Ultrasonic Nondestructive On-Site Evaluation of Decks in-Service

초음파 비파괴시험법을 이용한 데크재의 현장평가

  • 오세창 (대구대학교 생명환경대학 산림자원학과)
  • Received : 2015.04.03
  • Accepted : 2015.05.13
  • Published : 2015.07.25

Abstract

The ultrasonic nondestructive test (NDT) was applied to deck in-service to inspect and evaluate the performance of decking materials using ultrasonic pulse velocity. First, the measuring method between direct and indirect method according to transducer arrangement was studied. Second, the ultrasonic pulse velocity of decks in-service was compared with the passage of time. Finally, the change of ultrasonic pulse velocity was evaluated to expect service life of decking materials. The results of comparison between direct and indirect method was statistically insignificant and the ratio of direct to indirect method was 1.02. 1.05 respectively. The ultrasonic pulse velocity of decks in-service was decreased as the passage of time and the linear relationship in the ultrasonic pulse velocity to passage of time was found. From the results, The ultrasonic NDT will be helpful as an efficient method of on-site management of decks in-service.

설치된 데크재에 대한 성능을 평가하기 위하여 초음파 비파괴시험법을 사용하였다. 먼저 3종류의 데크재에 대해 트랜스듀서의 배치에 따른 직접법과 간접법간의 측정방법간의 차이를 검증하였으며 두 번째로 설치된 데크재의 사용시간의 경과에 따른 초음파속도를 측정 비교하였다. 마지막으로 데크재의 사용수명을 파악하기 위하여 사용시간의 경과에 따른 초음파속도의 변화를 조사하였다. 시험결과 직접법과 간접법간의 측정방법간의 차이는 없는 것으로 나타났으며 직접법에 대한 간접법의 비율은 1.02와 1.05로 각각 나타났다. 설치된 데크재에서 시간의 경과에 따라 초음파 속도는 감소하였으며 이들 간의 관계는 선형으로 나타났다. 시험결과로부터 초음파 비파괴시험법은 설치된 데크재의 유지보수에 관한 효율적인 수단이 될 수 있을 것으로 생각된다.

Keywords

References

  1. Kim, G.M., Lee, I.C., Lee, J.J. 2005. Detection of internal wood decay using Ultrasonic CT. Proceedings of Korea Wood Science and Technology 2005: 74-78.
  2. Lee, S.J., Lee, S.D., Pang, S.J., Kim, C.K., Kim, K.M., Kim, K.B., Lee, J.J. 2013, Indirect detection of internal defects in wooden rafter with ultrasound. Journal of Korean Wood Science & Technology 41(2): 164-172 https://doi.org/10.5658/WOOD.2013.41.2.164
  3. Linan, C.R., Hita, R.P., Cozar, G. 2001. Study, diagnosis and rehabilitation of the wooden slabs of two palace houses in Seville. in 3er Seminario Internacional sobre construcciones Historicas: 811-820. Portugal.
  4. Lourenco, P.B., Feio, A.O., Machado, J.S. Chestnut wood in compression perpendicular to the grain:Non-destructive correlations for test results in new and old wood. Construction and Building Materials 21: 1617-1627.
  5. Machado, J.S., Palma, P., Simoes, S. 2009. Ultrasonic indirect method for evaluating clear wood strength and stiffness. in NDTCE '09 Non-Destructive Testing in Civil Engineering, Nante, France.
  6. Naik, T.R., Malhotra, V.M., Popvics, J.S. 2004. The ultrasonic pulse velocity method. in Handbook on Nondestructive Testing of Concrete 2nd edition. Ch. 8. CRC Press, LLC.
  7. Najafi, S.K., Ebrahimi, G., Behjati, S. 2008. Nondestructive evaluation of wood plastic composite using ultrasinic technique. Proceedings of DEFEKTOSKOPIE, Brno 2008: 87-94.
  8. Proceq. SA. 2014. Pundit lab operating instructions.
  9. Son, D.W., Lee, D.H. 2004. Wood decay detection by. Journal of the Korea Wood Science and Technology 32(4): 74-81.
  10. Teder, M., Pilt, K., Miljan, M., Lainurm, M., Kruuda, R. 2011, Overview of some non destructive method for In Situ assessment of structural timber. 3rd International Conference Civil Engineering 2011 Proceedings II Materials and structures.