• Title/Summary/Keyword: 각 진폭

Search Result 357, Processing Time 0.03 seconds

Acoustic Scattering Characteristics of the Sea Bottom ( 1 ) (해저의 초음파 산란 특성에 관한 연구 ( I ))

  • Lee, Dae-Jae;Sin, Hyeong-Il;Park, Jung-Hui
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.51-56
    • /
    • 1990
  • The authors carried out an experiment to investigate the echo fluctuations from ocean bottom due to ship's motion. The bottom echoes was continuously measured, by using a 50 kHz Echo sounder on board of the ship being at anchor under the sea condition of 15 knots in wind velocity and approximately 2 meters in wave height, to extract the information about the pulse stretching and the ship's motion from the first return and the second return. A data acquisition system was used to record digitally the envelope of the echoes, and the analysis was applied to the echo data collected from the continental shelf in the South China Sea. The results obtained can be summarized as follows: 1. The equivalent pulse width of the second return echoes from ocean bottom was 2.4 times longer than that of the first return echoes. 2. The echo peak values of the first return fluctuated markedly than that of the second return and was shown to be extremely sensitive to small change in ship's motion. 3. Energy target strength and peak target strength of the sandy-mud bottom were -13.4 dB and -14.6 dB, respectively.

  • PDF

Study on Phase-Amplitude Characteristics in a Simplex Swirl Injector with Low Frequency Range (저주파 압력섭동 범위 내에서의 단일 스월 인젝터의 진폭-위상 특성 연구)

  • Khil, Tae-Ock;Chung, Yun-Jae;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.2
    • /
    • pp.19-28
    • /
    • 2010
  • Generally, combustion instability is generated by the mutual coupling between the heat release and the acoustic pressure in the combustor. On the occasion, the acoustic pressure generates the oscillation of the mass flow rate of propellant injected from injector, and this oscillation again affects combustion in the combustor. So, the dynamic characteristics of the injector have been studied to control combustion instability using injector itself in Russia from 1970's. In order to study injector dynamics, a mechanical pulsator for forced pressure pulsation is produced and the method to quantify the mass flow rate of the propellant that is oscillating at the exit of the injector is developed. With the pulsator and the method, pulsating values of the mass flow rate, pressure, liquid film thickness, and axial velocity generated at the exit of the simplex swirl injector are measured in real time. And phase-amplitude characteristics of each parameter are analyzed using these pulsating values acquired at the exit of the simplex swirl injector.

Study on the limitation of AVO responses shown in the seismic data from East-sea gas reservoir (동해 가스전 탄성파 자료에서 나타나는 AVO 반응의 한계점에 대한 고찰)

  • Shin, Seung-Il;Byun, Joong-Moo;Choi, Hyung-Wook;Kim, Geon-Deuk;Ko, Seung-Won;Seo, Young-Tak;Cha, Young-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.107-112
    • /
    • 2008
  • In the case of the deep reservoirs like the gas reservoirs in the East-sea, it is often difficult to observe AVO responses in CMP gathers. Because the reservoir becomes more consolidated as its depth deepens, P-wave velocity does not decrease significantly when the pore fluid is replaced by the gas. In this study, we analyzed the effects of Poisson's ratio difference on AVO response with a variety of Poisson's ratios for the upper and lower layers. The results show that, as the difference in Poisson's ratio between the upper and lower layers decreases, the change in the reflection amplitude with incidence angle decreases. To consider the limitation of AVO responses shown in the gas reservoir in East-sea, the velocity model was made by simulation Gorae V structure with seismic data and well logs. The results of comparing AVO responses observed from the synthetic data with theoretical AVO responses calculated by using material properties show that the amount of the change in reflection amplitude with increasing incident angle is very small when the difference in Poisson's ratio between the upper and lower layers is small. In addition, the characteristics of AVO responses were concealed by noise or amplitude distortion arisen during preprocessing. To overcome such limitations of AVO analysis of the data from deep reservoirs, we need to acquire precisely reflection amplitudes in data acquisition stage and use processing tools which preserve reflection amplitude in data processing stage.

  • PDF

Contrast Sensitivity as a function of spatial frequency by using polarization (편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계)

  • Kim, Young-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2000
  • It was to adjust the luminance of light by the rotation angle of the polarizes and analyzer. The luminance value Lmax, Lmin of Contrast Sensitivity could be obtained from the rotation angle ${\theta}_m$ of the average luminance($L_m$), the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the maximum and the minimum's amplitude. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ We obtained the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the polarizes and analyzer from the rotation angle ${\theta}_m$ of the average luminance($L_m$) and the Contrast Sensitivity($C_s$). $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

Analysis of Second Order Adaptive IIR Band Pass Filters (2차 적응 IIR 대역 통과 필터의 해석)

  • 김정국;조복태;이재욱;서용수
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.247-250
    • /
    • 2003
  • 디지털 2차 적응 IIR 대역 통과 필터의 진폭 특성을 해석, 적응 계수와 입력 신호의 중심 주파수 그리고 극의 각과의 관계를 해석하고, 적응 계수의 경계를, 기존에 발표된 세 알고리즘을 예로 들어, 평가하였다.

