Browse > Article
http://dx.doi.org/10.5352/JLS.2010.20.8.1159

Historical Development of Nutrient and Calorimetry and Expired Gas Analysis Indirect Calorimetry  

Yoon, Byung-Kon (Department of Special Physical Education, Dong-Eui University)
Kim, Jong-Won (Department of Physical Education, Pusan National University)
Kim, Do-Yeon (Department of Physical Education, Pusan National University)
Publication Information
Journal of Life Science / v.20, no.8, 2010 , pp. 1159-1165 More about this Journal
Abstract
Indirect calorimetry is the measurement of the amount of heat generated in an oxidation reaction by determining the intake or consumption of oxygen or by measuring the amount of carbon dioxide or nitrogen released and translating these quantities into a heat equivalent. In the last 20 years there has been significant development in both laboratory and computerized metabolic systems used in indirect calorimetry. In addition, there has been increased use of breath-by-breath EGAIC. Several researchers have suggested that breath-by-breath analysis, because of their practicality, could fulfill this need for a valid and reliable expired gas analysis indirect calorimetry instrument. It was hoped this investigation would determine the best validation for a precise measurement of breath-by-breath expired gas analysis indirect calorimetry. The problem with the available research is that few studies have examined the validity and reliability of all these different systems for breath-by-breath expired gas analysis indirect calorimetry. Therefore, there is a need to find out the most valid, reliable, and precise measurement of the breath-by-breath expired gas analysis indirect calorimetry.
Keywords
Indirect calorimetry; heat equivalent; breath-by-breath; validity; reliability;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Rosenbaum, A., C. Kirby, and P. H. Breen. 2007. New metabolic lung simulator: development, description, and validation. J. Clin. Monitor. Comp. 21, 71-82.   DOI
2 Storer, T. W., T. J. Bunnell, A. Hand, and S. Grant. 1995. Validation of a new metabolic measurement cart. Int. J. Sports Med. 16, 101.
3 Wasserman, K., J. E. Hansen, D. Y. Sue, B. J. Whipp, and R. Casaburi. 1994. Principles of exercise testing and interpretation. 2nd Eds. Philadelphia, PA: Lea & Febiger.
4 Wilmore, J. H. and D. L. Costill. 1974. Semi-automated systems approach to the assessment of oxygen uptake during exercise. J. Appl. Physiol. 36, 618-620.
5 Yates, J. W. and M. G. Cullum. 2001. The validation of a metabolic cart without human subjects. Med. Sci. Sports Exerc. 33(Suppl. 5), S299.
6 Huszczuk, A., B. J. Whipp, and K. A. Wasserman. 1990. Respiratory gas exchange simulator for routine calibration in metabolic studies. Eur. Respir. 3, 465-468.
7 Katch, V. L., S. S. Sady, and P. Freedson. 1982. Biological variability in maximum aerobic power. Med. Sci. Sports Exerc. 14, 21-25.   DOI
8 Lusk, G. 1909. The elements of the science of nutrition, 2nd ed. Philadelphia, PA: W. B. Saunders company.
9 Macfarlane, D. J. 2001. Automated metabolic gas analysis systems. Sports. Med. 32, 841-861.
10 Matarese, L. E. 1997. Indirect calorimetry: Technical aspects. J. Amer. Dietet. Assoc. 97(Suppl. 2), S154-S160.   DOI
11 McClave, S. A. and H. L. Snider. 1992. Use of indirect calorimetry in clinical nutrition. Nutr. Clin. Pract. 7, 207-221.   DOI
12 Meyer, T., T. Georg, C. Becker, and W. Kindermann. 2001. Reliability of gas exchange measurements from two different spiroergometry systems. Int. J. Sports Med. 22, 593-597.   DOI
13 Noguchi, H., Y. Ogushi, I. Yoshiya, N. Itakura, and H. Yamabayashi. 1982. Breath-by-breath $VCO_{2}$ and $VO_{2}$ require compensation for transport delay and dynamic response. J. Appl. Physiol. 52, 79-84.
14 Pinnington, H. C., P. Wong, J. Tay, D. Green, and B. Dawson. 2001. The level of accuracy and agreement in measures of $F_{E}O_{2}$, $F_{E}CO_{2}$ and $V_{E}$ between the Cosmed K4b2 portable, respiratory gas analysis system and a metabolic cart. J. Sci. Med. Sport 4, 324-325.   DOI
15 Proctor, D. N. and K. C. Beck. 1996. Delay time adjustments to minimize errors in breath-by-breath measurement of $VO_{2}$ during exercise. J. Appl. Physiol. 81, 2495-2499.
