• Title/Summary/Keyword: 감마방사선

Search Result 992, Processing Time 0.031 seconds

Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy (토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.201-207
    • /
    • 2015
  • The new function of 3DVH software for dose calculation inside the patient undergoing TomoTherapy treatment by applying the measured data obtained by ArcCHECK was recently released. In this study, the dosimetric accuracy of 3DVH for the TomoTherapy DQA process was evaluated by the comparison of measured dose distribution with the dose calculated using 3DVH. The 2D diode detector array MapCHECK phantom was used for the TomoTherapy planning of virtual patient and for the measurement of the compared dose. The average pass rate of gamma evaluation between the measured dose in the MapCHECK phantom and the recalculated dose in 3DVH was $92.6{\pm}3.5%$, and the error was greater than the average pass rate, $99.0{\pm}1.2%$, in the gamma evaluation results with the dose calculated in TomoTherapy planning system. The error was also greater than that in the gamma evaluation results in the RapidArc analysis, which showed the average pass rate of $99.3{\pm}0.9%$. The evaluated accuracy of 3DVH software for TomoTherapy DQA process in this study seemed to have some uncertainty for the clinical use. It is recommended to perform a proper analysis before using the 3DVH software for dose recalculation of the patient in the TomoTherapy DQA process considering the initial application stage in clinical use.

Image-Based Assessment and Clinical Significance of Absorbed Radiation Dose to Tumor in Repeated High-Dose $^{131}I$ Anti-CD20 Monoclonal Antibody (Rituximab) Radioimmunotherapy for Non-Hodgkin's Lymphoma (반복적인 $^{131}I$ rituximab 방사면역치료를 시행 받은 비호지킨 림프종 환자 군에서 종양 부위의 영상기반 방사선 흡수선량 평가와 임상적 의의)

  • Byun, Byung-Hyun;Kim, Kyeong-Min;Woo, Sang-Keun;Choi, Tae-Hyun;Kang, Hye-Jin;Oh, Dong-Hyun;Kim, Byeong-Il;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.60-71
    • /
    • 2009
  • Purpose: We assessed the absorbed dose to the tumor ($Dose_{tumor}$) by using pretreatment FDG-PET and whole-body (WB) planar images in repeated radioimmunotherapy (RIT) with $^{131}I$ rituximab for NHL. Materials and Methods: Patients with NHL (n=4) were administered a therapeutic dose of $^{131}I$ rituximab. Serial WB planar images alter RIT were acquired and overlaid to the coronal maximum intensity projection (MIP) PET image before RIT. On registered MIP PET and WB planar images, 2D-ROls were drawn on the region of tumor (n=7) and left medial thigh as background, and $Dose_{tumor}$ was calculated. The correlation between $Dose_{tumor}$ and the CT-based tumor volume change alter RIT was analyzed. The differences of $Dose_{tumor}$ and the tumor volume change according to the number of RIT were also assessed. Results: The values of absorbed dose were $397.7{\pm}646.2cGy$ ($53.0{\sim}2853.0cGy$). The values of CT-based tumor volume were $11.3{\pm}9.1\;cc$ ($2.9{\sim}34.2cc$), and the % changes of tumor volume before and alter RIT were $-29.8{\pm}44.3%$ ($-100.0%{\sim}+42.5%$), respectively. $Dose_{tumor}$ and the tumor volume change did not show the linear relationship (p>0.05). $Dose_{tumor}$ and the tumor volume change did not correlate with the number of repeated administration (p>0.05). Conclusion: We could determine the position and contour of viable tumor by MIP PET image. And, registration of PET and gamma camera images was possible to estimate the quantitative values of absorbed dose to tumor.

