• Title/Summary/Keyword: 간종양

Search Result 694, Processing Time 0.031 seconds

Immunoglobulin G4-Related Disease in the Thorax: Imaging Findings and Differential Diagnosis (흉부에서 발생한 IgG4 연관 질환: 영상 소견 및 감별진단)

  • Yookyung Kim;Hye Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.826-837
    • /
    • 2021
  • Immunoglobulin G4-related disease (IgG4-RD) is a chronic inflammatory condition involving multiple organs, including the salivary or lacrimal glands, orbit, pancreas, bile duct, liver, kidney, retroperitoneum, aorta, lung, and lymph nodes. It is histologically characterized by tissue infiltration with lymphocytes and IgG4-secreting plasma cells, storiform fibrosis, and obliterative phlebitis. In the thoracic involvement of IgG4-RD, mediastinal lymphadenopathy and perilymphangitic interstitial thickening of the lung are the most common findings. Peribronchovascular and septal thickening and paravertebral band-like soft tissue are characteristic findings of IgG4-RD. Other findings include pulmonary nodules or masses, ground-glass opacity, alveolar interstitial thickening, pleural effusion or thickening, mass in the chest wall or mediastinum, and arteritis involving the aorta and coronary artery. Radiologic differential diagnosis of various malignancies, infections, and inflammatory conditions is needed. In this review, we describe the imaging findings of IgG4-RD and the radiologic differential diagnoses in the thorax.

Extremely Rare CT and MRI Findings of Peritoneal Leiomyoma Mimicking Hepatic Mass: A Case Report (매우 드문 간종괴로 오인된 복막 평활근종의 CT 및 MRI 소견: 증례 보고)

  • Jonghun Woo;Seo-Youn Choi;Hee Kyung Kim;Ji Eun Lee;Min Hee Lee;Sanghyeok Lim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.946-951
    • /
    • 2023
  • Leiomyoma is a common benign tumor from smooth muscle cells, mostly in the uterus. Peritoneal leiomyomas (PLs) are extremely rare and mostly reported as disseminated peritoneal leiomyomatosis. However, to the best of out knowledge, radiologic findings of isolated PL are not reported in English literature. Herein, we introduce the radiologic findings of PL mimicking hepatic mass in a 34-year-old female. CT showed a mass with curvilinear heterogeneous enhancement at the liver's peripheral area. On MRI, the mass showed gradual and heterogeneous enhancement on gadoxetic acid-enhanced MRI and diffusion restriction. The radiologic diagnosis was a benign hepatic tumor, such as degenerated hemangioma, adenoma, and inflammatory myofibroblastic tumor; however, the mass was diagnosed as PL pathologically.

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

Evaluation of the Solitary Pulmonary Nodule by Spiral Computed Topography with Contrast Enhancement (고립성 폐결절의 감별에 있어서 나선형 흉부 전산화 단층촬영시 조영증강의 의의)

  • Song, Kwang Seon;Shin, Kye Chul;Yong, Suk Joong;Ryu, Jeong Seon;Kang, Sin Goo;Kim, Chong Ju;Sung, Ki Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.519-526
    • /
    • 1996
  • Background : Clinical and Radiographic studies to differentiate benign from malignant pulmonary nodules have previously focused on clinical status and the morphologic and the computed tomographic attenuation characteristics of the lung nodules. Distinctive differences in the vascularity and pathophysiology of malignant versus benign pulmonary nodules were identified. We evaluated the diagnostic method for differentiating malignant from benign solitary pulmonary nodule by contrast enhancement on the spiral CT. Method : Sixteen patients with solitary pulmonary nodule were examined(Tuberculoma 8, primary lung cancer 8). Serial thin section on the spiral CT was performed before and after(45second, 2min, 5min) the onset of the injection of 100mL of nonionic contrast material(2mL/sec). Results : There was no difference in size of nodule and pre-contrast CT number (Hounsfield unit) between benign and malignant nodules. At forty-five second after the onset of the injection, malignant neoplasms($19.6{\pm}7.9$ HU) enhanced significantly more than tuberculomas($4.9{\pm}9.4$ HU, p=0.008). At 2minute and 5 minute after, malignant neoplasms($34.0{\pm}19.2$HU, $34.0{\pm}15.4$HU) enhanced significantly more than tuberculomas ($6.7{\pm}9.7$HU, p=0.007 and $7.7{\pm}11.5$HU, p=0.011). On cut-off value 20HU(contrast enhancement) 2minute after the injection of contrast media, sensitivity was 87% and specificity was 87%. No correlation between the contrast enhancement and size of the nodules was observed. Conclusion : Studies with the use of an intravenously administered noniodinated contrast medium in examining the enhancement properties of lung nodules was performed. The contrast enhancement was useful in differential diagnosis of solitary pulmonary nodules.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Long Term Results of Radiation Therapy in Early Glottic Cancer (초기 성문암의 방사선치료: 장기 추적결과)

  • Kim, Jin-Hee;Byun, Sang-Jun
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • Purpose: This study was designed to evaluate long-term results in terms of failure, survival and voice preservation after radiation therapy for early glottic cancer. Materials and Methods: From February 1988 to December 2003, 70 patients with early glottic cancer were treated with radiation therapy at Keimyung University Dongsan Medical Center. Patient age distribution was from 39 to 79 years, with a median age of 62 years. All patients had squamous cell carcinoma. According to the TNM stage, 58 patients had stage I disease, 12 patients had stage II disease; 67 patients were male. The laryngeal area was irradiated with the use of bilateral opposing fields with/without a wedge filter with 6 MV photons at a total dose of $54{\sim}70.2$ Gy in $1.8{\sim}2.2$ Gy fractions over $6{\sim}8$ weeks. We delivered a median radiation dose of 60 Gy for stage I patients and a median radiation dose of 66 Gy for stage II patients. Salvage surgery was performed in patients with local recurrence. The voice preservation rate was analyzed after all treatments including salvage surgery. Follow-up periods were from 13 to 180 months, with a median follow-up period of 77.5 months. The survival rate was analyzed by the use of the Kaplan Meier method and log rank test. A comparison of two groups was performed with the use of the chi-squared test. Results: The local control rate was 98.5% (69/70). The five-year-overall survival rate was 93.9%. The five-year disease free survival rate (5YDFS) was 84.1% and the 5YDFS after radiation and salvage surgery was 92.8%. According to stage, the 5YDFS was 93.1% and 91.7% for stage I and stage II respectively. Thirteen patients (18.5%) had local failure with 24 months of median time to local failure and nine patients received salvage surgery; however, four patients were lost to follow-up after a diagnosis of recurrence. Only two patients died due to a distant metastasis at 33 months and 71 months after radiation therapy, respectively. Nine patients died due to other diseases with a median time of 73 months. There were no severe acute or chronic complications after radiation therapy. Voice preservation was ultimately achieved in 88.5% (62/70) of patients. Conclusion: We considered that radiation therapy was effective and we achieved excellent survival and voice preservation in early laryngeal cancer. The use of radiation therapy should be the first choice for the treatment of early glottic cancer.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.