16 Carter, J., and A. E. Jeukendrup. 2002. Validity and reliability of three commercially available breath-by-breath respiratory systems. Eur. J. Appl. Physiol. 86, 435-441.   DOI
17 Crouter, S. E., A. Antczak, J. R. Hudak, D. M. DellaValle, and J. D. Haas. 2006. Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems. Eur. J. Appl. Physiol. 98, 139-151.   DOI
18 Cullum, M. G., H. Welch, and J. W. Yates. 1999. Evaluation of an automated metabolic cart compared to Douglas bag measurement of $VO_{2}$. Med. Sci. Sports Exerc. 31, S302.
19 Davies, E. E., H. L. Hahn, S. G. Spiro, and R. H. Edwards. 1974. New technique for recording respiratory transients at the start of exercise. Resp. Physiol. 20, 69-79.   DOI
20 Reid, C. L. and G. L. Carlson. 1998. Indirect calorimetrya review of recent clinical applications. Curr. Opin. Clin. Nutr. 1, 281-286.   DOI
21 Reybrouck, T., F. Deroost, and V. Hauwaert. 1992. Evaluation of breath-by-breath measurement of respiratory gas exchange in pediatric exercise testing. Chest 102, 147-152.   DOI
22 Rietjens, C. J. W. M., H. Kuipers, A. D. M. Kester, and H. A. Keizer. 2001. Validation of a computerized metabolic measurement system (Oxycon-$Pro^{{\circledR}}$) during low and high intensity exercise. Int. J. Sports Med. 22, 291-294.   DOI
23 Robergs, R. A. and A. F. Burnett. 2003. Methods used to process data from indirect calorimetry and their application to $VO_{2}$max. J. Exerc. Physiol. Online 6, 44-57.
24 Robergs, R. A. and S. J. Keteyian. 2003. Fundamentals of exercise physiology for fitness, performance, and health. 2nd eds. New York: McGraw-Hill.
25 Robergs, R. A., and S. O. Roberts. 1997. Exercise Physiology: Exercise, performance, and clinical applications. St. Louis, MO: Mosby-Year Book, Inc.
26 Gore, C. J., R. J. Clark, N. J. Shipp, G. E. Van Der Ploeg, and R. T. Withers. 2003. CPX/D underestimates $VO_{2}$ in athletes compared with an automated Douglas bag system. Med. Sci. Sports Exerc. 35, 1341-1347.   DOI
27 da Rocha, E. E., V. G. F. Alves, and R. B. V. da Fonseca. 2006. Indirect calorimetry: methodology, instruments and clinical application. Curr. Opin. Clin. Nutr. 9, 247-256.   DOI
28 Foss, O. and J. Hallen. 2005. Validity and stability of a computerized metabolic system with mixing chamber. Int. J. Sports Med. 26, 569-575.   DOI
29 Gore, C. J., P. G. Catcheside, S. N. French, J. M. Bennett, and J. Laforgia. 1997. Automated $VO_{2}$max calibrator for open-circuit indirect calorimetry systems. Med. Sci. Sports Exerc. 29, 1095-1103.   DOI   ScienceOn
30 Hodges, L. D., D. A. Brodie, and P. D. Bromley. 2005. Validity and reliability of selected commercially available metabolic analyzer systems. Scand. J. Med. Sci. Sport 15, 271-279.   DOI
31 Bassett, D. R. Jr, E. T. Howley, D. L. Thompson, G. A. King, S. Strath, J. E. McLanghlin, and B. P. Brian. 2001. Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system. J. Appl. Physiol. 91, 218-224.
32 Ainslie, P. N., T. Reilly, and K. R. Westerterp. 2003. Estimating human energy expenditure: a review of techniques with particular reference to doubly labeled water. Sports Medicine 33, 683-698.   DOI
33 Barnard, J. P. M. and J. W. Sleigh. 1995. Breath-by-breath analysis of oxygen uptake using the Datex Ultima. British J. Anaesthesia 74, 155-158.   DOI
34 Bassett, D. R. Jr, E. T. Howley, D. L. Thompson, G. A. King, S. Strath, J. E. McLanghlin, and B. P. Brian. 2001. Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system. J. Appl. Physiol. 91, 218-224.
35 Brandi, L. S., R. Bertolini, and M. Calafa. 1997. Indirect calorimetry in critically ill patients: clinical applications and practical advice. Nutrition 13, 349-358.
36 Brooks, G. A., T. D. Fahey, T. P. White, and K. M. Baldwin. 2000. Exercise physiology. 3rd Eds. Human Bioenergetics and its applications. Mountain View, CA: Mayfield Publishing Company.