• Title/Summary/Keyword: 감도계산

Search Result 145, Processing Time 0.021 seconds

The ATC Calculation Method with Thermal Constraints and Voltage Stability Constraints (열적용량과 전압안정도를 고려한 ATC 계산 방법에 관한 연구)

  • Gim, Jae-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • This paper proposes two fast calculation methods of ATC. These two methods evaluate ATC with thermal constraints(Thermal ATC) and ATC with voltage stability constraints(Voltage ATC) respectively. The ATC with thermal constraints was based on the linear incremental power flow to account for the line flow thermal loading effects when the n-1 security constraints were included. The ATC with voltage stability constraints used two-bus equivalents of the system to find the maximum load at a load bus before reaching the voltage stability problem. The methods were tested on the IEEE 30bus systems and the results obtained were compared with those found by some other methods.

Feasibility Study of the Real-Time IMRT Dosimetry Using a Scintillation Screen (고감도 형광판을 이용한 실시간 선량측정 가능성 연구)

  • Lim Sang Wook;Yi Byong Yong;Ko Young Eun;Ji Young Hoon;Kim Jong Hoon;Ahn Seung Do;Lee Sang Wook;Shin Seong Soo;Kwon Soo-Il;Choi Eun Kyoung
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • Purpose : To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. Materials and Methods : The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom In order to capture the visible light from the scintillation screen. To observe the dose distribution In real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the Intensity modulated radiation therapy (IMRT). Results : The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. Conclusion : Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.

Effects of Main Engine Bearing Number on the Bearing Reactions of the Propulsion (메인엔진 베어링 수가 축계 베어링 반력에 미치는 영향)

  • Lee, Heon-Kwon;Lee, Yong-Jin;Kim, Ue-Kan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.5-6
    • /
    • 2006
  • 대형 저속 2행정기관을 탑재한 선박에서 축계배치와 관련된 선미측 후부 메인엔진 베어링의 손상이 증가하는 경향이 있다. 메인엔진을 포함한 선체는 최적화로 인하여 변형하기 쉬운 경향에 있고, 고출력을 요구하는 추진 축계는 이것과 반대의 경향을 가지므로 축계 배치 변화에 대한 감도가 높아져서 메인엔진 베어링의 손상이 발생하게 된다. 이러한 문제에 대한 대책으로 메인엔진 베어링을 포함한 보다 정확한 배치계산을 할 필요가 있다. 이 논문에서는 축계배치계산 고정도화의 일환으로 메인엔진 베어링 수가 베어링 반력에 미치는 영향에 대하여 검토한다.

  • PDF

Measurements and Statistical Modeling of Man-made Noise (인위적인 전자파 잡음의 측정 및 통계적 모형)

  • 김종호;우종우;백락준;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.159-170
    • /
    • 1998
  • Man-made noise in PCS frequency range are measured using the three axis antennal with common port and the measured data are statistically treated for modeling. The can optimal parameters of the measured APD curves can be calculated fast by using the Composite Approximation Algorithm. The calculated APD parameters can reduce the EM-environments Data Base memory and also be applied to determine the output and sensitivity margin of the transmitter and the receiver.

  • PDF

An Eigenvalue Sensitivity Analysis of the Iterative Eigenvalue Calculation Algorithm (반복계산에 의한 고유치 계산 알고리즘에서의 고유치 감도해석)

  • Kim, Deok-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.217-219
    • /
    • 2001
  • This paper presents a new eigenvalue sensitivity analysis method based on AESOPS algorithm. The additional calculation steps are derived from the original AESOPS algorithm. The additional calculation steps are performed directly from the AESOPS algorithm after iteratively calculating electro-mechanical oscillation modes in small signal stability problems. Owing to the structural characteristics of partitioned sub-matrix of state space equations, the partial differentiation terms of system state matrix for obtaining eigenvalue sensitivity indices can be calculated very simply. By the method presented in this paper, the AESOPS algorithm can be used in controller design problem as well as analysis of small signal stability problem.

