• Title/Summary/Keyword: 강도근

Search Result 833, Processing Time 0.021 seconds

Effects of Transverse Reinforcement on Flexural Strength and Ductility of High-Strength Concrete Columns (횡보강근에 따른 고강도 콘크리트 기둥의 휨강도와 연성)

  • 황선경;윤현도;정수영
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.365-372
    • /
    • 2002
  • This experimental investigation was conducted to examine the behavior of eight a third scale columns made of high-strength concrete(HSC). The columns were subjected to constant axial load corresponding to target value of 30 percent of the column axial load capacity and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement(Ps=1.58, 2.25 %), tie configuration(hoop-type, cross-type, diagonal-type) and tie yield strength(fy=5,600, 7,950 kgf/$\textrm{cm}^2$). Test results indicated that the flexural strength of all the columns did not exceed calculated flexural capacities based on the equivalent concrete stress block used in current design code. Columns with 42 percent higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-99 were shown ductile behavior. With axial load of 30 percent of the axial load capacity, the use of high-strength steel as transverse reinforcement may lead to equal or higher ductility than would be achieved with low-strength steel.

An Experimental Research on the Confinement Effect of Concrete Specimens with Spirals (나선근에 의한 콘크리트의 횡보강 효과에 관한 실험적 연구)

  • 김진근;박찬규
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.2
    • /
    • pp.146-154
    • /
    • 1995
  • I n this paper, an experimental research was carried out to investigate the confinement effect of spiral reinforcements in concrete column specimens subjected to t.he concentric axial corn pressive loads. Main variables were the compressive strengths of concrete of 27.2, 62.4 and 81.2 MPa, and the spacings of spirals of 120, 60, 40, 30, 25 and 20mm. and the yield strengths of spir als of 451 and 1375MPa, respectively. For the same volumetric ratio and yield strength of spir als, it was shown that the strength increment of confined concrete was almost same regardless of the strength of unconfined concrete, however, the axial stram at maximum stress was decreas ed with increasing of the compressive strength of unconfined concrete.

Effects of Graded Exercise-Induced Fatigue on the Knee Joint Position Perception (운동강도에 따라 유발된 근피로가 슬관절 위치감각 인지에 미치는 영향)

  • Choi, Jong-Duk;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.10 no.4
    • /
    • pp.61-68
    • /
    • 2003
  • 본 연구의 목적은 운동강도(최대근수축의 10, 30, 50, 70%)에 따라 유발되는 국소적인 근피로가 슬관절의 위치감각 인지에 미치는 영향을 연구함으로써 근력강화의 운동치료적 효과와 운동학습과 관련된 효과를 동시에 만족시키는 최적의 운동강도를 제시하는 것이었다. 대상자는 건강한 성인여자 40명이었다. 청각을 통한 위치감각 정보를 제공하는 장치와 원판 각도계가 부착된 등속성 Cybex를 사용하였다. 근피로의 상태를 확인하기 위해서 근전도를 이용하여 주파수 스펙트럼 분석을 실시하였다. 청각되먹임이 주어진 각도와 대상자에 의해 재생되어진 각도의 오차값들과 근피로의 변화를 비교하기 위해 일요인 분산분석을 이용하였다. 오차값들의 평균은 50%의 군에서 가장 작았으며 근피로 또한 70%의 군에서만 크게 생성되었다. 따라서 최대 근 수축력의 50%가 운동치료 시 가장 효과적인 운동강도임을 알 수 있었다.

