• Title/Summary/Keyword: 감마 지표

Search Result 86, Processing Time 0.025 seconds

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

Hydrochemistry and Occurrences of Natural Radioactive Materials from Groundwater in Various Geological Environment (다양한 지질환경에서 지하수의 수리화학 및 자연방사성물질 산출특성)

  • Jeong, Chan Ho;Lee, Yu Jin;Lee, Yong Cheon;Kim, Moon Su;Kim, Hyun Koo;Kim, Tae Seong;Jo, Byung Uk;Choi, Hyeon Young
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.531-549
    • /
    • 2016
  • The purpose of this study is to analyze the relationship of hydrochemistry, geology, fault with occurrence of uranium and radon-222 from the groundwater in the Yeongdong area. In this study, 49 groundwater and 4 surface water samples collected in the study area were collected on two separate occasions. The surface radioactivities were measured at 40 points to know the relationship between the occurrence of uranium in groundwater and surface geology. The chemical composition of groundwater showed three types : $Ca-HCO_3$, $Na-HCO_3$ and $Ca-HCO_3(SO_4,\;NO_3)$. Two groundwater of 49 samples exceeded the maximum contaminant levels of uranium, $30{\mu}g/L$, proposed by the Ministry of Environment of Korea and 11 groundwater of 40 samples for Rn-222 concentrations exceeded the 148 Bq/L maximum contaminant level of US EPA. Most of unsuitable groundwater are located in the geological boundary related with the biotite gneiss and the surface radioactivities of rock samples showed no relationship with groundwater geochemical constituents. The strike-slip fault, Youngdong fault, is $N45^{\circ}E$ direction and the high concentrations of uranium in upper part of fault, consisted of granite and granitic gneiss are detected but in lower part, consisted of metamorphic sedimentary rock are not detected. It suggests that the natural radioactive concentrations are related with the geologic characteristics and the migration and diffusion of natural radioactive materials are affected by the fault.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Long-Term Trend Analysis in Nuclear Medicine Examinations (핵의학 영상 검사의 중장기 추세 분석 - 서울 소재 일개 상급 종합병원을 중심으로 -)

  • Jung, Woo-Young;Shim, Dong-Oh;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.15-28
    • /
    • 2019
  • Purpose Nuclear medicine was initially introduced in Korea in 1969 and widely applied to treat hyperthyroidism with $^{131}I$. Also, gamma camera was adopted in 1969 in the first place and its application has been growing continually in many ways. We analyzed long-term trend in nuclear medicine examinations for the last 2 decades. The purpose of this paper is to make predictions and to set both plans and directions on the development of nuclear medicine. Materials and Methods We analyzed the performance of nuclear medicine examinations and therapies performed in Asan Medical Center from 1998 to 2017. Results Results from the last 20 years regarding Bone scan, Renal scan, MUGA scan and $^{18}F$-FPCIT, Bone Mineral Density were on a increase. And Myocardium perfusion SPECT, Thyroid scan, Lung scan were on a decrease while $^{18}F-FDG$ PET maintained on a steady course. Until 2010 there was a positive performance with the therapy but after the excessive medical care in thyroid examination performance is at status quo. Key events such as a medical strike(2000), Middle-East Respiratory Syndrome (2015) influenced the overall performance of the therapy. Conclusion In order to promote a long-term growth in nuclear medicine examination and therapy, it is inevitable to respond to the changes in current medical environment. Furthermore, it is strongly suggested to put efforts to maintain and develop new examinations and clinical indicators.

A Study on the Biological Activity of Allium cepa Extract in Vivo (양파 추출물의 in vivo 생리활성에 관한 연구)

