• Title/Summary/Keyword: 강도발현 특성

Search Result 544, Processing Time 0.032 seconds

Properties of Strength Development of Concrete at Early Age Using High Fineness Cement and Fly Ash (고분말도 시멘트와 플라이애시를 치환한 콘크리트의 조기강도 발현 특성)

  • Ha, Jung-Soo;Kim, Han-Sic;Lee, Young-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.154-160
    • /
    • 2018
  • Cement industries are considered key industries for reducing carbon emissions, and efforts are off the ground to reduce the use of cement in the concrete sector. As a part of this effort, research is off the ground to utilize a large amount of industrial by-products that can be used as a substitute for a part of cement. Concrete using industrial by-products has advantages such as durability, environment friendliness and economical efficiency, but there are problems such as retarding and early-age strength deterioration. Therefore, this study aimed to reduce the use of cement and solve the problem of early-age strength deterioration while using fly ash, which is an industrial by-product. Accordingly, it was confirmed that the strength was improved at all ages irrespective of curing temperature by accelerating the hydration reaction by using high fineness cement. Subsequently, high fineness cement was partially replaced with fly ash and the strength development characteristics were examined. As a result, it was possible to exhibit strength equal to or higher than ordinary portland cement even at the early age. Also, it was confirmed that even when the fly ash is replaced by 30%, it is possible to shorten the time for dismantling the forms of vertical and horizontal members.

The Microstructure and Durable Properties of the Composites with the Ground Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 몰탈의 미세구조와 내구특성)

  • Kim, Won-Ki;Soh, Jung-Sub;Kim, Dong-In;Kim, Hoon-Sang;Kim, Hong-Joo
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2004.05a
    • /
    • pp.143-148
    • /
    • 2004
  • 고로슬래그 미분말과 플라이 애쉬와 같은 재료들이 콘크리트의 내구성과 장기강도 증진을 목적으로 혼합재로서 사용되고 있다. 본 연구에서는 고로슬래그 사용 몰탈의 내구성 증진 특성을 활용하기 위하여 고로슬래그 미분말에 알칼리 자극제를 첨가한 알칼리 활성화 슬래그계 무기결합재 사용 몰탈의 내구성과 물리적 특성을 평가하였다. 실험결과, 몰탈의 초기 압축강도 발현에 알칼리 자극제가 큰 영향을 미치는 것을 확인하였다. 또한 알칼리 자극제가 첨가된 몰탈의 화학적 저항성을 평가하기 위하여 공시체를 재령 28 일 후, 5% 황산($H_2SO_4$) 용액에 침지하여 압축강도 및 질량 변화를 관찰하였다. 그 결과, 보통포틀랜드 시멘트로 제조한 몰탈의 경우, 황산용액 침지 후 압축강도가 54% 감소하였다. 반면 고로슬래그 미분말을 첨가한 몰탈의 경우, 약 10% 강도가 감소하였다. 질량변화의 경우, 보통포틀랜드 시멘트로 제조한 공시체는 17%, 고로슬래그 미분말을 첨가한 몰탈은 3%의 질량변화를 보였다. 이 결과로서 고로슬래그 미분말을 첨가한 몰탈의 경우, 화학적 저항성과 물리적 특성이 우수한 것을 확인하였다.

  • PDF

The Fundamental Property and Fire Resistance of the High Strength Concrete Corresponding to mixtures for the High Strength (고강도용 혼합재를 사용한 고강도 콘크리트의 기초물성 및 내화특성 검토)

  • Kim, Jong-Baek;Lee, Keon-Ho;Bae, Jun-Yeong;Jo, Sung-Hyun;Roh, Hyeon-Seung;Kim, Jung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.605-608
    • /
    • 2008
  • This study investigated fundamental properties corresponding to mixtures for the high strength, and their properties of spalling prevention after a fire test. The results were summarized as following. For the flowability of using mixtures for the high strength, the target flow was satisfied with a small quantity of high performance reducing water agent to compare with silica fume. For the compressive strength in the case of using mixtures for the high strength, it was higher to compare with silica fume at 7 days, so it was proved that using mixtures for the high strength was profitable to prevent early frost damage. The compressive strength at the 28 days of silica fume and mixtures for the high strength were similar. There was no reduced tendency at the compressive strength according fiber contents, so it found out that the bonding strength between the fiber and concrete was hardly effective. For the spalling properties, the specimens without fibers were destroyed, however using over 0.05% of NY and PP fibers was effective to prevent spalling on the high strength concrete.

