• Title/Summary/Keyword: 강성 모델

Search Result 1,126, Processing Time 0.033 seconds

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

The relationship between catechol-O-methyltransferase gene polymorphism and coronary artery abnormality in Kawasaki disease (가와사키병의 관상동맥 이상과 catechol-O-methyltransferase 유전자의 단일염기다형성)

  • Lee, Hyo Jin;Lee, Myung Sook;Kim, Ji Sook;Kim, Eun Ryoung;Kang, Sung Wook;Kim, Soo Kang;Chung, Joo Ho;Yoon, Kyung Lim;Han, Mi Young;Cha, Seong Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.87-92
    • /
    • 2009
  • Purpose : Many gene polymorphisms are associated with coronary artery abnormalities in Kawasaki disease. Catechol-O- methyltransferase (COMT) plays an important role in the metabolism of catecholamines, catechol estrogen, and catechol drugs. Polymorphisms of the COMT gene are reported to be associated with myocardial infarction and coronary artery abnormalities. The aim of this study was to evaluate the relationship between COMT gene polymorphisms and coronary artery abnormalities in Kawasaki disease patients. Methods : One hundred and one Korean children with Kawasaki disease and 306 healthy Korean control subjects were enrolled in this study. The polymorphisms of the COMT gene were analyzed by direct sequencing. Results : There were no differences in the genotype and allelic frequency of the rs4680 and rs769224 polymorphic sites between Kawasaki disease and control subjects. Further, no significant difference was found in the rs4680 polymorphism between patients with coronary artery abnormalities and patients without coronary artery abnormalities (codominant P=0.32, dominant P=0.74, recessive P=0.13). However, the distribution of the rs769224 polymorphism was significantly different between patients with coronary artery abnormalities and patients without coronary artery abnormalities (codominant P= 0.0077, dominant P=0.0021, recessive P=0.16). Conclusion : Our results indicate that the polymorphisms of the rs769224 gene might be related to the development of coronary artery abnormalities in Kawasaki disease.

Studies on the Therapeutic Effect and Mechanism of Korean Red Ginseng Total Saponin on Infertility Caused by Polycystic Ovaries (홍삼사포닌 투여의 다낭성난소에 의한 불임 치료효과 및 기작연구)

  • Kim, Se-Eun;Oh, Dong-Min;Sim, Kyung-Mi;Jeong, Moon-Jin;Lim, Sung-Chul;Nah, Seung-Yeol;Lee, Yun-Lyul;Kang, Seong-Soo;Moon, Chang-Jong;Kim, Jong-Choon;Kim, Sung-Ho;Bae, Chun-Sik
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Experimental induction of polycystic ovary (PCO) resembling some aspects of human PCO syndrome was produced using the long-acting compound estradiol valerate (EV). Our previous study on the role of Korean red ginseng total saponins (GTS) in a steroid-induced PCO rat model demonstrated that electro-acupuncture modulates nerve growth factor (NGF) concentration in the ovaries. In fact, the involvement of a neurogenic component in the pathology of PCO-related ovarian dysfunction is preceded by an increase in sympathetic outflow to the ovaries. In the present study, we tested the hypothesis that therapeutic GTS administration modulates sympathetic nerve activity in rats with PCO. This was done by analyzing NGF protein and NGF mRNA expression involved in the pathophysiological process underlying steroid-induced PCO. EV injection resulted in significantly higher ovarian NGF mRNA expression in PCO rats compared to control rats, and PCO ovaries were counteracted by GTS administration with significantly lower expression of NGF mRNA compared to EV treated ovaries. However, NGF protein was unaffected in both EV and GTS treated ovaries compared to control rats. These results indicate that EV modulates the neurotrophic state of the ovaries, which may be a component of the pathological process by which EV induces cyst formation and anovulation in rodents.

Comparison of 99mTc-Tin colloid colloid and 99mTc-DISIDA Hepatoscintigraphy in Miniature Pigs (미니돼지에서 99mTc-Tin colloid와 99mTc-DISIDA를 사용한 간신티그라피의 비교 연구)

  • Shim, Kyung-Mi;Kim, Se-Eun;Lee, Won-Guk;Koong, Sung-Soo;Bae, Chun-Sik;Lee, Jae-Yeong;Choi, Seok-Hwa;Han, Ho-Jae;Kang, Seong-Soo;Park, Soo-Hyun
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.1060-1065
    • /
    • 2006
  • Non-invasive evaluation of liver function in animal models remains a challenge. Hepatoscintigraphy provides information about changes in liver size and shape, and enables to understand general liver function. Futhermore it is readily used to diagnosis complications of liver transplantation like hepatitis, rejections and biliary complications. In this study, we investigated the usefulness of evaluating the liver function in miniature pigs with $^{99m}Tc-Tin$ colloid and $^{99m}Tc-DISIDA$ which are the most commonly used radiopharmaceuticals in human medicine. In result, $^{99m}Tc-Tin$ colloid was uptaked in lung, liver, gastric wall and kidney in miniature pigs. And $^{99m}Tc-DISIDA$ showed continuous uptake images of heart, lung, liver, gallbladder and duodenum, and it was similar to human's. Therefore we could conclude $^{99m}Tc-Tin$ colloid would not be suitable for evaluating hepatic function because of it's nonspecific affinity, however $^{99m}Tc-DISIDA$ scintigraphy would be an effective method for detecting hepatobiliary function in miniature pigs.

Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석)

  • Yoo, Sung-Won;Yang, In-Hwan;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.185-193
    • /
    • 2015
  • Ultra high performance concrete (UHPC) has been developed to overcome the low tensile strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.