  • Lee, Jin Young
    • Journal of Life Science
    • /
    • v.30 no.3
    • /
    • pp.267-277
    • /
    • 2020
  • This study was conducted to assess the effect of highly concentrated onion intake on rodents. The experimental animals were divided two groups as follows; water administered group (CON) and Allium cepa administered group (ACE). The ACE group showed a slightly increases in the number of erythrocytes (RBC), hemoglobin (HGB), hematocrit (Hct) levels compared to the control group (p<0.05). Hemoglobin, monocyte, lymphocyte and neutrophil had no significant change (p>0.05) in ACE group and control group. The analysis of glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase (GPT) levels showed a significant decrease in ACE group compared to the control group (p<0.05). The blood glucose, total protein, HDL-cholesterol were slightly high in ACE group, while triglyceride, total cholesterol levels were lower in ACE group compared to the control group (p<0.05). The levels of cytokines (interluekin-1α (IL-1α), interleukin-1β (IL-1β), tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), interleukin-10 (IL-10), interferon-γ (INF-γ), interleukin-18 (IL-18), interleukin-2 (IL-2), granulocyte-macrophage colony-stimulating factor (GM-CSF)) involved in immunity and inflammation in liver tissue and blood have all been confirmed to be within normal range. These findings could be used as basic data to show that highly concentrated dietary onion extract is not toxic to hematological indicators and immune functions.

Post-irradiation Changes in Antioxidant Activity of Spindle Tree Leaves from Different Areas (서식지에 따른 사철나무 잎의 이온화 방사선 조사 후 항산화 활성 변화 차이)

  • Kim, Jin-Kyu;Cha, Min-Kyoung;Wilhelmova, Nad'a;Mukherjee, Anita
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.4
    • /
    • pp.280-285
    • /
    • 2011
  • As the plants grow in a fixed place, they can be a good indicator which reflects the level of environmental pollution. It is necessary for them to develop a strategy to cope with stress under unfavorable environmental conditions. In this study, spindle trees ($Euonymus$ $japonica$) were collected from a clean area (Kijang) as well as a heavily polluted area (Onsan) to check applicability of irradiation combined with plant bioassay to environmental monitoring. The leaves were irradiated with 0, 50 and 100 Gy of gamma rays, and then evaluated for antioxidative capacity with 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay and superoxide dismutase (SOD) analysis. The result shows that there was no significant changes in SOD and EDA (Electron Donationg Ability) in the samples collected from a polluted area. In the meanwhile, SOD increased in the samples from a clean area until 6 to 10 hours after irradiation, then it decreased gradually until 24 hours after irradiation. In conclusion, the plants in the polluted area have developed higher resistance to oxidative stress induced by ionizing radiation than those in the relatively clean area. Irradiation combined with plant bioassay on enzymatic activities and free radical scavenging capacity has proven to be a possible tool for biomonitoring the environmental pollution.

Electroencephalography Activities Influenced by Classroom Smells of Male High School (남자고등학교 교실냄새에 대한 뇌파반응)

  • Ryu, Hyun;Ko, WooHyong;Kim, JongWoo;Kim, SooRin;Kim, Min Kyung
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.387-396
    • /
    • 2013
  • In this study, the influence of classroom smells (foot odor, hair smell, sour smell, and sweat smell) of male high school and sweat smell and the offensive odor substance (ammonia and butyric acid) on the electroencephalography (EEG) activities of 20 female volunteers, ranging in age from 30 to 50 were studied. The representative response of brainwave index by these smells stimuli was most pronounced on temporal lobes among the brain lobes. By comparison with background EEG activities on temporal lobes, the smells reduced the relative alpha band power (0.04~0.13) and increased the relative beta band power (0.02~0.06) and the relative gamma band power (0.03~0.09). The alpha wave was deactivated, high beta (18~30Hz) and gamma (30~50Hz) waves were remarkably activated. The order of EEG fluctuation caused by the smell stimulus is as follows; hair smell > butyric acid > foot odor, sour smell > ammonia > sweat smell. It means that the classroom smells cause an excessive brain arousal and straining and may be reducing one's attention and learning ability.

