• Title/Summary/Keyword: 간격

Search Result 9,256, Processing Time 0.033 seconds

Evaluation of Optimum Spacing between Anchor Bodies of Distributive Compression Anchor Using Numerical Simulation (수치해석을 이용한 압축 분산형 앵커의 내하체 최적 간격 산정)

  • Gu, Kyo-Young;Shin, Gyu-Bum;Chung, Choong-Ki;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.29-39
    • /
    • 2019
  • Load distributive compression anchors distribute the compressive stress in the grout and increase the pull-out capacity of the anchor by using multiple anchor bodies. In this anchor type, the spacing between the anchor bodies has a large influence on the stress in the grout. However, there are few researches about the spacing and there are no design standards. Therefore, the effect of the anchor body spacing on the grout stress was analyzed by performing finite element analyses. First, the applicability of the numerical modeling was verified by comparing with field test results of a compression anchor. Then, the parametric study was performed varying soil type, anchor body spacing, and load magnitude. The analysis results showed that the maximum compressive stress in the grout increased at the narrower spacing and the tensile stress developed at the wider spacing. Therefore, the optimum spacing was defined as the spacing, which prevents the superposition of compressive stresses and minimize the tensile stress. Finally, the optimum spacing was proposed according to the soil type and the load magnitude.

Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season (동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격)

  • Kim, Hye Min;Jeong, Hyeon Woo;Hwang, Hee Sung;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.8-13
    • /
    • 2022
  • This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.

Building a Model to Estimate Pedestrians' Critical Lags on Crosswalks (횡단보도에서의 보행자의 임계간격추정 모형 구축)

  • Kim, Kyung Whan;Kim, Daehyon;Lee, Ik Su;Lee, Deok Whan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1D
    • /
    • pp.33-40
    • /
    • 2009
  • The critical lag of crosswalk pedestrians is an important parameter in analyzing traffic operation at unsignalized crosswalks, however there is few research in this field in Korea. The purpose of this study is to develop a model to estimate the critical lag. Among the elements which influence the critical lag, the age of pedestrians and the length of crosswalks, which have fuzzy characteristics, and the each lag which is rejected or accepted are collected on crosswalks of which lengths range from 3.5 m to 10.5 m. The values of the critical lag range from 2.56 sec. to 5.56 sec. The age and the length are divided to the 3 fuzzy variables each, and the critical lag of each case is estimated according to Raff's technique, so a total of 9 fuzzy rules are established. Based on the rules, an ANFIS (Adaptive Neuro-Fuzzy Inference System) model to estimate the critical lag is built. The predictability of the model is evaluated comparing the observed with the estimated critical lags by the model. Statistics of $R^2$, MAE, MSE are 0.96, 0.097, 0.015 respectively. Therefore, the model is evaluated to explain the result well. During this study, it is found that the critical lag increases rapidly over the pedestrian's age of 40 years.

An Experimental Study on a Characteristics of Flow around Groynes for Groyne Spacing (수제 설치간격에 따른 수제주변 흐름특성에 관한 실험 연구)

  • Kang, Joon Gu;Yeo, Hong Koo;Roh, Young Sin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3B
    • /
    • pp.271-278
    • /
    • 2006
  • In design of groyne series, groyne spacing is a important factor and have an effect on not only the characteristics of backward and recirculation flow in groyne zone but also flow field in main channel. It is necessary study about flow pattern of recirculation zone and main channel that is a cause of bad change, local scour and bank erosion by groyne spacing. In this study, flow variation of groyne zone and main chanel for spacing of groynes were analyzed from the experiment results in order to offer a fundamental data that can be used to decide the proper groyne spacing. Experiments were conducted 12 cases for groyne spacing(L) by groyne length(l) rate and the velocity profile was measured using LSPIV and ADV. From the results, two vortex flows developed in recirculation zone for L/l=3~9 and three vortex flows developed over L/l=10. The velocity of backward flow in recirculation zone was decreased up to 20% over L/l=4. The velocity of main channel flow was increased from 1.3 to 2.0 times by groyne spacing and the rate of velocity increased by increasing groyne spacing. The maximum velocity occurred in 0.7~0.8 times of groyne spacing downstream of upper groyne.

Kissing of Sub-conductors due to Magnetic Forces in a 154 kV Bundled Overhead Transmission Line (154 kV 복도체 가공송전선로에서 전자력에 의한 소도체간 접촉)

  • Kim, Sang-Beom;Noh, Hee-Won;Kim, Young-Hong;Ko, Kwang-Man;Park, Jong-Hyuk;Kim, Sang-Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.383-389
    • /
    • 2016
  • Kissing of sub-conductors due to magnetic forces has been investigated in a 154 kV bundled overhead transmission line. With increasing ampacity of the conductors and enlarging the distance between spacers, lager magnetic force was measured. When the phase ampacity was 2,000 amps and the distance between two adjacent spacers was 68 m, for instance, the conductors became unstable and vibrated with a frequency of several herts. Furthermore, when the ampacity was 2,250 amps and the distance between spacers was 136 m, the two sub-conductors were contacted. Analysing the magnetic forces with distance of spacers, the safe distance of spacers to avoid contact of sub-conductors was presented. The change of the safe distance is discussed due to various parameters, such as residual stresses and wind pressures, in the real transmission lines.

