Potential for Development of Bank Filtrate in the Nakdong River Basin (낙동강 유역의 강변여과수 개발 가능성)

  • 전흥배;김상일
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.4
    • /
    • pp.99-116
    • /
    • 1997
  • In order to obtain safe drinking water, free from surface contamination, a study to determine the potential for developing a bank-filtrate system in the Iryong and Yongsan, Nakdong River Basin, Korea was conducted. The main type of aquifer In the study area is alluvial, consisting mostly of sand and gravel. The hydraulic conductivity(k) of the Iryong and Yongsan test areas were 8.63${\times}$10$^-2$cm/s and 9.90${\times}$10$^-2$cm/s, respectively, indicating that these areas are satisfactory for bank filtrate production. Pilot plants(IRPL and YSPL) were set up In Iryong and Yongsan to monitor the change in the quality of bank-filtered water and to determine the effect pumping had on the surrounding hydrogeologic system. The pilot plants operated continuously for about two months and the data obtained were used to validate the groundwater flow model. Computer simulations were conducted to predict the effects of producing bank filtrate using MODFLOW. MODPATH was also linked with the flow model to analyze particle tracking. According to the results of the model simulations and the hydrogeologlc study, long-term pumping, the minimization of drawdown and the availability of uncontaminated sell and groundwater conditions for the catchment area were all Important factors for successful bank-titrate system development.

  • PDF

Greenhouse Heating Technology Development by using Riverbank Filtration Water (강변여과수를 이용한 온실난방기술 개발)

  • Moon, Jong-Pil;Lee, Sung-Hyoun;Kwon, Jin-Kyung;Kang, Youn-Ku;Ryou, Young-Sun;Lee, Su-Jang
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

Study on the Water Quality of Bank Filtration Depending on Soil Characteristics (토양특성에 따른 강변여과수의 수질에 관한 연구)

  • Na, Hyeon-Young;Kwon, Dae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.19-26
    • /
    • 2011
  • In this research, soil analysis and adsorption were conducted, and compared with the water quality of bank filtration and river in terms of TS, TDS, SS, $NH_4$-N, $NO_3$-N, $NO_2$-N, Fe, Mn, BOD and $KMnO_4$ consumption for the development of bank filtration in Gimhae city. Analysis of soil showed high levels of Fe (470 mg/kg), Mn (80 mg/kg) and $NH_4$-N (15 mg/kg). Also, adsorption coefficient values (k and 1/n) were 0.00159 and 0.8714, respectively. This implies that the adsorption of the soil depends on organic matter. Water qualitiy of the river and the bank filtration revealed that the concentrations of TS and TDS almost didn't change but the concentration of SS decreased 84% through the bank filtration. $NH_4$-N in the bank filtration was detected more than 1 mg/L which might be due to agricultural activities in the research area. $NO_3$-N was close to the detection limit owing to the removal by the adsorption. $KMnO_4$ consumption and BOD of the river were decreased by the bank filtration 250% and 350%, respectively, while Fe and Mn were significantly increased by the bank filtration.

Numerical Study on Behavior of Underground Freshwater Body with Variation of Freshwater Injection in a Coastal Aquifer (염수대수층 내 담수 주입 변화에 따른 지하 담수체 거동에 대한 수치모의)

  • Jeong, Woo Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.249-249
    • /
    • 2015
  • ASR(Aquifer Storage Recharge) 또는 ASTR(Aquifer Storage Transfer Recharge)과 같은 직접적인 지하수 인공함양기법은 대수층을 활용하여 수자원을 공급하고 관리하기 위한 적극적인 방안으로 고려될 수 있다. 이 중 ASTR 기법은 대규모 충적층이 발달한 강변 또는 하구에서 저류지 수생식물의 정화작용과 층적층의 물리/화학/생물학적 여과 기능을 활용하여 양질의 상수원수를 확보할 수 있는 기법이며, 수질이 나쁜 하천수를 직접 취수하여 정수처리하는 것에 비해 정수비용이 상대적으로 적게 들어 투자대비 경제적인 상수원수 확보기술이라 할 수 있다. 본 연구에서는 하구에 염수 대수층이 위치해 있다고 가정하였으며, 이러한 염수 대수층 내에 담수 주입 변화에 따른 지하 담수체의 거동을 4가지 시나리오에 따라 모의 및 분석을 통해 조사하였다. 염수 대수층 내에서 8개의 주입정과 1개의 양수정이 설치되어 있다고 가정하였으며, 주입정은 동심원 상에 등간격으로 위치해 있으며, 양수정은 동심원 중에 위치해 있다고 가정하였다. 본 연구에서 구성된 시나리오로 첫 번째는 주입정 8개 모두에서 동시에 주입되며, 1개의 양수정을 통해 양수되는 것이며, 두 번째는 7개의 주입정에 주입 그리고 1개의 주입정 폐쇄, 세 번째는 6개 주입정에 주입 및 양수정과 서로 마주보는 2개 주입정 폐쇄, 그리고 마지막으로 6개 주입정에 주입 및 서로 이웃한 2개 주입정 폐쇄이다.