  • PDF

Association of Coronary Artery Calcium Scores with Cadiovascular Disease Risk Factors in an Asymptomatic Adults (무증상 성인에서 심혈관질환 위험요소와 관상동맥 석회 수치와의 관계)

  • Moon, Il-Bong;Sohn, Seok-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.268-275
    • /
    • 2010
  • Coronary artery calcium scores(CACS) has been used as surrogate marker for coronary atherosclerosis. We evaluated 1042 patients who visited the Department of Health Promotion Center in Chonnam National University Hospital and had a test of the CACS from January 2006, to December 2008. This study was performed to evaluate the relation of the CACS with Cadiovascular disease(CVD) risk factors and FRS. CACS and FRS was a significant difference between the group whose calcium score was 0 and the group whose calcium scores were 1 in case of men 2.38(95% CI, 1.83-3.11), women 2.12(95% CI, 1.03-4.35). The age-and sex-adjusted odds ratios for predictor of CVD risk factors to women with age was 1.10(95% CI, 1.06-1.15), HDL-cholesterol was 2.38(95% CI, 1.04-5.44), Fasting plasma glucose was 2.89(95% CI, 1.16-7.21), to men with age was 1.11(95% CI, 1.08-1.14), LDL-cholesterol was 2.12(95% CI, 1.28-3.50), gamma-GTP was 1.73(95% CI, 1.17-2.55), Diabetes mellitus medication was 3.92(95% CI, 1.73-8.89). The CACS seems to be a siginificant factor to evaluate the CVD risk factors.

Correlation of Executive Function and Quantitative Electroencephalography in Children and Adolescents with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 소아청소년의 실행기능과 정량화 뇌파의 상관성 연구)

  • Jeong, Yu-jin;Park, Jin Young;Kim, Hyunjung;Choi, Jungwon;Jhung, Kyungun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • Objectives : Attention-deficit hyperactivity disorder(ADHD) is characterized by significant impairments in executive functions, with a prevalence of approximately 3-5% of all children worldwide. The goal of this study was to examine the relationship between executive functions and electrophysiological activities in children and adolescents with ADHD. Methods : In 31 patients with ADHD, resting-state EEG was recorded, and Comprehensive Attention Test(CAT), Stroop Color-Word Inference Test(Stroop CWIT), Trail Making Test(TMT), and Wisconsin Card Sorting Test(CST) were administered. Korean version of the ADHD Rating Scale(K-ARS) was assessed. Results : Alpha and beta power positively correlated with the Attention Quotient(AQ), while delta power negatively correlated with AQ from CAT. In the Stroop CWIT, decreased delta power and increased beta power were related to higher performance. Power of the alpha band increased with higher TMT performance. Moreover, delta power negatively correlated with good performance on the CST, while alpha and high gamma band showed a positive correlation. Correlation with the parent-rating of ADHD symptoms showed a negative correlation between alpha power and higher scores on the K-ARS. Conclusions : These findings indicate that relative power in higher frequency bands of EEG is related to the higher executive function in children and adolescents with ADHD, while the association with the relative power in lower frequency bands of EEG seem to be vice versa. Furthermore, the findings suggest that QEEG may be a useful adjunctive tool in assessing patients with ADHD.

Evaluation of Image Quality by Parameter Change in Onco Flash (Onco Flash에서 매개변수 변화에 따른 영상의 질 평가)

  • Cha, Eun-Sun;Noh, Ik-Sang;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.30-34
    • /
    • 2009
  • Purpose: Many companies developed a lot of programs with continuous effort for program upgrading. With this acquire superior image quality for the purpose of quick examination and progress in spatial resolution. This study was to obtained clinical usefulness on a appropriate parameter of FWHM for speed and alpha value for superior image quality. Materials and Methods: Gamma camera by Siemens (e.cam) and spatial resolution phantom and four quadrant bar phantom used. Compared for FWHM by changed scan speed 15, 20, 25, 30, 35, 40 cm/min in scatter and non scatter in Onco Flash of spatial resolution phantom. Visual evaluation of count rate and bar phantom image for increased of alpha value of 10% in 0~100%. Results: FWHM by the scan speed was 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm in the scatter. Count rate increased alpha value 10% increased. Visual evaluation was suitable to below 30%, Therefore spatial resolution improved on FWHM at the scan speed 25~35 cm/min applying for alpha value 30% in Onco Flash was average 9.3 mm less than FWHM of below 15 cm/min and above 40 cm/min. Conclusion: We found on appropriate parameter to progress of image quality. And there be a useful guideline for you that appropriate scan speed on vary in parameters of reduction on examination time and advancing image quality.

  • PDF