  • PDF

Bond Properties of CFRP Rebar in Fiber Reinforced High Strength Concrete with Surface Treatment Methods of Reinforcing Fibers (보강섬유의 표면처리에 따른 섬유보강 고강도콘크리트와 CFRP 보강근의 부착특성)

  • Park, Chan-Gi;Won, Jong-Pil;Cha, Sang-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.275-282
    • /
    • 2009
  • The effects of surface treatment method of reinforcing fiber on the bonding strength between carbon fiber reinforced polymer rebar (CFRP rebar) and high strength concrete have been evaluated in this study. The structural PVA fiber is coated with a proprietary hydrophobicoiling agent and crimped type polyolefin based structural synthetic fiber is deformed with a geometrical modification were used for the reinforcing fiber. The compressive tests have been performed to evaluate the strength property of high strength concrete depending on the surface treatment method of fiber. The bonding property between the high strength concrete and the CFRP rebar was evaluated by means of direct bonding test. The test results indicated that the surface treatment method of fiber effect on the bonding behavior of high strength concrete and CFRP rebar. Also, as the development and propagation of splitting cracks were controled by adding fibers into the high strength concrete, the bonding behavior, bond strength and relative bonding strength of CFRP rebar and high strength concrete were significantly improved.

Bond Failure Surface of Glass Fiber Reinforced Polymer Bars (GFRP 보강근의 부착파괴면)

  • Lee, Jung-Yoon;Yi, Chong-Ku;Kim, Tae-Young;Park, Ji-Sun;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.383-391
    • /
    • 2008
  • The effects of concrete strength on bond-slip behavior and the failure mechanisms of glass fiber reinforced polymer (GFRP) bar embedded in concrete under direct pullout were investigated in this study. Total of twenty seven specimens were prepared by placing two different types of GFRP bars and conventional steel rebar in 25 MPa, 55 MPa, and 75 MPa concrete and tested according to CSA S806-02. The test results showed that the bond strength of the GFRP rebars as well as the steel increased with the concrete strength. However, the increase in the bond strength with respect to the concrete strength was not as significant in the GFRP series as the steel, and it was attributed to the interlaminar failure mechanism observed in the GFRP test specimens.

Experimental Study on the Bond Properties between GFRP Reinforcements and Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트와 GFRP 보강근의 부착특성에 관한 실험적 연구)

  • Choi, Yun-Cheul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.573-581
    • /
    • 2013
  • In this paper, an experimental investigation of bond properties between steel fiber reinforced concrete and glass fiber reinforced polymer reinforcements was performed. The experimental variables were diameter of reinforcements, volume fraction of steel fiber, cover thickness and compressive strength of concrete. Bond failure mainly occurred with splitting of concrete cover. Main factor for splitting of concrete is tension force occurred by the displacement difference between reinforcements and concrete. Therefore, in order to prevent the bond failure between reinforcements and concrete, capacity of tensile strength of concrete cover should be upgraded. As a results of test, volume fraction of steel fiber significantly increases the bond strength. Cover thickness changes the failure mode. Diameter of reinforcements also changes the failure mode. Generally, diameter of reinforcement also affects the bond properties but this effect is not significant as volume fraction of fiber. Increase of compressive strength increases the bond strength between concrete and reinforcement because compressive strength of concrete directly affects the tensile strength of concrete.

Bond Behavior of GFRP Rebars Embedded in Concrete Under Cyclic Loading (반복하중을 받는 GFRP 보강근의 부착특성)

  • Cheong, Yeon-Geol;Yi, Chong-Ku;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.101-104
    • /
    • 2008
  • The cost of repairing the deterioration of concrete structures due to corrosion of the reinforcement steel has been the prominent figure in the maintenacne of the reinforced-concrete infrastructures. As an alternative material to steel reinforcement, the use of Fiber Reinforced Polymer (FRP) bar in concrete is being actively studied for the high resistance of chemical environment and high strength to weight ratio properties of FRP. However, there remain various aspects of FRP properties that still need to be studied before the standard design criteria can be established. One of the imminent issues is the bond between FRP and concrete. In this study, the bond-behavior of FRP bars in concrete is investigated via the pullout test with three varying parameters: surface condition of FRP bars, concrete compression strength, and cyclic loading patterns. As a result of experiment, the bond strength of GFRP increased with the concrete compression strength increasing and decreased with applying cyclic load.

