 사용되고 있는 자속기준제어기법(FOC)에 비해서 간단한 제어구조로 강인성과 빠른 응답특성을 보인다. 시뮬레이션결과는 제안하는 제어전략의 타당성과 강인성을 확인해준다.

  • PDF

Robust speed control of DC motor using Expert Sliding mode controller (전문가 슬라이딩 모드 제어기를 이용한 직류전동기의 강인한 속도제어)

  • 지봉철;박왈서
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.89-93
    • /
    • 2000
  • Robust control for DC motor is needed according to the highest precision of industrial automation. However, when a motor control system has an effect of load disturbance, it is very difficult to guarantee the robustness of control system. Generally, it is known that sliding mode controller has robustness. But, after it is assumed that we known the disturbance uncertainty, sliding mode controller is designed. Thereafter, if we are not known th disturbance uncertainty then controller design is difficult. As a method solving this problem, in this paper, Expert sliding mode control method for motor control system is presented.The proposed controller can eliminate load disturbance effectively. The effectiveness of the control scheme is verified by simulation results.

  • PDF

Robust Current Control Scheme of a Grid-connected Inverter under Unbalanced Voltage and Grid Impedance Variation (불평형 전압과 계통 임피던스 변화에 강인한 계통연계 인버터의 전류제어 기법)

  • Kim, Hyun-Sou;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.51-52
    • /
    • 2015
  • 분산전원을 계통에 연계하여 운용하는 경우 계통연계 인버터가 사용되며 계통에 주입되는 유효전력과 무효전력의 크기를 조절하기 위해 인버터의 출력전류를 제어하게 된다. 그러나 계통전압이 불평형 상태이거나 계통 임피던스에 변동이 있을 경우 계통연계 인버터의 출력전류 제어 성능이 떨어지는 문제가 발생한다. 본 논문에서는 계통전압의 불평형 상태와 계통 임피던스 변동에 강인한 계통연계 인버터의 새로운 전류제어 기법을 제안한다. 제안된 기법은 외란관측기 기반 제어기를 사용하여 계통전압의 불평형 혹은 계통 임피던스 변화와 같은 외란의 영향을 보상한다. 제안된 기법의 강인성과 성능이 시뮬레이션을 통해 입증된다.

  • PDF

Design of Robust Fuzzy Controller for Load-Frequency Control of Power Systems Using Intelligent Digital Redesign Technique (지능형 디지털 재설계 기법을 이용한 전력 계통의 부하 주파수 제어를 위한 강인한 퍼지 제어기 설계)

  • Joo, Young-Hoon;Jeo, Sang-Won;Kwon, Oh-Sin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.4
    • /
    • pp.357-367
    • /
    • 2000
  • A new robust load-frequency control methodology is proposed for nonlinear power systems with valve position limits of the governor in the presence of parametric uncertaines. The TSK fuzzy model is adopted and formulated for fuzzy modeling of the nonlinear power system. A sufficient condition of the robust stabilitry is presented in the sense of lyapunov for the TSK model with parametric uncertainties. The intekkigent digital redesign technique for the uncertain power systems is also studied. The effectiveness of the robust digital fuzzy controller disign mothod is demonstrated through a numerical simulation.

  • PDF

Robust $H{\infty}$ Control Using Sliding Mode and LMI (슬라이딩모드와 LMI를 이용한 강인 $H{\infty}$ 제어)

  • Kim, Su-Jin;Kim, Min-Chan;Park, Seung-Kyu;Ahn, Ho-Kyun;Kwak, Gun-Pyong;Yoon, Tae-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.316-321
    • /
    • 2007
  • [ $H{\infty}$ ] controller, which shows robustness for disturbances and noises, can not be used in the case of uncertain system parameters. Even if the $H{\infty}$ controller can be designed for the parameter uncertain system, its performance can be deteriorated. Therefore, in this paper, the robustness of $H{\infty}$ controller is improved by using the SMC(Sliding Mode Control). The LMI based $H{\infty}$ controller is designed first and then SMC controller is added.

Robust Position Control of a Reaction Wheel Inverted Pendulum (원판의 반작용을 이용한 역진자의 강인 자세 제어)

  • Park, Sang-Hyung;Lee, Hae-Chang;Lim, Seong-Muk;Kim, Jung-Su
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.2
    • /
    • pp.127-134
    • /
    • 2016
  • This paper presents a robust control of a reaction wheel inverted pendulum. To this end, a mathematical model is derived using physical laws, and then parameters in the model are identified as well. Based on the model, a robust position control is designed, which consists of two parts: swing-up control using passivity and robust stabilization control using LMI (Linear Matrix Inequality). When the pendulum starts to move, the swing-up control is applied. If the position of the pendulum is near the desired upright position, the control is switched to the robust stabilization control. This robust control is employed in order to deal with the uncertainties in the inertia of the pendulum dynamics. The performance of the proposed control scheme is validated not only simulation but also real experiment.

Robust Controller Design of Multivariable Plant using Sensitivity Minimization (감도 최소화 기법을 이용한 다변수 플랜트의 강인한 제어기 설계)

  • 이원규;김영달
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.6
    • /
    • pp.42-50
    • /
    • 1993
  • In this paper the affect an inorganic filler and a f i n g up water absorption in epoxy composite material was represented. The results are summarized as follows ; 1. In the case of Sample 1, Sample 2 and a fillng up water absorption, the frequency depenence of E,' shows the straight characteristic underl4O0C. 2. Between lOOHz and 3kHz, the frequency dependency of tan8 is dominated by the loss of a dipole relaxation than the conductive loss for movement of a career. The effect of water absorption, is increased as the frequency is d e creased.

  • PDF

Evaluation of Robust Performance of Fuzzy Supervisory Control Technique (퍼지관리제어기법의 강인성능평가)

  • Ok, Seung-Yong;Park, Kwan-Soon;Koh, Hyun-Moo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.41-52
    • /
    • 2005
  • Using the variable control gain scheme on the basis of fuzzy-based decision-making process, Fuzzy supervisory control (FSC) technique exhibits better control performance than linear control technique with one static control gain. This paper demonstrates the effectiveness of the FSC technique by evaluating the robust performance of the FSC technique under the presence of uncertainties in the models and the excitations. Robust performance of the FSC system is compared with that of optimally designed LQG control system for the benchmark cable-stayed bridge presented by Dyke et al. Parameter studies on the robust performance evaluation are carried out by varying the stiffness of the bridge model as well as the magnitudes of several earthquakes with different frequency contents. From the comparative study of two control systems, FSC system shows the enhanced control performance against various magnitudes of several earthquakes while maintaining lower level of power required for controlling the bridge response. Especially, FSC system clearly guarantees the improved robust performance of the control system with stable reduction effects on the seismic responses and slight increases in total power and stroke for the control system, while LQG control system exhibits poor robust performance.