• Title/Summary/Keyword: 감마-선

Search Result 1,495, Processing Time 0.028 seconds

Peak Analysis of Gamma-ray and X-ray (감마선 및 엑스선의 피이크 분석)

  • Kim, Seung-Kon;Herr, Young-Hoi;Park, Kwang-June
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 1984
  • A great variety of nuclear gamma rays emitted from fission and activation products of spent nuclear fuel contains much information that can be elicited without affecting the integrity of the fuel elements. But the extraction of such information from the complex spectrum is difficult and requires computer codes. In the present work, a versatile code 'CAERI' was developed which locates peaks and calculates their areas for X-rays as well as gamma rays using elegant features of some widely used programs for gamma-ray peak fitting. 'CAERI' coded in FORTRAN used infinite series approximation more accurate than other workers various, simple, piecewise series approximations for evaluations of the Voigt function which represents the X-ray peak with non-negligible natural line width. 'CAERI' can handle even a complex multiplet consisting of peaks from X-rays and gamma rays in arbitrary mixture, which one often encounters in the isotopic analysis of heavy elements such as U and Pu. The results of the fitting performed on the test spectra of $^{177m}\;Lu\;{\gamma}-ray\;and\;^{235}U\;K_{\alpha}$X-ray show good agreement with those by previous workers.

  • PDF

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Design of Gamma Camera with Diverging Collimator for Spatial Resolution Improvement (공간분해능 향상을 위한 확산형 콜리메이터 기반의 감마카메라 설계)

  • Lee, Seung-Jae;Jang, Yeongill;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.661-666
    • /
    • 2019
  • Diverging collimators is used to obtain reduced images of an object, or to detect a wide filed-of-view (FOV) using a small gamma camera. In the gamma camera using the diverging collimators, the block scintillator, and the pixel scintillator array, gamma rays are obliquely incident on the scintillator surface when the source is located the periphery of the FOV. Therefore, the spatial resolution is reduced because it is obliquely detected in depth direction. In this study, we designed a novel system to improve the spatial resolution in the periphery of the FOV. Using a tapered crystal array to configure the scintillation pixels to coincide with the angle of the collimator's hole allows imaging to one scintillation pixel location, even if events occur to different depths. That is, even if is detected at various points in the diagonal direction, the gamma rays interact with one crystal pixel, so resolution does not degrade. The resolution of the block scintillator and the tapered crystal array was compared and evaluated through Geant4 Application for Tomographic Emission (GATE) simulation. The spatial resolution of the obtained image was 4.05 mm in the block scintillator and 2.97 mm in the tapered crystal array. There was a 26.67% spatial resolution improvement in the tapered crystal array compared to the block scintillation.

The Ethanol Extract of Red Ginseng Enhances Anti-Tumor Effects Using Co60 Gamma Irradiation (홍삼의 에탄올 추출물의 감마선 조사를 통한 항암효과 증대)

  • Hur, Jung-Mu;Kim, Dong-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.1
    • /
    • pp.15-20
    • /
    • 2011
  • Red ginseng is one of the most popular traditional medicines in Korea. In this study, we developed a new technique in which ethanol extract of $\underline{r}$ed $\underline{g}$inseng (HRG) was exposed to the $Co^{60}$ gamma radiation ranging from 1~5 kGy. The irradiated HRG (IHRG) were analyzed by high performance liquid chromatography (HPLC) to determine any compositional changes of ginsenosides due to irradiation. No appreciable difference was observed in the HPLC pattern of ginsenosides of HRG. Using MTT assay, the cytotoxicity effect was significantly increased by IHRG compared to HRG. The $LD_{50}$ concentration was $30{\mu}g/mL$ for IHRG-1 (1 kGy), and $15{\mu}g/mL$ for IHRG-5 (5 kGy). The evidences of apoptosis, such as nuclei cleavage and Annexin V staining, were observed in the human prostate cancer PC-3 cells treated with the IHRG. Additionally, the level of reactive oxygen species (ROS) was apparently elevated by IHRG. We also studied the inhibitory effect of IHRG on the growth rate of tumor xenografts in BALB/c male mice. The tumor growth rates were inhibited by 56.9 and 76.1% in mice treated with 10 mg/kg of IHRG-1 and IHRG-5, respectively, compared with control group (21.1%). These results suggest that some biologically active and soluble components in HRG can be more effectively enhancement of anti-tumor effects using irradiation.

Effects of Gamma Radiation on Fiber Bragg Gratings by the Fiber Re-coating Methods (광섬유 브래그 격자의 재코팅 방법에 따른 감마 방사선의 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.782-784
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings on the fiber re-coating methods. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of 100 kGy at the dose rate of 104 Gy/min. In our experimental results, we confirmed that the fiber acrylate re-coating process leads to a slightly lower radiation sensitivity of FBGs.

  • PDF

Analysis of 766 keV Gamma Peak from NPP Environmental Samples (원전주변 환경시료의 766 keV 감마선에너지 피크에 대한 해석)

  • Kim, Wan;Lee, Hae-Young;Yang, He-Sun;Park, Hae-Soo;Kim, Bong-Kuk;Park, Hwan-Bae;Kim, Hong-Joo;Lee, Sang-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.190-194
    • /
    • 2009
  • Gamma spectral results for macroalgae samples taken from the environment of Ulchin nuclear power plants in Korea (east coast), showed 766 keV peaks, which were identified as $^{95}Nb$ by several research institutes. After the enhancement of liquid radioactive waste disposal facility at Ulchin NPP site, the $^{95}Nb$ amount in the liquid radioactive waste outflow has drastically reduced, but the expected reduction in $^{95}Nb$ specific activity from environmental samples did not actually show up on gamma spectroscopy. Detailed re-investigation revealed that along with 766 keV peak, other peaks (63, 92 and 1001 keV) from $^{234}Th-^{234}mPa$ decay series were also detected on spectroscopy, and that the measured half lives of the four peaks were very close to known half life of $^{234}Th-^{234}mPa$ decay series, which is 24.1 day. The measured gamma yield ratios of 766 keV peak to 1001 peak were very close to known ratio 0.35 for $^{234}mPa$. It is concluded that 766 keV peaks on gamma spectroscopy of Ulchin NPP environmental samples were mainly from $^{234}mPa$, which is one of naturally occurring radionuclides.

고추가루 미생물의 방사선 감수성

  • 최언호;김영배;이서래
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1976.10a
    • /
    • pp.187.2-187
    • /
    • 1976
  • 시판 고추가루에서 미생물을 분리하여 세균 5종과 곰팡이 13종을 동정하였고 코발트-60 감마선에 대한 이들 균주의 치사율 (D$_{10}$ 값)을 조사하였다. 또한 고추가루에 0-1,000 krad의 감마선을 처리하고 저장중 미생물의 증식여부를 관찰한 결과 세균의 발육감소를 가져왔다.

  • PDF

청국장과 된장의 생리활성효과에 미치는 감마선의 영향

  • 손준호
    • Food Industry
    • /
    • s.168
    • /
    • pp.28-31
    • /
    • 2002
  • 한국산 콩 발효식품인 청국장과 된장의 생리활성효과에 대한 감마선의 영향을 살펴보았다. 청국장과 된장은 시중에서 구입하였으며 5,10,20 kGy의 선량으로 조사하였다. 생리활성효과로 angiotensin converting enzyme inhibition, xanthine oxidase inhibition, tyrosinase inhibition과 전자공여능을 살펴본 결과 10 kGy 보다 낮은 조사선량에서는 어떠한 영향도 끼치지 않는 것으로 나타났다.

  • PDF