• Title/Summary/Keyword: 간접측정법

Search Result 213, Processing Time 0.023 seconds

Historical Development of Nutrient and Calorimetry and Expired Gas Analysis Indirect Calorimetry (영양소와 열량측정법의 발달과정 및 간접 열량 측정법)

  • Yoon, Byung-Kon;Kim, Jong-Won;Kim, Do-Yeon
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1159-1165
    • /
    • 2010
  • Indirect calorimetry is the measurement of the amount of heat generated in an oxidation reaction by determining the intake or consumption of oxygen or by measuring the amount of carbon dioxide or nitrogen released and translating these quantities into a heat equivalent. In the last 20 years there has been significant development in both laboratory and computerized metabolic systems used in indirect calorimetry. In addition, there has been increased use of breath-by-breath EGAIC. Several researchers have suggested that breath-by-breath analysis, because of their practicality, could fulfill this need for a valid and reliable expired gas analysis indirect calorimetry instrument. It was hoped this investigation would determine the best validation for a precise measurement of breath-by-breath expired gas analysis indirect calorimetry. The problem with the available research is that few studies have examined the validity and reliability of all these different systems for breath-by-breath expired gas analysis indirect calorimetry. Therefore, there is a need to find out the most valid, reliable, and precise measurement of the breath-by-breath expired gas analysis indirect calorimetry.

A Study on Shear Stress Distribution in a Open Channel (개수로에서의 바닥전단응력 분포 분석)

  • Kim, Min Gyu;Kang, Kimchhun;Oh, Jun Oh;Park, Jae Hyeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.445-445
    • /
    • 2016
  • 급변하는 개수로 흐름에서 발생하는 바닥전단응력의 분포는 하천구조물 설계에 있어 매우 중요한 요소이다. 하천 구조물 중 호안에 대한 하천설계기준 '설계편 제 24장 호안'에는 호안 설계에 대한 일반적인 사항이 제시 되어 있으나, 구체적인 소류력 또는 유속에 대한 기준, 각 호안공법들의 안정성을 평가하기 위한 시험법 등에 대한 구체적인 기준이 부족한 상황이다. 소류력 측정방법에는 간접측정법과 직접측정법이 있다. 간접측정법에는 Reach-Average공식, Reynolds Stress, TKE공식 (Turbulent Kinetic Energy)이 있고 직접측정법에는 Shear Meter, Preston Tube 등이 있다. 본 연구에서는 바닥전단응력을 직접 측정할 수 있는 1차원 소류력 측정장치를 개발하고, 최대유속 5m/s 가변형 고속수로 실험을 통하여 Reach-Average 공식, Reynolds Stress, TKE 공식으로 산정한 바닥전단응력 값과 1차원 소류력 측정장치 값을 비교 분석하였다. 실험케이스는 총 3개로, 22.42???, 30.00???, 41.00??? 유량을 사류이면서 난류인 상태로 실험을 수행하였다. 분석 결과, 본 연구에서 개발한 1차원 소류력 측정장치의 측정값은 TKE공식과 약 2.3% 차이가 났으며, Reach-Average공식과 약 8.1%, Reynolds Stress는 약 22.1% 차이가 났다. 즉, 본 연구에서 개발한 1차원 소류력 측정장치는 유속 범위(1m/s ~1.6m/s )에서 TKE공식을 이용한 바닥전단 응력과 가장 근사하게 나타나는 것으로 분석되었다.

  • PDF

An Assessment of Factory Odor Evaluation with Indirect Olfactory Method (간접관능법에 의한 사업장 발산악취 평가)

  • 김학민;정의석;김선규;김선태;박주철
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.183-184
    • /
    • 2002
  • 악취현상 평가방법은 냄새유발물질의 농도를 정량적으로 분석하는 화학성분분석법과 복합취기물질에 의란 감각수준을 다수의 악취판정인이 평가하는 관능측정법으로 대별할 수 있다. 특히, 관능측정법의 경우 자극의 세기를 표현하는 직접관능법과 최소냄새감지한계회석배수를 구하는 간접관능법으로 구분할 수 있으며, 환경악취현상을 객관적으로 평가하기 위해서는 성분분석과 감각수준을 평가하는 두 방법에 의한 측정결과를 종합적으로 고려하는 것이 타당한 것으로 알려져 있다. (중략)

  • PDF

Spectrum Analyzer를 통한 미세 방전 플라즈마 밀도측정

  • Jo, Tae-Hun;Yun, Myeong-Su;Park, In-Gyu;Yu, Ha-Jin;Choe, Eun-Ha;Jo, Gwang-Seop;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.136-136
    • /
    • 2010
  • 일반적인 플라즈마의 밀도측정에는 랑뮤어(Langmuir)탐침법이 보편적으로 사용되고 있다. 그러나 LCD(Liquid Crystal Display)나 PDP(Plasma Display Panel) 등 미세 방전 플라즈마는 이러한 방법으로는 측정이 너무 어려워서 잘 사용되지 않고 있다. 그래서 이러한 경우 간접측정 방법이 사용되고 있다. 본 연구에서는 알려진 간접 측정방법과는 다른 방식인 spectrum analyzer를 사용하여 측정해 보았다. LCD에서 사용되는 BLU(Back Light Unit)lamp와 PDP panel을 각각 측정하여 기존의 간접측정 방법의 결과와 비교해 보았다.