Isolation and Characterization of a Novel Flavonoid 3'-Hydroxylase (F3'H) Gene from a Chrysanthemum (Dendranthema grandiflorum) and Its Gamma-ray Irradiated Mutants (감마선 처리에 의한 스프레이형 국화 화색변이체로부터 Flavonoid 3'-Hydroxylase(F3'H) 유전자의 분리 및 특성 구명)

  • Chung, Sung-Jin;Lee, Geung-Joo;Kim, Jin-Baek;Kim, Dong-Sub;Kim, Sang-Hoon;Kang, Si-Yong
    • Horticultural Science & Technology
    • /
    • v.30 no.2
    • /
    • pp.162-170
    • /
    • 2012
  • The objectives of this study were to isolate and the sequence of novel $F3'H$ gene related to an anthocyanin pathway, and to confirm the expression patterns of the gene involved in the flower color variations of chrysanthemum mutants. In this study, we isolated the full-length cDNAs and the genomic DNAs of an $F3'H$ gene from a wild type (WT) chrysanthemum (cv. Argus) and its three color mutants. The sequence analysis revealed a putative open reading frame of 1,527 bp that encodes a polypeptide of 509 amino acids. Sequence homology ranged from 97% to 99% between 'Argus' and its three color mutants. The sequence analysis from the genomic DNA revealed that the chrysanthemum $DgF3'H$ gene consisted of three exons and two introns spanning a 3,830 bp length. The sizes of the gene for three mutants ranged from a shorter size of 3,828 bp to a longer size of 3,838 bp when compared to the size of WT. The total size of the two introns was 2,157 bp for WT, but those for three color mutants ranged from 2,154 bp to 2,159 bp. A result of an RT-PCR analysis indicated that the color variations of the mutants AM1 and AM2 can be partly explained by the structural modification derived from the sequencial changes in the gene caused by gamma ray. A Southern blot analysis revealed that the $DgF3'H$ gene existing as multiple copies in the chrysanthemum genome. A systemic study will be further needed to provide a genetic mechanism responsible for the color mutation and to uncover any involvement of genetic elements for the expression of the $DgF3'H$ gene for the color variation in chrysanthemum.

Dosimetric Characteristics of a Thermal Neutron Beam Facility for Neutron Capture Therapy at HANARO Reactor (하나로 원자로 BNCT 열중성자 조사장치에 대한 선량특성연구)

  • Lee, Dong-Han;Suh, So-Heigh;Ji, Young-Hoon;Choi, Moon-Sik;Park, Jae-Hong;Kim, Kum-Bae;Yoo, Seung-Yul;Kim, Myong-Seop;Lee, Byung-Chul;Chun, Ki-Jung;Cho, Jae-Won;Kim, Mi-Sook
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • A thermal neutron beam facility utilizing a typical tangential beam port for Neutron Capture Therapy was installed at the HANARO, 30 MW multi-purpose research reactor. Mixed beams with different physical characteristics and relative biological effectiveness would be emitted from the BNCT irradiation facility, so a quantitative analysis of each component of the mixed beams should be performed to determine the accurate delivered dose. Thus, various techniques were applied including the use of activation foils, TLDs and ionization chambers. All the dose measurements were perform ed with the water phantom filled with distilled water. The results of the measurement were compared with MCNP4B calculation. The thermal neutron fluxes were $1.02E9n/cm^2{\cdot}s\;and\;6.07E8n/cm^2{\cdot}s$ at 10 and 20 mm depth respectively, and the fast neutron dose rate was insignificant as 0.11 Gy/hr at 10 mm depth in water The gamma-ray dose rate was 5.10 Gy/hr at 20 mm depth in water Good agreement within 5%, has been obtained between the measured dose and the calculated dose using MCNP for neutron and gamma component and discrepancy with 14% for fast neutron flux Considering the difficulty of neutron detection, the current study support the reliability of these results and confirmed the suitability of the thermal neutron beam as a dosimetric data for BNCT clinical trials.