  • PDF

Shear Strength of Reinforced High Strength Concrete Deep Beams with Geometric Condition (기하학적 경계조건을 고려한 고강도 철근 콘크리트 춤이 큰 보의 전단강도)

  • 오정근;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.109-118
    • /
    • 1998
  • 전단거동에 의해 지배되는 고강도 철근콘크리트 춤이 큰 보의 전단역학적 거동 및 전단강도특성을 고려한 이론식을 제시하고자 소성이론에 근거한 극한해석에서 상계치정리를 이용하여 이론적 전개를 하였으며, 고강도 R/C춤이 큰 보의 전단응력에 영향을 미치는 콘크리트 압축강도, 수직전단보강근 및 수평잔단보강근의 보강효과를 고려한 이론식을 제시하였으며, 수평철근 즉 주인장철근 및 수평전단보강근의 장부작용을 고려하였다. 실험결과와 비교할 때 제안식은 수직잔단보강근의 전단보강효과를 과대평가하고있으며, 수평전단보강근의 효과를 적절하게 평가하고 있음을 나타내었다. 또 전단스팬비가 0.5, 0.85인 경우에는 제안식에 의한 값이 다소 낮게 나타내, 전단스팬비가 낮은 경우는 다소 과소평가하는 것으로 나타났다.

Bond Capacity of U-shaped reinforcement for bond splitting prevention in RC beams (고강도 횡 보강근을 적용한 RC보의 정량적인 부착강도 평가)

  • Yoon, Hye-Sun;Kim, Young-Sik;Yang, Wan-Su;Beak, Sung-Cheol;Kim, Kil-Hee
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.105-108
    • /
    • 2008
  • Although the research of high strength materials is in process briskly in the inside and outside of the country, in south korea, the research of high strength materials is insufficiency. Generally shear resistance of RC beam is influenced dominantly by amount of shear-reinforcing bars($p_w$) and yied strength($f_{wy}$). Therefore, I come to the conclusion that if use shear reinforced bar with shear reinforced bar, it leads to decrease of the quantity of shear reinforced bar and effects on the security of shear-restraint force of member. This study experimented with not only the mixture of high strength-reinforced bar and U-shaped reinforcement normal strength -reinforced bar devises efficient improvement, but also it incites improvement of bond capacity and carries out an experimental study for improvement of member resisting force, finally it evaluates bond capacity quantitatively on the lines of main reinforcement the restraint method.

  • PDF

Behavior and Capacity of Compression Lap Splice in Confined Concrete with Compressive Strength of 40 and 60 MPa (횡보강근이 있는 40, 60 MPa 콘크리트에서 철근 압축이음의 거동과 강도)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.389-400
    • /
    • 2009
  • A compression lap splice can be calculated longer than a tension lap splice in high strength concrete according to current design codes. Including effects of transverse reinforcement, a compression splice becomes much longer than a tension splice. Effects of transverse reinforcement and bar size on strength and behavior of compression lap splice, which always exist in actual structures, have been investigated through experimental study of column tests with concrete strength of 40 and 60 MPa. The results of the tests with bar diameters of 22 and 29 mm show that there is no size effect of bar diameter on compression lap splice. Bond strength of small bar diameter may increase. However, large diameters of re-bars are used in compression member and the size effect of re-bars does not have to be considered in compression lap splice. Confined specimens have twice of calculated strengths by current design codes. New design equations for the compression lap splice including the effects of transverse reinforcement are required for practical purpose of ultra-high strength concrete. End bearing is enhanced by transverse reinforcement placed at ends of splice not by transverse reinforcement within splice length. As more transverse reinforcement are placed, the stresses developed by bond linearly increase. The transverse reinforcements at ends of splice a little improve the strength by bond. Because the stresses developed by bond in compression splice with transverse reinforcement are nearly identical to or less than those in tension splice with same transverse reinforcement, strength increment of compression splice is attributed to end bearing only.