  • PDF

A Study for Adfreeze Bond Strength Developed between Weathered Granite Soils and Aluminum Plate (동결된 화강풍화토와 알루미늄판 접촉면에서 발현되는 동착강도 측정 연구)

  • Lee, Joonyong;Kim, Youngseok;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.12
    • /
    • pp.23-30
    • /
    • 2013
  • Bearing capacity of pile is governed by only skin friction in frozen ground condition, while it is generally governed both by skin friction and end bearing capacity in typically unfrozen ground condition. Skin friction force, which arises from the interaction between pile and frozen soils, is defined as adfreeze bond strength, and adfreeze bond strength is one of the most important key parameters for design of pile in frozen soils. Many studies have been carried out in order to analyze adfreeze bond strength characteristics over the last fifty years. However, many studies for adfreeze bond strength have been conducted with limited circumstances, since adfreeze bond strength is sensitively affected by various influence factors such as intrinsic material properties, pile surface roughness, and externally imposed testing conditions. In this study, direct shear test is carried out inside of large-scaled freezing chamber in order to analyze the adfreeze bond strength characteristics with varying freezing temperature and normal stress. Also, the relationship between adfreeze bond strength and shear strength of the frozen soil obtained from previous study was analyzed. The coefficient of adfreeze bond strength was evaluated in order to predict adfreeze bond strength based on shear strength, and coefficients suggested from this and previous studies were compared.

A Study on the Strength Properties and the Temperature Curve of Winter Concrete According to the Difference of Curing Method in Mock-up Test (실물부재시험에서의 양생방법 차이에 따른 한중콘크리트외 온도이력 및 강도특성에 관한 연구)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.541-548
    • /
    • 2003
  • This study is to investigate the temperature curve and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of reducing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluation in-place concrete strength.

Experimental Evaluation of Bearing and Bond Strengths in Compression Splices (철근 압축이음에서 지압강도와 부착강도의 실험적 평가)

  • Chun, Sung-Chul;Lee, Sung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • Compression splices are required for all compression members in almost all of the floors in high-rise buildings. Therefore, a clear understanding of the behavior of compression splices can provide a rational design of compression splices. Tests of compression splices with bearing only and bond only cases were conducted to investigate the component resistance characteristics of compression splices. Test results showed that the circumferential tensile stresses induced by bearing and bond overlapped at the end of the splice length deterred bond and bearing splices from developing target splicing strength when both normal bond and bearing splices were used. In particular, the bearing strength was more significantly reduced than the bond strength since the bearing relied on the limited area near the end of the splice length. However, the strength of the normal splice was always higher than the strength of the bond only or the bearing only case. Consequently, the study results showed that splice strength in compression cannot be improved by means of removing bond or bearing. In addition, the bond strength in bond only splices was nearly same as the bond strength in tension splices and the strength increase of compression splice is attributed to end bearing only characteristic.

High Temperature Properties of Alumino Silicate Fire Protection Materials Using Fly ash (플라이애쉬 활용 Alumino silicate계 내화마감재의 고온특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Park, Nam-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.689-692
    • /
    • 2008
  • HSC(High Strength Concrete) have superior properties well as improvement in durability compared with normal strength concrete. In spite of durability of HSC, explosive spalling of concrete is serious problem in structure safety. Therefore, Solving methods are required to control the explosive spalling. The properties of concrete are affected by changes of temperatures. Compressive strength and elasticity modulus were degraded depending on a rise of temperatures. Also, change in microstructure and dehydration of concrete subjected to high temperatures. This paper is concerned with change in microstructure and dehydration of the alumino silicate fire protection materials at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of SEM, TG-DSC and XRD. From the experimental test results, influence of high temperatures on microstructure of alumino-silicate fire protection material was identified, including chemical dehydration of C-S-H and CH. The chemical dehydration of CH under various temperatures from to 450 to 600$^{\circ}$C has been measured using the TG-DSC. However, developed alumino silicate fire protection materials showed good stability in high Temperatures. Thus, the results indicate that it is possible to fireproof panels, fire protection of materials.