An Experimental Study on the Stabilizing Effect of Piles against Sliding (사면에 설치된 억지말뚝의 활동억지효과에 대한 실험적 연구)

  • Hong Won-Pyo;Song Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.69-80
    • /
    • 2005
  • In order to investigate the stabilizing effect of piles against sliding, a series of model tests were carried out. The model apparatus was designed to perform the model test of slope reinforced by stabilizing piles. The instrumentation system was used to measure the deflection of stabilizing piles during slope failure. The stabilizing effect of the piles in a row with some interval ratio is larger than the isolated pile without interval ratio. Because the prevention force of piles in a row increased due to the soil arching effect between piles during slope failure. Especially, the maximum value of prevention ratio was presented at 0.5 of interval ratio. If the required prevention ratio is 1.1, the interval ratio must be installed from 0.5 to 0.8. Also, the stabilizing effect of piles against sliding is excellent at the interval ratio between 0.5 and 0.8. This value can be proposed as the criterion of the interval ratio between piles against slope failure.

Determining Optimal Aggregation Interval Size for Travel Time Estimation and Forecasting with Statistical Models (통행시간 산정 및 예측을 위한 최적 집계시간간격 결정에 관한 연구)

  • Park, Dong-Joo
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.3
    • /
    • pp.55-76
    • /
    • 2000
  • We propose a general solution methodology for identifying the optimal aggregation interval sizes as a function of the traffic dynamics and frequency of observations for four cases : i) link travel time estimation, ii) corridor/route travel time estimation, iii) link travel time forecasting. and iv) corridor/route travel time forecasting. We first develop statistical models which define Mean Square Error (MSE) for four different cases and interpret the models from a traffic flow perspective. The emphasis is on i) the tradeoff between the Precision and bias, 2) the difference between estimation and forecasting, and 3) the implication of the correlation between links on the corridor/route travel time estimation and forecasting, We then demonstrate the Proposed models to the real-world travel time data from Houston, Texas which were collected as Part of the Automatic Vehicle Identification (AVI) system of the Houston Transtar system. The best aggregation interval sizes for the link travel time estimation and forecasting were different and the function of the traffic dynamics. For the best aggregation interval sizes for the corridor/route travel time estimation and forecasting, the covariance between links had an important effect.

  • PDF

Comparison of Liver Damage in Bromobenzene-Daily Treated Rats with Every Other Day Treated Ones (랫드에 있어서 Bromobenzene의 격일 투여 시, 매일 투여한 경우와 간손상 정도의 비교)

  • 이상희;윤종국;조현국
    • Biomedical Science Letters
    • /
    • v.6 no.2
    • /
    • pp.101-107
    • /
    • 2000
  • To evaluate the effect of intervals of bromobenzene treatment on the liver damage, the bromobenzene (400 mg/kg, i.p.) was given to rats at either one day or two days interval at three times. All the experimental animals were sacrificed at 24 hours after the last injection. Liver morphological changes were observed under a light microscopic examination and liver functional changes were determined by the measurement of alaine aminotransferase (ALT) activity and hepatic malondialdehyde (MDA) content. The experimental to examine the cause of liver damage were cytochrome P45O, glutathione (GSH) content and glutathione S-transferase (GST) activities. The results are summarized as follows; Based on the liver morphological and functional findings, the daily bromobenzene-treated rats (ED) showed the more severe liver damage than every other day bromobenzene-treated rats (EOD). The hepatic cytochrome P45O content was higher in EOD group than that in ED group. And the increasing rate of hepatic GST activity and decreasing rate of GSH content to the control were higher in EOD group than that in ED group. In conclusion, the treatment of bromobenzene intermittently to the rats may lead to more reduced liver injury compared with the continuously treated animals when both cases are treated with the same dose and frequency, and it may be caused by the enhancement of bromobenzene metabolism.

  • PDF

Characteristics of Auto-ignition and Micro-explosion for Array of Emulsion Droplets (유화액적 배열에서의 자발화와 미소폭발의 특성)

  • Jeong, In-Cheol;Lee, Kyung-Hwan;Kim, Jae-Soo
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2007
  • The auto-ignition characteristics and combustion behaviors of one-dimensional array of water-in-fuel droplets suspended in a high temperature chamber have been investigated experimentally with various droplet spacing and number of droplets. The fuels used were pure n-decane and emulsified n-decane with water contents varied from 10% to 30%. All experiments have been performed at 920 K under the atmospheric pressure. The number of droplets in an array were fixed as 3 or 5 and its spacing was varied from 3 mm to 7 mm by 1mm interval. The imaging technique with a high-speed camera has been adopted to measure the ignition delay and flame life time. The micro-explosion behaviors were also observed. As the droplet array sparing increased, the ignition delay also increased regardless of water contents. However, the life time of droplet array decreased as the droplet spacing increased. The full combustion time in array of 3 droplets was found to be longer than that for 5 droplets case due to the longer ignition delay.

Treatment of Painful Rotator Interval Widening After Subcoracoid Decompression in Elite Archer - Case Report - (양궁 선수의 오구 충돌 증후군의 치료 후 발생한 회전근 간격의 손상에 대한 치료 - 증례 보고 -)

  • Park, Jin-Young;Lee, Seung-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.280-285
    • /
    • 2010
  • Purpose: Coracoid impingement syndrome refers to subscapularis impingement between the coracoid process and lesser tuberosity of the humerus, and pain may occur when the arm is positioned in forward flexion, internal rotation and adduction. This position is common for archers. Material and methods: A female archer with coracoid impingement syndrome that was uncontrolled by conservative therapy underwent arthroscopic subcoracoid decompression. At the 20th postoperative month of follow up, she complained of painful rotator interval widening and so she underwent arthroscopic rotator interval plication. Results: At the postoperative 6th month of follow up after the second operation, she showed no pain and good functional results, and she returned to competing as an archer. Conclusion: We have reported here on a case of successful treatment of painful rotator widening after subcoracoid decompression in an elite archer.