• Title/Summary/Keyword: 감도계산

Search Result 145, Processing Time 0.021 seconds

Construction of Inverse Photoemission Spectrometer and Its Application (역광전자분광기의 제작 및 그 응용)

  • Kim, Jeong-Won;Kim, Se-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.12
    • /
    • pp.719-723
    • /
    • 1996
  • An inverse photoemission spectrometer has been built and tested to study the unoccupied electron energy states of solid surfaces. It consists of a low energy electron gun and a band pass photon detector in an ultra-high vacuum chamber. The electron ray tracing simulation and current measurement of the electron gun show a good focus and a high flux of electron current. The overall resolution of the spectrometer is 0.74 eV and the sensitivity of the photon detector is about 10 counts/$sec{\cdot}{\mu}A.$ As a test experiment, the inverse photoemission spectra of a Ge(111) sample is in good agreement with the theoretical result.

  • PDF

Temperature Property Analysis of Micro Flow Sensor using Thermal Transfer Equation (열운송 방정식을 이용한 마이크로 흐름센서의 온도특성 해석)

  • Kim, Tae-Yong;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.363-366
    • /
    • 2005
  • A micro flow sensor on silicon substrate allows the fabrication of small components where many different functions can be integrated so that the functionality of the sensors can be increased. Further more, due to the small size of the elements the sensors can be quite fast. A thermal mass flow sensor measures the asymmetry of temperature profile around the heater which is modulated by the fluid flow. In normal, a mass flow sensor is composed of a central heater and a pair of temperature sensing elements around the heater. A new 2-D wide range micro flow sensor structure with three pairs of temperature sensors and a central heater was proposed and numerically simulated by the Finite difference formulation to confirm the feasibility of the flow sensor structure.

  • PDF

Effective Ways of Performing Surveillance Surface Cultures in Extremely Low Birth Weight Infants

  • Lee, Ju-Young;Kim, Ee-Kyung;Lee, Jin-A;Choi, Chang-Won;Kim, Han-Suk;Kim, Beyong-Il;Choi, Jung-Hwan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2011
  • Purpose: The rationale for skin surface cultures is that bacterial colonization precedes infection and, as a result, that identification of a potential pathogen is predictive of later systemic infection in preterm infants. We aimed to analyze results of surveillance surface cultures in extremely low birth weight (ELBW) infants and seek for effective ways of performing surveillance surface cultures. Methods: We analyzed the surveillance surface cultures of 113 ELBW infants over a 4-year period. Surveillance cultures were obtained routinely from five sites: axilla, external ear canal, nasopharynx, throat (or tracheal aspirate if intubated) and anus. Each surface culture obtained during the 13 days, prior to the date of the blood culture, was compared with the blood culture obtained when sepsis was suspected. The sensitivity, specificity and positive predictive value (PPV) of the surveillance cultures were calculated among 1894 blood-surface culture pairs by surface sites, recovered organisms and interval between surveillance samples and blood cultures. Results: The overall sensitivity, specificity and PPV of surface cultures were 45.9, 22.4 and 6.8%, respectively. The PPV was highest for the throat/tracheal cultures (11.0%) and lowest for the anal cultures (2.3%). As the time of culturing progressed toward the day of blood culturing, the sensitivity and specificity of the surface cultures significantly increased. Only axillary and throat/tracheal cultures were useful in predicting the microorganisms causing sepsis. Conclusion: Surface cultures could help to predict sepsis pathogens and infection surveillance in preterm infants could be continued with a reduced number of cultured sites focusing on the axilla and throat/trachea.

Optoelectronic properties of the Metal-dielectric complex thin films for applying high sensitivity IR image sensors (고감도 적외선 이미지 센서 적용을 위한 금속-유전체 복합 박막의 광전자 특성)

  • Kim, Ye-Na;Kwon, Soon-Woo;Park, Seung-Jun;Kim, Woo-Kyug;Lee, Han-Young;Yoon, Dae-Ho;Yang, Woo-Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • High sensitivity IR image sensors require materials characteristics with temperature coefficient of resistance (TCR) and IR range absorption. In this study, the metal-dielectric thermo sensitive films (MDTF) based on $(SiO_2)_x-(Ti)_y$ composition were deposited on substrates of germanium and glass by thermal evaporator. The $SiO_2$ : Ti mixture was made from the ratio of 9 : 1, 8 : 2, 7 : 3, 6 : 4, respectively. $(SiO_2)_x-(Ti)_y$ mixture powder was loaded on tungsten boat in evaporator and was 15.5 cm from the substrate. Resistance of $(SiO_2)_x-(Ti)_y$ in the range of 273~333K were measured as a function of temperature. Temperature coefficient of resistance (TCR) was calculated by the resistance variation. Under the various mixture ratios condition, it is possible to obtain $SiO_2$-Ti layers with resistance from units kilo-ohm to hundreds kilo-ohm. Finally, our results showed that Temperature coefficient of resistance (TCR) of these films varies from -1.4 to $-2.6%K^{-1}$.