  • PDF

F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET (종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교)

  • Pai, Moon-Sun;Park, Chan-H.;Joh, Chul-Woo;Yoon, Seok-Nam;Yang, Seung-Dae;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.65-75
    • /
    • 1999
  • Purpose: The aim of this study is to demonstrate the feasibility of 2-[fluorine-18] fluoro-2-deoxy-D-glucose (F-18-FDG) whole body scan (FDG W/B Scan) using dual-head gamma camera equipped with ultra high energy collimator in patients with various cancers, and compare the results with those of coincidence imaging. Materials and Methods: Phantom studies of planar imaging with ultra high energy and coincidence tomography (FDG CoDe PET) were performed. Fourteen patients with known or suspected malignancy were examined. F-18-FDG whole body scan was performed using dual-head gamma camera with high energy (511 keV) collimators and regional FDG CoDe PET immediately followed it Radiological, clinical follow up and histologic results were correlated with F-18-FDG findings. Results: Planar phantom study showed 13.1 mm spatial resolution at 10 cm with a sensitivity of 2638 cpm/MBq/ml. In coincidence PET, spatial resolution was 7.49 mm and sensitivity was 5351 cpm/MBq/ml. Eight out of 14 patients showed hypermetabolic sites in primary or metastatic tumors in FDG CoDe PET. The lesions showing no hypermetabolic uptake of FDG in both methods were all less than 1 cm except one lesion of 2 cm sized metastatic lymph node. The metastatic lymph nodes of positive FDG uptake were more than 1.5 cm in size or conglomerated lesions of lymph nodes less than 1cm in size. FDG W/B scan showed similar results but had additional false positive and false negative cases. FDG W/B scan could not visualize liver metastasis in one case that showed multiple metastatic sites in FDG CoDe PET. Conclusion: FDG W/B scan with specially designed collimators depicted some cancers and their metastatic sites, although it had a limitation in image quality compared to that of FDG CoDe PET. This study suggests that F-18-FDG positron imaging using dual-head gamma camera is feasible in oncology and helpful if it should be more available by regional distribution of FDG.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

A Study on Recovery from Potentially Lethal Damage Induced by $\gamma-Irradiation$ in Plateau-phase Vero Cells in vitro (평형기의 Vero세포계에서 방사선($\gamma$-선) 조사 후 발생한 잠재치사 손상의 회복에 관한 연구)

  • Kim, Il-Han;Choi, Eun-Kyung;Ha, Sung-Whan;Park, Charn-Il;Cha, Chang-Yong
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 1988
  • Recovery from potentially lethal damage (PLDR) after irradiation was studied in plateau-phase culture of Vero cells in vitro. Unfed plateau-phase cells were irradiated with dose of 1 to 9Gy using Cs-137 irradiator. Cells then were incubated again and left in situ for 0, 1, 2, 3, 4, 5, 6, and 24 hours and then were trypsinized explanted, and subcultured in fresh RPMI-1640 media containing $0.33\%$ agar. Cell survival was measured by colony forming ability. An adequate number of heavily irradiated Vero cells were added as feeder cells to make the total cell number constant in every culture dish. As the postirradiation in situ incubation time increased, surviving fraction increased by PLDR. The rate of PLDR was so rapid that increased surviving fraction reached saturation level at 2 to 4 hours after in situ incubation. As the radiation dose increased, the rate of PLDR fastened and the magnitude of increased surviving fraction at saturation level by PLOR also increased. In analysis of cell survival curve fitted to the linear-quadratic model, the linear inactivation coefficient $(\alpha)$ decreased largely and reached nearly to zero but the quadratic inactivation coefficient $(\beta)$ increased minimally by increment of postirradiation in situ incubation time. So PLDR mainly affected the damage expressed as $\alpha$, In the multitarget model, significant change was not obtained in $D_0\;but\;in D_q$. Therefore, shoulder region in cell survival curve was mainly affected by PLDR and terminal slope was not influenced at all. And dose-modifying factor by PLDR was relatively higher in shoulder region, that is, in low dose area below 3 Gy.

  • PDF

Effects of Gamma Irradiation and Ethylene Oxide Fumigation for the Quality Preservation of Spices and Dry Vegetables (건조향신 조미식품의 품질보존을 위한 효과적인 살균방법에 관한 비교연구)

  • 신광순;마점술;조종후
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.119-132
    • /
    • 1989
  • Gamma irradiation as a new physical treatment was applied to comparative investigates with a conventional ethylene oxide fumigant on the microbiological and physicochemical qualities of selected spices and dry vegetables such as powdered red pepper, black pepper, welsh onion, onion, garlic, carrot, korean cabbage and instant ramyon soup. The microorganisms contaminated in the sample, including total viable count, thermophilic bacteria, aerobic spore and fungi counts between the $10^4\;to\;10^6/g$ range. Coliforms were found only in black pepper and welsh onion powder as the $10^2\;to\;10^3/g$ level. A radiation dose of 7 to 10 KGy were sterilized completely to the contaminated microorganisms, while ehthylene oxide (E.O.) fumigation reduced of them to the $10^3/g$ level. An optimum dose of irradiation was less detrimental than E.O. fumigation to the physicochemical properties of the sample. Sensory evaluation after three months of storage at room temperatures showed that the overall acceptability of irradiated sample was higher than that of the non treated control as well as E.O. fumigated samples. Comparison gamma irradiation with E.O. gas treatment showed that E.O. treatment was less effective than radiation in cotrolling microbial contamination of spices and vegetables.

  • PDF

Batch Scale Storage of Sprouting Foods by Irradiation Combined with Natural Low Temperature - III. Storage of Onions - (방사선조사(放射線照射)와 자연저온(自然低溫)에 의한 발아식품(發芽食品)의 Batch Scale 저장(貯藏)에 관한 연구(硏究) - 제3보(第三報) 양파의 저장(貯藏) -)

  • Cho, Han-Ok;Kwon, Joong-Ho;Byun, Myung-Woo;Yang, Ho-Sook
    • Applied Biological Chemistry
    • /
    • v.26 no.2
    • /
    • pp.82-89
    • /
    • 1983
  • In order to develop a commercial storage method of onions by irradiation combined with natural low temperature, two local varieties of onions, precocious species and late ripening, were stored at natural low temperature storage room ($450{\times}650{\times}250cmH.$; year-round temperature change, $2{\sim}17^{\circ}C$; R.H., $80{\sim}85%$) on batch scale following irradiation with optimum dose level. Precocious and late varieties were all sprouted after five to seven months storage, whereas $10{\sim}15$ Krad irradiated precocious variety was $2{\sim}4%$ sprouted after nine months storage, but sprouting was completly inhibited at the same dose for late variety. The extent of loss due to rot attack after ten months storage were $23{\sim}49%$ in both control and irradiated group of precocious variety but those of late variety were only $4{\sim}10%$. The weight loss of irradiated precocious variety after ten months storage was $13{\sim}16$, while that of late variety was $5.3{\sim}5.9%$ after nine months storage. The moisture content, during whole storage period, of two varieties were $90{\sim}93$ with negligible changes. The total sugar content differed little with varieties and doses immediatly after irradiation, but decreased by the elapse of storage period. 33.6% of its content was decreased in control and 12.5% in irradiated group but $20{\sim}26$ decreased in both control and irradiated group of late variety after nine months storage. No appreciable change was observed immediately after irradiation irrespective of variety and dose, but decreased slightly with storage. Ascorbic acid content of precocious variety was increased slightly with dose immediately after irradiation, but those of late variety decreased slightly. Ascorbic acid content were generally decreased during whole storage period. An economical preservation method of onions appliable to late variety, would be to irradiate onion bulbs at dost range of $10{\sim}15$ Krad followed by storage at natural low temperature storage room.

  • PDF