  • PDF

A New Algorithm for Contingency Analysis (새로운 상정사고 해석 알고리)

  • 박영문;김재철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.232-240
    • /
    • 1984
  • This paper presents a new algorithm for power system contingency analysis and sensitivity matrix associated with the contingency measures. The algorithm has several advantages over conventional ones in terms of both accuracy and time of computation by improving base A.C. load flow calculation scheme, contingency evaluaiton formula based on a variable slack generating power concept and transmission loss formula. The algorithm was tested for the 5-bus system and 24-bus IEEE Reliability Test system with satisfactory results.

  • PDF

Fast Contingency Ranking Algorithm of Power Equipment (전력설비의 신속한 상정사고 선택 앨고리즘)

  • 박규홍;정재길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 1998
  • This paper presents an algorithm for contingency ranking using line outage distribution factors(LODF) which are established by generation shift distribution factors(GSDF) from DC load flow solutions. By using the LODF, the line flow can be calculated according to the modification of base load flow if the contingency occur. To obtain faster contingency ranking, only the loading line more than 35[%](60[%] at 154[kV]) is included in the computation of Performance Index(PI). The proposed algorithm has been validated in tests on a 6-bus test system.system.

  • PDF

A case study on the optimal shafting alignment concerning bearing stiffness for 10,100 TEU container carrier (베어링 강성을 고려한 10,100 TEU 컨테이너 운반선의 최적 추진축계 배치에 관한 사례 연구)

  • Lee, Jae-Ung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Damages of the main engine aftmost bearing and the after stern tube bearing tend to increase due to misalignment. And as the shafting system becomes stiffer due to the large engine power, whereas the hull structure becomes more flexible due to optimization by using high tensile thin steel plates. And this is the reason that more sophisticated shaft alignments are required. In this study, the optimum shafting alignment calculation was carried out, considering the thermal expansion effect, exploiting the sensitivity index, which indicates the reasonable position of forward intermediate shaft bearing for shaft alignment. and as the main subject in this study, the elastic deformation on intermediate shaft and main engine bearings occurred by vertical load of shaft mass were examined thoroughly and analyzed allowable load of bearings, reaction influence numbers of all bearings. As the result, a reliable optimum shafting alignment was derived theoretically. To verify these results, they were referred to the engine maker's technical information of main engine installation and being used shafting alignment programs of both Korean Register of Shipping and Det Norske Veritas, their reliability were reviewed.

A study on the changes of the noise reception sensitivity in the optical system (광시스템의 잡음에 따른 수신감도 변화에 관한 연구)

  • Ra, Yoo-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.677-682
    • /
    • 2015
  • In this paper, we investigated the effect of light on the performance of the receiver system noise and external noise added from the ever-present influence in general optical system. And calculated the reception sensitivity of the receiver at the time of off-keying transmission - from the optical transmission system in consideration of the case that the photo detector has a quantum yield of less than one-one. Not less than 50 it was confirmed that it is possible to configure the low power system is calculated and compared with the case where less than 300 the receiver sensitivity of the optical system to maintain the standard error probability. However, even if these values were considered, and the preamplifier in the receiver, considering a case of using a low-output light source, so that a heavy burden in the value less than the actual system installation, using the light source having less than the output, as shown in Figure 3, the results that were obtained also may be used.

Electrical Resistivity Methods in Korea (한국의 전기비저항탐사)

  • Kim, Hee-Joon
    • Economic and Environmental Geology
    • /
    • v.39 no.4 s.179
    • /
    • pp.473-483
    • /
    • 2006
  • Although application of electrical methods in Korea began with observation of self potentials before World War II, the methods were developed slowly by the beginning of 1980's when a major burst of development activity took place. DC resistivity methods are applied in Korea more to geotechnical problems rather than to environmental ones unlike other developed countries. As with every other branch of technology, the evolving speed of the silicon chip and of streaming data to hard disk has revolutionized data collection and noise reduction processing. The last two decades saw major advances in data collection, processing, and interpretation of electrical data. Development of smooth-model two-dimensional (2D) resistivity inversion is one of the most visible changes to geophysical interpretation of the last 40 years and is now routinely applied to apparent resistivity data. The ability to represent resistivities in section rather than pseudosection view has revolutionized interpretation. Although calculation of sensitivities for general electromagnetic problems require numerous forward modelings, DC resistivity methods can enjoy computational efficiencies if sources and receivers occupy the same position, and previously intractable 3D inversion is now becoming available.