  • PDF

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.

Optimum Pumping Rates of Ground-Water Heat Pump System Using Groundwater or Bank Infilterated Water (강변여과수와 천부 지하수를 이용하는 지하수 열펌프시스템의 적정유량)

  • Hahn, Jeong-Sang;Han, Hyuk-Sang;Hahn, Chan;Jeon, Jae-Soo;Kim, Hyong-Soo
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.833-841
    • /
    • 2007
  • The groundwater heat pump system(GWHP) is one of the most efficient ground source heat pump system(GSHP) which uses low grade and shallow geothermal energy for cooling and heating purpose. The GWHP system shall be designed properly based on peak block load performance and optimum pumping rate of groundwater comparable to ground coupled heat pump system(GCHP). The optimum pumping rate depends on groundwater temperature at a specific site, size of plate heat exchanger, and total head loss occurred by whole system comprising pumps and pipings. The required optimum flow rates of the system per RT are ranged from 3.8 to 9.8lpm being less than the typical building loop flow of 9.5 to 11.4lpm.

Unit Water Production Cost Development for Alternative Water Resource Projects - Centered on the Economics of Aquifer Storage and Recovery (ASR) - (대안수자원시설의 음용수 단위생산비용 산출 - 청정지하저수지 경제성에 대한 고찰 -)

  • Choi, Jae-Ho;Shim, Young-Gyoo;Park, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.611-619
    • /
    • 2017
  • This paper intends to develop unit water production cost (UWPC) between alternative water resources including desalination, freshwater reservoirs, single-purpose dams, underground dams, and two indirect water in-take technologies - riverbank filtration and aquifer storage and recovery (ASR). The UWPCs of water supply schemes including each alternative are determined based on project cost, and operation and maintenance estimation models, which were developed based on real project cost data. The sensitivity analysis of UWPCs reveals that ASR is the lowest cost option in producing drinkable water among the alternatives, followed by riverbank filtration and underground dam. It is expected that economics related to the finding plays a critical role in supporting water resources planning and budget allocation for central and local water authority in Korea.

A Cost-Benefit Analysis of Groundwater: Pumping Wells in Korea (지하수의 경제성 평가 연구: 지하수 관정을 중심으로)

  • Kim, Sun Geun
    • Economic and Environmental Geology
    • /
    • v.47 no.3
    • /
    • pp.219-225
    • /
    • 2014
  • In Korea, there are 1,474 thousand pumping wells nationwide which account for about 12% of total water use in 2012. As much as 39 hundred million tons of groundwater were used while 333 hundred million tons of total water were supplied in 2012. Because the water management authority projects that water demand will exceed supply by 2021, the authority is planning to extensively expand groundwater use in accordance with economic feasibility. Using the basic frameworks of cost-benefit analyses of the World Bank and the US Environmental Protection Agency (US EPA), the objective of this study is to examine the costs and benefits of the expansion of Korea's groundwater extraction through pumping wells. We conclude that the BC ratio of the groundwater pumping wells is 2.98. This signifies that the benefits are 2.98 times higher than the costs. The benefits include use and non-use values of pumping wells while the costs include the installation and maintenance of new wells, in addition to the restoration and pollution costs of abandoned wells, as well as fees for water quality tests, etc.

A Cost-Benefit Analysis of Groundwater Supply through Pumping Well Technology

  • Kim, Sun G.
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2015.11a
    • /
    • pp.479-487
    • /
    • 2015
  • In Korea, there are 1,474 thousand pumping wells nationwide which account for about 12% of total water use in 2012. As much as 39 hundred million tons of groundwater were used while 333 hundred million tons of total water were supplied in 2012. Because the water management authority projects that water demand will exceed supply by 2021, the authority is planning to extensively expand groundwater use in accordance with economic feasibility. Using the basic frameworks of cost-benefit analyses of the World Bank and the US Environmental Protection Agency (US EPA), the objective of this study is to examine the costs and benefits of the expansion of Korea's groundwater extraction through pumping wells. We conclude that the BC ratio of the groundwater pumping wells is 2.98. This signifies that the benefits are 2.98 times higher than the costs. The benefits include use and non-use values of pumping wells while the costs include the installation and maintenance of new wells, in addition to the restoration and pollution costs of abandoned wells, as well as fees for water quality tests, etc.

  • PDF

Subsurface Water Storage Using Coastal Aquifers Filled With Saline Water (염수로 포화된 해안지역 대수층을 활용한 수자원확보 방안)

  • Jung, Eun Tae;Park, Namsik;Kim, In Chul;Lee, Seoung Hwi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.353-357
    • /
    • 2015
  • A new method is proposed for water resources using aquifers in coastal areas. These aquifers are generally filled with saline water due to seawater intrusion and consequently being left unutilized. Surface water can be injected into these aquifers and recovered for water quality enhancement and stored water. Injection and pumping wells are used. For this technique to be successful protection of pumping well from seawater intrusion is an essential issue. Salt water pumping can be used to prevent saline water upconing. Numerical analysis demonstrated that a properly designed and executed salt water pumping well can protect a freshwater pumping well from salt water intrusion.