  • PDF

Behavior and Capacity of Compression Lap Splice in Unconfined Concrete with Compressive Strength of 40 and 60 MPa (횡보강근이 없는 40, 60 MPa 콘크리트에서 철근 압축이음의 거동과 강도)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.291-302
    • /
    • 2009
  • A compression lap splice can be calculated longer than a tension lap splice in high strength concrete according to current design codes. New criteria for the compression lap splice including the effects of concrete strength are required for practical purpose of ultra-high strength concrete. Characteristics of compression lap splice have been extensively investigated and main parameters are derived. In addition, an experimental study has been conducted with column specimens in concrete strength of 40 and 60 MPa. The strength of the compression lap splice consists of bond and end bearing and two contributors are combined. Therefore, combined action of bond and end bearing should be assessed. Compared with tension splices, concrete strength significantly affects the strength of compression splices due to short splice length and existence of end bearing. Test results show that the splice strength can be evaluated to be proportional to square root of compressive strength of concrete. The stress states of concrete surrounding spliced bars govern the strengths of bond and end bearing. Because the axial stress of the concrete is relatively high, the splice strength is not dependent on clear spacing. End bearing strength is not affected by splice length and clear spacing and is expressed with a function of the square root of concrete strength. The failure mode of specimens is similar to side-face blowout of pullout test of anchors and the strength of end bearing can be evaluated using the equation of side-face blowout strength. Because the stresses developed by bond in compression splices are nearly identical to those in tension splices, strength increment of compression splices is attributed to end bearing only.

Effect of Phosphate Types on the Strength and pH of Magnesia-Phosphate Composites (마그네시아 인산염 복합체의 강도 및 pH에 대한 인산염 종류의 영향)

  • Lee, Kyung-Ho;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • As an elementary investigation to develop vegetation concrete with a relatively low pH value, magnesia-phosphate composites (MPC) were examined according to the phosphate types including Monoammonium, Monosodium, Monopotassium, Monocalcium, Diammonium, Disodium, Dipotassium, and Diacalcium phosphates. All of the MPC binders, the ratio of magnesia to phosphate was fixed to be 7:3. MPC mortars activated with Disodium, Dipotassium, and Diacalcium phosphates showed no compressive strength gain, even at age of 28 days. Meanwhile, MPC mortars with Monoammonium and Monosodium phosphates developed 28-day compressive strength of more than 34MPa, and showed a relatively low pH value below 9.8. Hence, Monoammonium and Monosodium phosphates have potentials as an activator for producing MPC-based vegetation concrete.

Mixture Study for Early-age Strength Improvement of NAC-typed High-strength Concrete Piles (NAC 방식 고강도 콘크리트 파일의 초기강도증진을 위한 배합에 대한 연구)

  • Yi, Seong Tae;Noh, Jae Ho;Heo, Hyung Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.58-64
    • /
    • 2012
  • Due to the influence of global oil prices, industrial productivity, which oil consumption is high, was significantly reduced. AC type of high-strength PHC piles is being manufactured through twice the steam curing process and this have resulted in a significant rise for product's manufacturing costs. NAC way other types of file manufacturing process has the advantage of reducing manufacturing costs by a turn of the steam curing. Nevertheless, because the initial strength be poor than that of AC method, shipment is being after the curing period of approximately three days. In addition, the growth of the product enhance with curing period can not be avoided, as a result, cost of inventory is acting as the rise. Piles by the AC method is immediately shipped after curing, damaging problems does not occur when they are introduced to the field site (for example, pile on-site). In the case of NAC, however, at least after the curing period of three days and after expressing the strength of 80 MPa or more, they are shipped on the scene. Therefore, NAC type has problems as follows: (1) increase in moderate inventory holding costs with type and (2) breakage in the field due to lack of strength. In this study, for NAC-typed PHC files, mixing characteristics research for the strength development at 1 day equivalent to AC method were conducted and strength characteristics with changes of original materials were evaluated were also identified.