  • PDF

Required Performance Analysis of Wavefront Distortion System against Monopulse Radar (모노펄스 레이더에 대한 전파왜곡 시스템의 요구 성능 분석)

  • Jang, Yeonsoo;Kim, Ghiback;Park, Jintae;Lee, Changhoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.577-580
    • /
    • 2016
  • One of the effective jamming methods to disturb monopulse radars is a wavefront distortion. Most well-known wavefront distortion is the cross eye technique which uses two transmitters. The cross eye can make angle error regardless of monopulse radar structure but high accuracies of phase and amplitude between two transmitters should be needed to make large angle error. Thus, the accuracies of phase and amplitude are essentially required performance parameters for implementation of wavefront distortion systems and the required values of accuracy is dependant on amount of angle error. In this paper, we derive expressions for minimum required values of phase difference and amplitude ratio according to amount of angle error and analyze the results.

The Characteristics of Acoustic Emission Signal under Composite Destruction on GFRP Gas Cylinder (유리섬유강화 복합재료 가스실린더의 복합재료 파괴시 발생하는 음향방출 특성)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal Ho;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.430-435
    • /
    • 2013
  • This study is investigation of the characteristics for acoustic emission signal generated by destruction on glass fiber bundles and specimen that was machined composite materials surrounding the outside of GFRP cylinder. The Amplitude of acoustic emission signal gets bigger as the cutting angle of knife increases. Accordingly, the number of hits in destruction of composite materials specimen have more in longitudinal direction (longitudinal direction to the glass fiber) than in hoop direction (horizontal direction to the glass fiber) while the amplitude of signals were bigger in hoop direction than longitudinal direction. It was found out that the amplitude of the glass fiber breakage is more than 40 dB and that the amplitude of signal for matrix crack was less than 40 dB because matrix crack signal was not observed when threshold value is 40 dB and matrix crack signal suddenly appered when threshold value is 32 dB. The slope of the amplitude is related to the acoustic emission source and the slope of the amplitude of the horizontal and vertical directions are 0.16 and 0.08. In particular, The slope of the amplitude of longitudinal direction breakage appear similar to the glass fiber breakage and therefore Acoustic emission source of longitudinal direction breakage is estimated the glass fiber breakage.

Abnormal Vibration of the Steam Turbine Shaft in 500 MW Class Coal-fired Power Plants (500 MW급 석탄화력발전소 증기터빈축 이상진동의 해결방안)

  • Ahn, Kwang-Min;Yoo, HoSeon
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.30-36
    • /
    • 2017
  • During the start-up of 500 MW class coal-fired power plant, abnormal shaft vibration was occurred on bearings installed on both side of high and intermediate pressure steam turbine. Shaft vibration was analyzed to investigate the reason and find the resolution, based on well-known theory in this study. Typical vibration characteristics which occur when rotating parts contact with stationary parts were observed at the analysis of frequency, amplitude and phase angle. The reason of abnormal vibration was assumed to be rub and internal parts wear was observed during repair period. As a result of applying low speed turning and balancing for resolution of abnormal vibration, balancing was more effective for rub removal. So balancing could be excellent resolution in the case of abnormal vibration which is similar to this study.

  • PDF

A Study on Measurement of Driver′s Sensibility due to Vehicular Speed Changes in a Graphic Simulator (화상 시뮬레이터에서 속도변화에 따른 운전자의 감성 측정에 관한 연구)

  • 정순철;민병찬;김유나;신미경;김철중
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.103-112
    • /
    • 2000
  • 본 연구는 Graphic simulator에서 자동차 속도 변화에 따른 운전자의 감성변화를 주관적 평가와 자율신경계의 반응을 통해 알아보고자 한다. 속도 변화는 정차(0km/h), 40km/h, 100km/h, 160km/h로 제시하였고, 건강한 10명의 피험자를 대상으로 심박변화율, 피부저항, 피부온도, 맥파 등의 생리신호를 측정하였다. 본 연구 목적에 적절한 속도 관련 어휘를 추출하여 각 속도에서의 주관적 감성 변화를 평가하였다. 또한, 각 속도 실험 전 후에 Simulator Sickness를 측정하여 Simulator Sickness가 실험 결과에 미치는 영향을 분석하였다. 속도가 증가함에 따라 긴장도와 쾌도가 증가한다는 주관적 평가 결과를 얻었다. 실험 전에 비해 실험 후의 Simulator Sickness 값은 증가하였지만 실험 전, 후의 통계적 차이는 관찰할 수 없었다. 속도 증가에 따라, 평균 R-R간격, 피부온도의 진폭은 감소하였고, 피부저항은 증가하였고, 맥파의 평균 진폭은 감소하였다. 그러므로 본 연구를 통해 Simulator Sickness의 큰 영향 없이 Graphic Simulator에서 속도의 증가에 따라 교감신경계가 활성화됨을 관찰할 수 있었고, 이는 실제 동적 환경에서 속도 변화에 따른 자율신경계의 반응 및 주관적 평가 결과와 일치하는 것이다. 향후 복합 감각 자극이 가능한 시뮬레이터가 구축이 될 것이고, 이를 통해 보다 현실감 있는 동적 환경 제시와 감성 측정이 가능할 것이다.

  • PDF

Analysis of Direction Finding Accuracy for Amplitude-Phase Comparison and Correlative Interferometer Method (진폭-위상 복합비교 기법과 상관형 위상비교 기법의 방향탐지 정확도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2016
  • In this paper, we present the direction finding accuracy of correlative interferometer method and amplitude-phase comparison method. Spiral antennas are used for amplitude-phase comparison method and blade antennas are used for correlative interferometer method. Those are made for uniform circular array (UCA) direction finding antenna systems. We simulate the accuracy of azimuth angle with 3 antennas UCA when SNR is 20 dB and baseline is 0.5 wave length. Correlative interferometer method has better accuracy than amplitude-phase comparison method.