Temporal and Spatial Distributions of Solar Radiation with Surface Pyranometer Data in South Korea (일사 관측 자료에 의한 남한의 태양복사 시공간 분포)

  • Jee, Joon-Bum;Kim, Yeong-Do;Lee, Won-Hak;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.31 no.7
    • /
    • pp.720-737
    • /
    • 2010
  • This study is to analyze the temporal and spatial distributions of solar radiation in South Korea. Solar radiation data is observed every minute at 22 KMA (Korea Meteorological Administration) stations using pyranometer from January 2000 to August 2007. These data were calibrated using intensive comparative observation and solar radiation model. Intensive comparative observations are accomplished at 22 KMA stations between KNU (Kangnung (Gangneung-Wonju) National University) standard and station instruments during the month of August 2007. The solar radiation of a clear sky mainly is affected by precipitable water, solar altitude and geological height. Also old (raw) data is corrected by the solar radiation model only about clear day and is revised based on the temporal trend of instrument's sensitivity decrease. At all periods and all stations, differences between raw data (13.31 MJ/day) and corrected data (13.75 MJ/day) are 0.44 MJ/ day. So, the spatial distribution of solar radiation is calculated with seasonal and annual mean, and is the relationship with cloud amount is analyzed. The corrected data show a better consistency with the cloud amount than the old data.

Development of High-Sensitivity and Entry-Level Nuclide Analysis Module (고감도 보급형 핵종 분석 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.515-519
    • /
    • 2022
  • In this paper, we propose the development of a high-sensitivity entry-level nuclide analysis module. The proposed measurement sensor module consists of an electronic driving circuit for nuclide analysis resolution, prototype production with nuclide analysis function, and GUI development applied to prototypes. The electronic part driving circuit for nuclide analysis resolution is divided into nuclide analysis resolution process by the electronic part driving circuit block diagram, MCU circuit design used for radiation measurement, and PC program design for Spectrum acquisition. Prototyping with nuclide analysis function is made by adding a 128×128 pixel OLED display, three buttons for operation, a Li-ion battery, and a USB-C type port for charging the battery. The GUI development department applied to the prototype develops the screen composition such as the current time, elapsed measurement time, total count, and nuclide Spectrum. To evaluate the performance of the proposed measurement sensor module, an expert witness test was conducted. As a result of the test, it was confirmed that the calculated result by applying the resolution formula to the Spectrum (FWHM@662keV) obtained using the Cs-137 standard source in the nuclide analysis device had a resolution of 17.77%. Therefore, it was confirmed that the nuclide analysis resolution method proposed in this paper produces improved performance while being cheaper than the existing commercial nuclide analysis module.

Study on the method to evaluate performance of Light Collector in Light-collecting System (집광채광 설비 입사부의 성능 평가방법에 관한 연구)

  • Yoon, Yongsang;Mun, Sunhye
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.49.1-49.1
    • /
    • 2011
  • 집광채광 설비는 건축물의 조명에너지 절감 및 자연광의 실내 유입을 위해 적용 가능한 태양에너지설비로써 다른 신 재생 에너지 설비와 다르게 연간에너지생산에 대한 정량적 데이터가 아직까지 부재하다. 집광채광 설비의 설치효과를 판단하기 위해서는 집광채광 설비 설치에 따른 연간 에너지생산량 산출이 필요하며, 이를 위해서는 각 구성부분(집광부, 전송부 및 산광부)의 광전송 효율에 대한 데이터가 구축되어야 한다. 본 연구는 집광채광 설비의 효율 분석에 관한 첫 번째 단계로써 외부광속에 대한 집광부 통과 직후의 내부광속의 비율을 예측하였다. 국내에 보급된 집광채광 설비는 대부분 프리즘형과 광덕트형이며, 우선적으로 집광부 입사면의 경사각과 방위각이 다양하여 내부광속 산출방법론이 매우 복잡한 프리즘형을 분석대상으로 삼았다. 전일사량, 외부조도 및 집광부 내부조도가 측정되었으며, 외부광속으로부터 내부광속을 산출하는 공식을 유도하기 위해 천공상태에 따라 전일사량 측정치가 직산분리 되었다. Perez model과 Liu and Jordon에 의해 제시된 계산식과 입사면 및 집광부 면적을 고려하여 수평면 외부조도 측정치로부터 외부광속이 그리고 내부조도로부터 내부광속이 산출되었다. 입사면의 투과율이 동일하다는 전제 하에 천공상태에 따른 태양광 투과 비율을 도출한 결과, 담천공(Kt ${\leq}$ 0.3)에서 0.39, 부분담천공(0.3${\geq}$ 0.78)에서 1.0으로 나타났다. 도출된 투과비율을 외부광속에 적용하여 내부광속을 계산한 결과치와 측정치는 약 ${\pm}9%$ 정도의 차이를 보였다. 연간 기상데이터에 위와 같은 방법론이 적용되면 프리즘형 집광부의 연간 내부광속이 산출될 수 있다. 또한 기존 연구에서 제시된 발광효율 산출식과 일사 파장에 따른 시감도를 고려하면 매 시간별 외부조도도 산출이 가능하다. 일사량 측정치와 외부조도 측정치 사이의 상관관계를 분석한 결과 결정계수 $R^2$이 0.99인데 반해 일사량 측정치와 외부조도 계산치 사이의 상관관계 결정계수는 0.95로 측정치 보다 약간 작은 값을 갖는다. 이렇게 산출된 외부조도는 각 입사면의 면적을 반영하여 외부광속으로 변환되고, 앞서 산출된 천공상태별 투과비율이 적용됨으로써 내부광속이 도출될 수 있다. 이와 같은 집광부에 대한 연구를 바탕으로 향후 전송부와 산광부 효율을 도출하고 궁극적으로 집광채광 설비를 통해 실내에 전달되는 연간 빛에너지를 예측할 수 있을 것이다. 또한 본 연구의 방법론은 다른 형태의 집광채광 설비에도 적용이 가능할 것으로 판단되며, 국내 집광채광 설비의 연간 에너지생산량에 대한 폭 넓은 데이터 구축이 가능할 것으로 기대된다.