  • PDF

An Approach to Measure Anthropometric Data of Simulated Human Hand Using Photogrammetry (시뮬레이션 환경에서 사진측량기법을 이용한 손 치수 측정 방법에 대한 연구)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.5
    • /
    • pp.511-517
    • /
    • 2016
  • Anthropometric data of the hand is one of the important issues for the product design related with hand and manual operation in terms of user-centered design. Direct measurement, which traditionally uses anthropometric measuring tool, has a few disadvantages in cumulation of measuring time, possible errors in raw data, doubtful reliability between inspectors. Newly introduced 3D scanning technology overcomes those disadvantages; however, another disadvantages, such as, hight cost and immovability, have been introduced. In this study, photogrammetric approach was introduced for the measurement of anthropometric data in hand. In order to minimize the possibility of error during direct and indirect measurement, a simulated object was used and effectiveness of photogrametric measurement was confirmed for the collection of anthropometric data in hand.

Ultrasonic Nondestructive On-Site Evaluation of Decks in-Service (초음파 비파괴시험법을 이용한 데크재의 현장평가)

  • Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.4
    • /
    • pp.486-493
    • /
    • 2015
  • The ultrasonic nondestructive test (NDT) was applied to deck in-service to inspect and evaluate the performance of decking materials using ultrasonic pulse velocity. First, the measuring method between direct and indirect method according to transducer arrangement was studied. Second, the ultrasonic pulse velocity of decks in-service was compared with the passage of time. Finally, the change of ultrasonic pulse velocity was evaluated to expect service life of decking materials. The results of comparison between direct and indirect method was statistically insignificant and the ratio of direct to indirect method was 1.02. 1.05 respectively. The ultrasonic pulse velocity of decks in-service was decreased as the passage of time and the linear relationship in the ultrasonic pulse velocity to passage of time was found. From the results, The ultrasonic NDT will be helpful as an efficient method of on-site management of decks in-service.

한국 제조업에서의 환경규제와 생산성감소 - 인과추정법(因果推定法)을 통하여 -

  • Lee, Myeong-Heon
    • Environmental and Resource Economics Review
    • /
    • v.5 no.2
    • /
    • pp.279-290
    • /
    • 1996
  • 정부의 환경규제로 인하여 한국 제조업의 기업들이 공해방지시설을 의무적으로 설치해야할 경우, 이는 생산비증가와 신규투자의 위축 및 생산요소간 조합비율에 영향을 미침으로써 직 간접적으로 생산성의 감소를 초래한다. 본 연구에서는 인과추정법(因果推定法)으로 측정한 그레이 (Gray, 1987)의 모형을 통하여 환경규제가 한국 제조업의 생산성에 미치는 효과를 측정하였다. 측정결과, 규제로 인하여 연평균 0.58퍼센트 포인트만큼의 생산성감소효과가 있었다. 여기에는 생산성증가율 계산상의 '측정효과(測定效果)'만 존재하고 생산과정의 제약, 신규투자의 위축, 다른 생산요소의 생산성감소로 인하여 총생산성이 감소되는 '실질효과(實質效果)'는 발생하지 않았다.

  • PDF

Immune Reaction to Infection by Malassezia pachydercatis in Canine Ezternal Ear Canals (개 외이도내 Malassezia pachydercatis 감염에 대한 면역 반응)

  • 이진희;오태호;한홍율;조상내
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.130-139
    • /
    • 1996
  • Malassezia pachydercatis균은 개 외이염의 주된 원인균으로 알려져 있으나, 그 감염률은 지역에 따라 많은 차이가 있다. 그러나 그 기병론적인 역할에 대해서는 아직 명확히 밝혀지지 않았다. 이에 본문에서는 국내에서 사육되는 개의 외이염에서 Malassezia pachydercatis 균의 분리율을 조사하고, Malassezia pachydercatis에 대한 혈중 항체와 외이염과의 연관성을 밝혀 Malassezia pachydercatis에 의한 외이염 진단을 위한 도구로서 간접 ELISA 법의 유용성을 평가해 보고자 본 연구를 수행하였다. 총 112두 중, 외이염에 감염된 개 44두와 정상견 68두를 대상으로, 심부외이도에서 취한 가검물을 배양검사하였고, Malassezia pachydercatis 항원에 대한 혈청내 IgG와 IgM 역가를 간접 ELISA법에 의해 측정하였다. 살아있는 Malassezia pachydercatis 균을 3두의 정상견 외이도에 접종하여 Malassezia pachydercatis 균의 실험적 감염에 대한 조직병리학적 소견, 조직내 침투 정도, 그리고 접종 후 시간경과에 따른 IgG와 IgM의 혈중 역가변화를 측정하였다. Malassezia pachydercatis 균은 외이염이 있는 개 귀에서 가장 높게 분리(50.0%)되었고, 정상귀에서는 낮게 분리(6.3%)되었다. Malassezia pachydercatis 항원을 이용한 간접 ELISA 법 진단에서, Malassezia pachydercatis 양성배양인 외이염 개체에서 IgG와 IgM에 대한 민감도는 각각 41.7%, 20.8%이었고 특이도는 88.2%, 85.2% 이었다. 실험적으로 Malassezia pachydercatis 를 접종한 3두중 1두에서만 조직병리학적 변화와 모낭에 Malassezia pachydercatis 균체가 확인되었으며, IgG와 IgM 혈중역가도 유의성 있게 증가하였다. 국내에서 사육되는 개 외이염의 주된 원인균은 Malassezia pachydercatis 균이었고 이 균의 혈중항체는 유의성 있게 증가하였으며(p<0.005), 간접 ELISA법은 Malassezia pachydercatis 에 의한 개외이염의 유용한 진단도구임을 증명하였다.

  • PDF