  • PDF

Vibration and Dynamic Sensitivity Analysis of a Timoshenko Beam-Column with Ends Elastically Restrained and Intermediate Constraints (중간구속조건을 갖는 양단탄성구속 Timoshenko 보-기동의 진동 및 동특성감도 해석)

  • J.H. Chung;W.H. Joo;K.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.1
    • /
    • pp.125-133
    • /
    • 1993
  • Most studies on the vibration analysis of a beam-column with ends elastically restrained and various intermediate constraints have been based on the Euler beam theory, which is inadequate for beam-columns of low slenderness ratios. In this paper, analytical methods for vibration and dynamic sensitivity of a Timoshenko beam-column with ends elastically restrained and various intermediate constraints are presented. Firstly, an exact solution method is shown. Since the exact method requires considerable computational effort, a Rayleigh-Ritz analysis is also investigated. In the latter two kinds of trial functions are examined for comparisions : eigenfunctions of the base system(the system without intermediate constraints) and polynomials having properties corresponding to the eigenfunctions of the base system. The results of some numerical Investigations show that the Rayleigh-Ritz analysis using the characteristic polynomials is competitive with the exact solutions in accuracy, and that it is much more efficient in computations than using the eigenfunctions of the base system, especially in the dynamic sensitivity analysis. In addition, the prediction of the changes of natural frequencies due to the changes of design variables based on the first order sensitivity is in good agreements with that by the ordinary reanalysis as long as the changes of design variables are moderate.

  • PDF

Thermal Stability of Israeli Carp Actomyosin and Its Protection by Chemical Additives (이스라엘 잉어 Actomyosin의 열안정성과 그 보호)

  • NAM Taek-Jeong;CHOI Yeung-Joon;PYEUN Jae-Hyeung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.4
    • /
    • pp.271-279
    • /
    • 1984
  • Effects of temperature and additives on the stability of actomyosin extracted from skeletal muscle of Israeli carp, Cyprinus carpio nudus, were studied by analyzing free SH-group, ATP-sensitivity and Ca-ATPase activity. The used additives were sucrose, sorbitol, Na-glutamate and L-cysteine. Furthermore, the denaturation constant($K_D$), protective effect(${\Delta}E/M$) and the other thermo-dynamic parameters on protein denaturation are systematically discussed. The actomyosin showed $4.12{\sim}4.68 mg/ml$ in protein concentration, $2.63{\sim}2.93\%$ in ribonucleic acid to the protein, $1:2.20{\sim}2.63$ in the binding ratio of myosin and actin, $4.33{\sim}5.26\%$ in fat content, 109.78 in ATP-sonsitivity, $0.159{\sim}0.201\;{\mu}M-Pi/min/mg-protein$ in Ca-ATPase activity and $3.3{\sim}3.4M/10^5$g-protein in free SH-group content. The first-order rate plots were obtained on the decrease of Ca-ATPase activity and ATP-sensitivity with an increase in temperature, while the free SH-group was increased to $60^{\circ}C$ and decreased rapidly above the temperature. The half-life of Ca-ATPase activity on the actomyosin Ca-ATPase was 280 min at $12^{\circ}C$, 125 min at $20^{\circ}C$, 55 min at $30^{\circ}C$ and 13 min at $40^{\circ}C$, and activation energy, activation enthalpy, activation entropy and free energy of the proteins at $20^{\circ}C$ wene 5,395 cal/mole, 4,814 cal/mole, -40.42 e.u. and 17,626 cal/mole, respectively. The protective effect of the additives on the actomyosin Ca-ATPase showed that the most effective material is $3\%$ sorbitol and followed in the order of $8\%$ Na-glutamate, $1\%$ sucrose and $1\%$ L-cysteine. The actomyosin was more stable at $-30^{\circ}C$ than at $0^{\circ}C$ and $-20^{\circ}C$. and when the additives were used in the low temperature storage, $8\%$ Na-glutamate was the most effective. $3\%$ sorbitol, $1\%$ sucrose and $1\%$ L-cysteine was to become lower in the order.

  • PDF

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF